CTRON-BDG-MIB CTRON-BDG-MIB DEFINITIONS ::= BEGIN -- ctron-bdg-mib.txt -- Part Number: 2170561-01 -- Revision: 1.01.01 -- Date: June 22, 1996 -- Cabletron Systems, Inc. -- 35 Industrial Way, P.O. Box 5005 -- Rochester, NH 03867-0505 -- (603) 332-9400 -- support@ctron.com -- This module provides authoritative definitions for Cabletron's -- enterprise-specific common MIB. -- -- This module will be extended, as required. -- -- Cabletron Systems reserves the right to make changes in -- specification and other information contained in this document -- without prior notice. The reader should consult Cabletron Systems -- to determine whether any such changes have been made. -- -- In no event shall Cabletron Systems be liable for any incidental, -- indirect, special, or consequential damages whatsoever (including -- but not limited to lost profits) arising out of or related to this -- document or the information contained in it, even if Cabletron -- Systems has been advised of, known, or should have known, the -- possibility of such damages. -- -- Cabletron grants vendors, end-users, and other interested parties -- a non-exclusive license to use this Specification in connection -- with the management of Cabletron products. -- Copyright August 95 Cabletron Systems IMPORTS OBJECT-TYPE FROM RFC-1212 bridge, layerMgmt FROM IRM-OIDS Counter FROM RFC1155-SMI; bridgeRev1 OBJECT IDENTIFIER ::= { bridge 1 } bdgdevice OBJECT IDENTIFIER ::= { bridgeRev1 1 } bdgPort OBJECT IDENTIFIER ::= { bridgeRev1 2 } filterDB OBJECT IDENTIFIER ::= { bridgeRev1 3 } trapTypes OBJECT IDENTIFIER ::= { bridgeRev1 4 } bdgTables OBJECT IDENTIFIER ::= { bridgeRev1 5 } acqDB OBJECT IDENTIFIER ::= { filterDB 1 } permDB OBJECT IDENTIFIER ::= { filterDB 2 } specialDB OBJECT IDENTIFIER ::= { filterDB 3 } acqStats OBJECT IDENTIFIER ::= { acqDB 1 } acqOptions OBJECT IDENTIFIER ::= { acqDB 2 } permStats OBJECT IDENTIFIER ::= { permDB 1 } permOptions OBJECT IDENTIFIER ::= { permDB 2 } specStats OBJECT IDENTIFIER ::= { specialDB 1 } specFilters OBJECT IDENTIFIER ::= { specialDB 2 } -- Device Object Definitions -- -- This section defines the objects under the Device node. -- -- Instance Identifiers for Device Objects -- -- There is only one instance of a Device object, thus the Instance -- Identifier is 0. -- -- Device Objects bdgdeviceDisableBdg OBJECT-TYPE SYNTAX INTEGER { disableBridge (0), enableBridge (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates if the bridge will be disabled." ::= { bdgdevice 1 } bdgdeviceRestoreSettings OBJECT-TYPE SYNTAX INTEGER { restoreSettings (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Restore the following settings to their default values: Bridge Name to ETHERNET_BRIDGE, Location to LOCAL, Port 1 Name to PORT_1, Port 2 Name to PORT_2, Port 1 Network Name to LAN_1, Port 2 Network Name to LAN_2, Ageing Time for Acquired Database to 300 seconds, Erase the acquired database, Erase the permanent database, Place sixteen default multicast addresses into the permanent and acquired databases, Type of Spanning Tree to 802.1, Type of Filtering to IEEE 802.1, Bridge Max Age to 20 seconds, Bridge Forward Delay to 15 seconds, Bridge Hello Time to 2 seconds, Bridge Priority to 8000, Port 1 Priority to 80, Port 2 Priority to 80, Port 1 Path Cost to 100, Port 2 Path Cost to 100, Restart the bridge." ::= { bdgdevice 2 } bdgdeviceBdgName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user-defined name (up to 32 characters long) of the bridge. The default bridge name is ETHERNET_BRIDGE." ::= { bdgdevice 4 } bdgdeviceNumPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of ports present on the bridge." ::= { bdgdevice 5 } bdgdeviceType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The type of bridge, NB25E, IRBM, or NB20E." ::= { bdgdevice 6 } bdgdeviceVersion OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The release version of the firmware installed in the bridge." ::= { bdgdevice 7 } bdgdeviceLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user-defined name to indicate the location of the bridge on the network. The default location name is LOCAL." ::= { bdgdevice 8 } bdgdeviceStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The status of the bridge, ON-LINE, STAND BY or DISABLED." ::= { bdgdevice 9 } bdgdeviceRestartBdg OBJECT-TYPE SYNTAX INTEGER { restartBridge (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Force the bridge to undergo a software reset." ::= { bdgdevice 10 } bdgdeviceFrFwd OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames forwarded by the bridge." ::= { bdgdevice 11 } bdgdeviceFrRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received by the bridge." ::= { bdgdevice 12 } bdgdeviceFrFlt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames filtered by the bridge." ::= { bdgdevice 13 } bdgdeviceErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of network errors that have occurred." ::= { bdgdevice 14 } bdgdeviceSwitchSetting OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the current switch settings read from the bridge hardware." ::= { bdgdevice 15 } bdgdeviceNumRestarts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the bridge has been powered up or