You are here:

MonitorTools.com > Technical documentation > SNMP > MIB > Wellfleet > Wellfleet-DS3-MIB
ActiveXperts Network Monitor 2019##AdminFavorites

Wellfleet-DS3-MIB by vendor Wellfleet

Wellfleet-DS3-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing Wellfleet-DS3-MIB.


Vendor: Wellfleet
Mib: Wellfleet-DS3-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
Wellfleet-DS3-MIB DEFINITIONS ::= BEGIN

-- Created by mdl2asn version 3.1
-- Creation date: Wed Aug 30 16:40:18 EDT 1995


    IMPORTS

      IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt
        FROM RFC1155-SMI
      OBJECT-TYPE
        FROM RFC-1212
      TRAP-TYPE
        FROM RFC-1215
      DisplayString, mib-2
        FROM RFC1213-MIB
      wfDs3Group
        FROM Wellfleet-COMMON-MIB;


    wfDs3Config OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3ConfigEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Configuration table"
        ::= { wfDs3Group 1 }

    wfDs3ConfigEntry OBJECT-TYPE
        SYNTAX	WfDs3ConfigEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 configuration objects; wfDs3LineIndex
                corresponds to Wellfleet circuit number"
        INDEX	{ wfDs3LineIndex }
        ::= { wfDs3Config 1 }

    WfDs3ConfigEntry ::= SEQUENCE {
    	    wfDs3LineIndex
    		INTEGER,
    	    wfDs3TimeElapsed
    		INTEGER,
    	    wfDs3ValidIntervals
    		INTEGER,
    	    wfDs3LineType
    		INTEGER,
    	    wfDs3ZeroCoding
    		INTEGER,
    	    wfDs3SendCode
    		INTEGER,
    	    wfDs3CircuitIdentifier
    		DisplayString,
    	    wfDs3LoopbackConfig
    		INTEGER,
    	    wfDs3LineStatus
    		INTEGER
        }

    wfDs3LineIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3ConfigEntry 1 }

    wfDs3TimeElapsed OBJECT-TYPE
        SYNTAX	INTEGER
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "1..900 seconds within the current 15-minute interval"
        ::= { wfDs3ConfigEntry 2 }

    wfDs3ValidIntervals OBJECT-TYPE
        SYNTAX	INTEGER
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "0..96 previous intervals that valid data
                were collected. This is 96 unless the CSU
                device was brought on line within the last 24
                hours."
        ::= { wfDs3ConfigEntry 3 }

    wfDs3LineType OBJECT-TYPE
        SYNTAX	INTEGER {
    		    other(1),
    		    ds3cbitparity(4),
    		    ds3clearchannel(5)
    		}
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the variety of DS3 implementing this circuit"
        ::= { wfDs3ConfigEntry 4 }

    wfDs3ZeroCoding OBJECT-TYPE
        SYNTAX	INTEGER {
    		    ds3b3zs(2)
    		}
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the variety of Zero Code Suppression used on the link"
        ::= { wfDs3ConfigEntry 5 }

    wfDs3SendCode OBJECT-TYPE
        SYNTAX	INTEGER {
    		    ds3sendnocode(2)
    		}
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the type of code being sent across the DS3 circuit by
                the CSU"
        ::= { wfDs3ConfigEntry 6 }

    wfDs3CircuitIdentifier OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the transmission vendor's circuit identifier"
        ::= { wfDs3ConfigEntry 7 }

    wfDs3LoopbackConfig OBJECT-TYPE
        SYNTAX	INTEGER {
    		    ds3noloop(1),
    		    ds3mgrpayloadloop(2),
    		    ds3mgrlineloop(3),
    		    ds3netreqpayloadloop(4),
    		    ds3netreqlineloop(5),
    		    ds3otherloop(6)
    		}
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the loopback state of the CSU"
        ::= { wfDs3ConfigEntry 8 }

    wfDs3LineStatus OBJECT-TYPE
        SYNTAX	INTEGER {
    		    ds3noalarm(1),
    		    ds3farendalarm(2),
    		    ds3alarmindicationsignal(4),
    		    ds3lossofframe(8),
    		    ds3lossofsignal(16),
    		    ds3loopbackstate(32)
    		}
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the state of the DS3 line"
        ::= { wfDs3ConfigEntry 9 }

    wfDs3Current OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3CurrentEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Current table"
        ::= { wfDs3Group 2 }

    wfDs3CurrentEntry OBJECT-TYPE
        SYNTAX	WfDs3CurrentEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 current objects - wfDs3CurrentIndex
                corresponds to Wellfleet circuit number"
        INDEX	{ wfDs3CurrentIndex }
        ::= { wfDs3Current 1 }

    WfDs3CurrentEntry ::= SEQUENCE {
    	    wfDs3CurrentIndex
    		INTEGER,
    	    wfDs3CurrentESs
    		Counter,
    	    wfDs3CurrentSESs
    		Counter,
    	    wfDs3CurrentSEFs
    		Counter,
    	    wfDs3CurrentUASs
    		Counter,
    	    wfDs3CurrentBPVs
    		Counter,
    	    wfDs3CurrentCVs
    		Counter
        }

    wfDs3CurrentIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3CurrentEntry 1 }

    wfDs3CurrentESs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of errored seconds in the current interval"
        ::= { wfDs3CurrentEntry 2 }

    wfDs3CurrentSESs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored seconds in the
                current interval"
        ::= { wfDs3CurrentEntry 3 }

    wfDs3CurrentSEFs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored framing seconds in the current
                interval"
        ::= { wfDs3CurrentEntry 4 }

    wfDs3CurrentUASs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the number of unavailable seconds in the current interval"
        ::= { wfDs3CurrentEntry 5 }

    wfDs3CurrentBPVs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of bipolar violations in the current interval"
        ::= { wfDs3CurrentEntry 6 }

    wfDs3CurrentCVs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of code violation error events in the
                current interval"
        ::= { wfDs3CurrentEntry 7 }

    wfDs3Interval OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3IntervalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Interval table"
        ::= { wfDs3Group 3 }

    wfDs3IntervalEntry OBJECT-TYPE
        SYNTAX	WfDs3IntervalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 interval objects - wfDs3IntervalIndex
                corresponds to Wellfleet circuit number,
                wfDs3IntervalNumber is the numbered previous
                15-minute interval"
        INDEX	{ wfDs3IntervalIndex,
    		  wfDs3IntervalNumber }
        ::= { wfDs3Interval 1 }

    WfDs3IntervalEntry ::= SEQUENCE {
    	    wfDs3IntervalIndex
    		INTEGER,
    	    wfDs3IntervalNumber
    		INTEGER,
    	    wfDs3IntervalESs
    		Gauge,
    	    wfDs3IntervalSESs
    		Gauge,
    	    wfDs3IntervalSEFs
    		Gauge,
    	    wfDs3IntervalUASs
    		Gauge,
    	    wfDs3IntervalBPVs
    		Gauge,
    	    wfDs3IntervalCVs
    		Gauge
        }

    wfDs3IntervalIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3IntervalEntry 1 }

    wfDs3IntervalNumber OBJECT-TYPE
        SYNTAX	INTEGER(1..96)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "1..96 where 1 is the most recent 15-minute interval and 96 is
                the least"
        ::= { wfDs3IntervalEntry 2 }

    wfDs3IntervalESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of errored seconds in