restarted." ::= { bdgdevice 16 } bdgdeviceTypeFiltering OBJECT-TYPE SYNTAX INTEGER { ieee8021 (0), specialDB (1), both (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of filtering to be performed by the bridge. The default is IEEE 802.1." ::= { bdgdevice 17 } bdgdeviceSTAProtocol OBJECT-TYPE SYNTAX INTEGER { ieee8021 (0), dec (1), none (2) } ACCESS read-write STATUS mandatory DESCRIPTION "The spanning tree algorithm under which the bridge is operating. The selections are as follows: - IEEE 802.1 compliant spanning tree algorithm environment (802.1) - DEC LAN Bridge 100 environment (DEC) - Without the spanning tree algorithm enabled (NONE) The default is 802.1." ::= { bdgdevice 18 } bdgdeviceBridgeID OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier of the bridge. The first two bytes of the identifier are the bridge priority and the last six bytes are the Ethernet address." ::= { bdgdevice 19 } bdgdeviceTopChgCnt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times the bridge's Topology Change Flag has been changed since the bridge was powered up or initialized." ::= { bdgdevice 20 } bdgdeviceRootCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cost of the path to the root from this bridge." ::= { bdgdevice 21 } bdgdeviceRootPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port identifier for the port which offers the lowest cost path to the root, i.e. that port for which the sum of the values of the designated cost and path cost parameters held for the port is lowest." ::= { bdgdevice 22 } bdgdeviceHelloTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time interval between the transmission of Configuration BPDU's by a bridge which is attempting to become the root or is the root." ::= { bdgdevice 23 } bdgdeviceBdgMaxAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of the Max Age parameter when the bridge is the root or is attempting to become the root. A time of 6 to 40 seconds is allowed. The default is 20 seconds." ::= { bdgdevice 24 } bdgdeviceBdgFwdDly OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of the forward delay parameter when the bridge is the root or is attempting to become the root. A time of 4 to 30 seconds is allowed." ::= { bdgdevice 25 } bdgdeviceTimeTopChg OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time in seconds that has elapsed since the bridge's Topology Change Flag last recorded the value of a topology change." ::= { bdgdevice 26 } bdgdeviceTopChg OBJECT-TYPE SYNTAX INTEGER { noTopologyChangeInProgress (0), topologyChangeInProgress (1) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates if a bridge topology change is in progress." ::= { bdgdevice 27 } bdgdeviceDesigRoot OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The unique identifier of the bridge recorded as the root." ::= { bdgdevice 28 } bdgdeviceMaxAge OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum age of received protocol information before it is discarded." ::= { bdgdevice 29 } bdgdeviceHoldTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum time period elapsing between the transmission of configuration BPDU's through a given bridge port." ::= { bdgdevice 30 } bdgdeviceFwdDly OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time spent in the listening state while moving from the blocking state to the learning state, or the time spent in the learning state while moving from the listening state to the forwarding state." ::= { bdgdevice 31 } bdgdeviceBdgHello OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The value of the Hello Time parameter when the bridge is the root or is attempting to become the root. A time of 1 to 10 seconds is allowed. The default is 2 seconds." ::= { bdgdevice 32 } bdgdeviceBdgPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The part of the bridge address that contains the identifier used in the spanning tree for priority comparisons. Allowed range is 0 through FFFF. The default is 8000." ::= { bdgdevice 33 } bdgdeviceResetCounts OBJECT-TYPE SYNTAX INTEGER { resetCounts (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Reset all counters to zero." ::= { bdgdevice 34 } bdgdeviceUptime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The time, in seconds, that has elapsed since the bridge was last reset or initialized." ::= { bdgdevice 35 } bdgdeviceTrapType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "Contains the object identifier of the first VarBinding in the last trap generated by the bridge." ::= { bdgdevice 36 } -- Port Object Definitions -- -- This section defines the objects under the Port node. -- -- Instance Identifiers for Port Objects -- -- The Instance Identifier for port objects is the number of the port on -- the bridge. Valid instance identifiers for the ports on the IRBM, -- NB25E, and NB20E bridges are 1 and 2. -- -- Port Objects bdgPortAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The Ethernet address of the port." ::= { bdgPort 1 } bdgPortName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user-defined name assigned to the port. The default port 1 name is PORT_1 and the default Port 2 name is PORT_2." ::= { bdgPort 2 } bdgPortType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The IEEE specification the port meets, e.g. 802.3." ::= { bdgPort 3 } bdgPortStatus OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The status in which the port is operating. The status messages for Ports 1 and 2 are: OFF - The port is off, due to a failed network interface chip associated with that port. OK/SQE ON - The port is communicating with the network and the transceiver making the connection to the network has SQE enabled. OK/SQE OFF - The port is communicating with the network and the transceiver making the connection to the network has SQE disabled. CARRIER LOST - Communication with the network has not been established or has been lost." ::= { bdgPort 4 } bdgPortNetName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "The user-defined name assigned to a network segment connected to the port. The default network name for Port 1 is LAN_1 and the default network name for Port 2 is LAN_2." ::= { bdgPort 5 } bdgPortFrRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received at the specified port." ::= { bdgPort 6 } bdgPortDisInb OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of valid frames that were received at the port but then discarded by the bridge in the forwarding process." ::= { bdgPort 7 } bdgPortFwdOutb OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames forwarded successfully to the appropriate port." ::= { bdgPort 8 } bdgPortDisLOB OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets that were discarded by the bridge because of a lack of buffer space to maintain the data." ::= { bdgPort 9 } bdgPortDisTDE OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that were intended for forwarding but were discarded when the maximum time period set for transmission was exceeded before forwarding was possible." ::= { bdgPort 10 } bdgPortDisErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames that could not be transmitted because the frame was too large for the attached network (1526 bytes, including preamble, for 802.3 networks)." ::= { bdgPort 11 } bdgPortColl OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of collisions that have occurred on the network at the specified port." ::= { bdgPort 12 } bdgPortTxAbrt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmissions that have been aborted due to excessive collisions (over 16 attempts to transmit the same packet)." ::= { bdgPort 13 } bdgPortOowColl OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of collisions out of the standard collision window (51.2 uS). This indicates a network problem." ::= { bdgPort 14 } bdgPortCRCErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets detected with Cyclical Redundancy Check failures." ::= { bdgPort 15 } bdgPortFrAlErr OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of errors due to misaligned packets." ::= { bdgPort 16 } bdgPortPriority OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The part of the port identifier which is used with the spanning tree algorithm when determining which port in a LAN segment has priority. The default is 80." ::= { bdgPort 17 } bdgPortState OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The current state of the port, DISABLED, LISTENING, LEARNING, FORWARDING or BLOCKING." ::= { bdgPort 18 } bdgPortPathCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The contributory cost of the applicable port to the overall cost of the path when the specified port is the root port. Allowable range is 1 to 65535. The default is 100." ::= { bdgPort 19 } bdgPortDesigCost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The cost of the path of this port to the root bridge on the network." ::= { bdgPort 20 } bdgPortDesigBrdg OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The network address of the bridge that is assumed to be the root bridge on the network." ::= { bdgPort 21 } bdgPortDesigPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The port identifier of the bridge port believed to be the designated port for the LAN associated with the port." ::= { bdgPort 22 } bdgPortTopChgAck OBJECT-TYPE SYNTAX INTEGER { noTopologyChangeIsOccurring (0), topologyChangeIsOccurring (1) } ACCESS read-only STATUS mandatory DESCRIPTION "The value of the topology change acknowledgement flag in the next configuration BPDU to be transmitted on the associated port." ::= { bdgPort 23 } bdgPortDesigRoot OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The unique bridge identifier of the bridge that is assumed to be the root bridge on the network." ::= { bdgPort 24 } bdgPortRuntPackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received at the indicated bdgPort that were less than the IEEE 802.3 minimum Ethernet frame size of 64 bytes." ::= { bdgPort 25 } bdgPortOversizePackets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received at the indicated port that were greater than the IEEE 802.3 maximum Ethernet frame size of 1518 bytes." ::= { bdgPort 26 } bdgPortFrFilt OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received at the indicated port that were filtered by the bridge." ::= { bdgPort 27 } -- Acquired Database Statistical Object Definitions -- -- This section defines the objects under the Acquired Database -- Statistics node. -- -- Instance Identifiers for Acquired Database Statistical Objects -- -- There is only one instance of an Acquired Database Statistical object, -- thus the Instance Identifier is 0. -- -- Acquired Database Statistical Objects acqTotalEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of entries in the acquired database." ::= { acqStats 1 } acqMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of entries allowed in the acquired database." ::= { acqStats 2 } acqStaticEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of addresses added to the Acquired database by the user or network manager." ::= { acqStats 3 } acqStaticAgeTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The length of time allowed for a static entry in the Acquired database to be inactive before it is dropped from the database. This time is fixed at zero." ::= { acqStats 4 } acqDynEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of entries that have been accumulated in the Acquired database through the bridge's learning process." ::= { acqStats 5 } acqDynAgeTime OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The length of time allowed for a dynamic entry in the acquired database to be inactive before it is dropped from the database. A time from 10 - 1,000,000 seconds is allowed. The default is 300 seconds." ::= { acqStats 6 } acqEraseDatabase OBJECT-TYPE SYNTAX INTEGER { eraseAcquiredDatabase (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Set to zero to erase all entries in the acquired database." ::= { acqStats 7 } -- Acquired Database Option Object Definitions -- -- This section defines the objects under the Acquired Database -- Option node. -- -- Instance Identifiers for Acquired Database Option Objects -- -- The instance identifier for the acquired database option objects is -- the 6-byte Ethernet address of the device to be added, deleted or -- displayed to/from the acquired database. -- -- Acquired Database Option Objects acqCreate00 OBJECT-TYPE SYNTAX INTEGER { createAcquiredEntryFilterPort1FilterPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the acquired database to filter packets entering ports 1 and 2 if those packets are destined for the specified address." ::= { acqOptions 1 } acqCreate20 OBJECT-TYPE SYNTAX INTEGER { createAcquiredEntryForwardPort1FilterPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the acquired database to forward packets entering port1 to port2 and filter packets entering port2 if those packets are destined for the specified address." ::= { acqOptions 2 } acqCreate01 OBJECT-TYPE SYNTAX INTEGER { createAcquiredEntryFilterPort1ForwardPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the acquired database to filter packets entering port 1 and forward packets entering port 2 to port 1 if those packets are destined for the specified address." ::= { acqOptions 3 } acqCreate21 OBJECT-TYPE SYNTAX INTEGER { createAcquiredEntryForwardPort1ForwardPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the acquired database to forward packets entering port 1 to port 2 and to forward packets entering port 2 to port 1 if those packets are destined for the specified address." ::= { acqOptions 4 } acqDelete OBJECT-TYPE SYNTAX INTEGER { deleteAcquiredEntry (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete an entry from the acquired database." ::= { acqOptions 5 } acqDispType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Display the entry type, STATIC or DYNAMIC." ::= { acqOptions 6 } acqDispOutp1 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The outbound port for packets entering port 1." ::= { acqOptions 7 } acqDispOutp2 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (1) } ACCESS read-only STATUS mandatory DESCRIPTION "The outbound port for packets entering port 2." ::= { acqOptions 8 } acqSrcAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The source address of this acquired database entry, i.e. the instance." ::= { acqOptions 9 } -- Permanent Database Statistical Object Definitions -- -- This section defines the objects under the Permanent Database -- Statistics node. -- -- Instance Identifiers for Permanent Database Statistical Objects -- -- There is only one instance of an Permanent Database Statistical -- object, thus the Instance Identifier is 0. -- -- Permanent Database Statistical Objects permMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of entries allowed in the permanent database." ::= { permStats 1 } permCurrEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of entries currently recorded in the bridge's permanent database." ::= { permStats 2 } permEraseDatabase OBJECT-TYPE SYNTAX INTEGER { erasePermanentDatabase (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Erase all entries in the permanent database." ::= { permStats 3 } -- Permanent Database Option Object Definitions -- -- This section defines the objects under the Permanent Database -- Option node. -- -- Instance Identifiers for Permanent Database Option Objects -- -- The instance identifier for the permanent database option objects is -- the 6-byte Ethernet address of the device to be added, deleted or -- displayed to/from the permanent database. -- -- Permanent Database Option Objects permCreate00 OBJECT-TYPE SYNTAX INTEGER { createPermanentEntryFilterPort1FilterPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the permanent database to filter packets entering ports 1 and 2 if those packets are destined for the specified address." ::= { permOptions 1 } permCreate20 OBJECT-TYPE SYNTAX INTEGER { createPermanentEntryForwardPort1FilterPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the permanent database to forward packets entering port 1 and filter packets entering port 2 if those packets are destined for the specified address." ::= { permOptions 2 } permCreate01 OBJECT-TYPE SYNTAX INTEGER { createPermanentEntryFilterPort1ForwardPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the permanent database to filter packets entering port 1 and forward packets entering port 2 if those packets are destined for the specified address." ::= { permOptions 3 } permCreate21 OBJECT-TYPE SYNTAX INTEGER { createPermanentEntryForwardPort1ForwardPort2 (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Add an entry to the permanent database to forward packets entering ports 1 and 2 if those packets are destined for the specified address." ::= { permOptions 4 } permDelete OBJECT-TYPE SYNTAX INTEGER { deletePermanentEntry (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete an entry from the permanent database." ::= { permOptions 5 } permDispType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Display the entry type, STATIC or DYNAMIC." ::= { permOptions 6 } permDispOutp1 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (2) } ACCESS read-only STATUS mandatory DESCRIPTION "The outbound port for packets entering port 1." ::= { permOptions 7 } permDispOutp2 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (1) } ACCESS read-only STATUS mandatory DESCRIPTION "The outbound port for packets entering port 2." ::= { permOptions 8 } permSrcAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The source address in this permanent database entry, i.e. the instance." ::= { permOptions 9 } -- Special Database Statistical Object Definitions -- -- This section defines the objects under the Special Database -- Statistical node. -- -- Instance Identifiers for Special Database Statistical Objects -- -- There is only one instance of a Special Database Statistical object, -- thus the Instance Identifier is 0. -- -- Special Database Statistical Objects specNumEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of filters in the special database." ::= { specStats 1 } specMaxEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of filters the special database can contain." ::= { specStats 2 } specNextFilterNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of the next available filter that can be added to the special database." ::= { specStats 3 } -- Special Database Filter Object Definitions -- -- This section defines the objects under the Special Database -- Filter node. -- -- Instance Identifiers for Special Database Filter Objects -- -- The instance identifier of the special database filter objects -- is the filter number, values from 1 through 10 are allowed. -- -- Special Database Filter Objects specEnable OBJECT-TYPE SYNTAX INTEGER { disableFilter (0), enableFilter (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable or disable the filter." ::= { specFilters 1 } specPort1 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Set port 1 to filter or forward packets." ::= { specFilters 2 } specPort2 OBJECT-TYPE SYNTAX INTEGER { filter (0), relay (1) } ACCESS read-write STATUS mandatory DESCRIPTION "Set port 2 to filter or forward packets." ::= { specFilters 3 } specDestAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the special database to filter packets with a specific destination address." ::= { specFilters 4 } specSrcAddress OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the special database to filter packets with a specific source address." ::= { specFilters 5 } specType OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the special database to filter packets with a specific type field." ::= { specFilters 6 } specDataField OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Set the special database to filter packets based on the first sixteen bytes of data in the packet." ::= { specFilters 7 } specDeleteFilter OBJECT-TYPE SYNTAX INTEGER { deleteFilter (0) } ACCESS read-write STATUS mandatory DESCRIPTION "Delete a filter from the special database." ::= { specFilters 8 } -- TRAP TYPES OBJECT DEFINITIONS -- -- This section describes the trap types that the bridge can generate. These -- are not objects, but Object Identifiers used to indicate the specific trap. -- They are taken from the object space and are thus documented here. -- -- The SNMP trap messages are composed of two user definable areas: -- a) the specific trap type and -- b) the VarBindings (e.g. the interesting information) -- -- The specific trap type is an integer that is used to determine the -- specific trap which has occurred. The "interesting information" contains -- a group of object identifiers and their values that provide information -- about the trap. -- -- Trap Decription -- -- BridgeStatus -- -- Specific Trap Type Code - 0x0301 -- -- When the bridge status changes, a trap will be generated. The -- interesting information includes the current status of the bridge. -- -- -- Trap Description -- -- AcqDbaseFull -- -- Specific Trap Type Code - 0x0302 -- -- When the acquired portion of the bridge's filtering database is full, a -- trap is generated. The interesting information included with this trap -- is the number of entries in the acquired database. -- Formal definition of the Layer Management MIB. (e.g. PC cards ) lmcommon OBJECT IDENTIFIER ::= { layerMgmt 1 } mAC OBJECT IDENTIFIER ::= { layerMgmt 2 } ieee8023 OBJECT IDENTIFIER ::= { mAC 1 } pcIF OBJECT IDENTIFIER ::= { ieee8023 1 } pcIfRev OBJECT IDENTIFIER ::= { pcIF 1 } pcDeviceName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Name of the PC device" ::= { pcIfRev 1 } pcBoardType OBJECT-TYPE SYNTAX OBJECT IDENTIFIER ACCESS read-only STATUS mandatory DESCRIPTION "An object Identifier that indicates the type of the PC board. This will include MAC type and Media type." ::= { pcIfRev 2 } pcOwnerName OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The owner of this PC." ::= { pcIfRev 3 } pcLocation OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the location of this PC." ::= { pcIfRev 4 } pcMMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the MMAC that this PC is connected to." ::= { pcIfRev 5 } pcMMACBoard OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The slot number of the board in the MMAC that this PC is connected to." ::= { pcIfRev 6 } pcMMACPort OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The number of the port on the board of the MMAC that this PC is connected to." ::= { pcIfRev 7 } pcApplication OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A text description of the network application running on this PC." ::= { pcIfRev 8 } pcDriverRev OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The revision of the LAN card driver." ::= { pcIfRev 9 } pcOnboardMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of Kilobytes of memory (eg. a 16K board would reply 16)" ::= { pcIfRev 10 } pcComment OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A user-defined character string." ::= { pcIfRev 11 } pcMACAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "The MAC address of the PC card." ::= { pcIfRev 12 } pcFramesXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of MAC frames transmitted by this PC card." ::= { pcIfRev 13 } pcBytesXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number bytes transmitted by this PC card." ::= { pcIfRev 14 } pcMcastXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of multicasted frames sent by this PC card." ::= { pcIfRev 15 } pcBcastXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of broadcast frames from this PC card." ::= { pcIfRev 16 } pcDeferXmit OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packets that were deferred due to busy media." ::= { pcIfRev 17 } pcSglColl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packet experiencing a single collision." ::= { pcIfRev 18 } pcMultiColl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packets that have experienced multiple collisions." ::= { pcIfRev 19 } pcTotXmitErrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of transmit errors." ::= { pcIfRev 20 } pcLateColls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packets that experienced late collisions." ::= { pcIfRev 21 } pcXcessColls OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packets aborted due to excess collisions." ::= { pcIfRev 22 } pcCarrErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of transmit packets that experience carrier sense errors (ie. lose carrier during transmission)." ::= { pcIfRev 23 } pcFramesRec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of frames received." ::= { pcIfRev 24 } pcBytesRec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of bytes received by this station." ::= { pcIfRev 25 } pcMcastRec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of multicasted frames received." ::= { pcIfRev 26 } pcBcastRec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of broadcast packets received." ::= { pcIfRev 27 } pcTotRecErrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of receive errors." ::= { pcIfRev 28 } pcTooLong OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets received that are too long (over 1518 bytes)." ::= { pcIfRev 29 } pcTooShort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets that are too short. (under 64 bytes long)." ::= { pcIfRev 30 } pcAlignErrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of alignment errors in receive packets." ::= { pcIfRev 31 } pcCRCErrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive packets with CRC errors." ::= { pcIfRev 32 } pcLenErrs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of packets whose length is not equal to the number of bytes received." ::= { pcIfRev 33 } pcIntRecErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of receive packets that experienced internal errors (eg. no receive buffers)." ::= { pcIfRev 34 } pcSqeErr OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of SQE errors." ::= { pcIfRev 35 } END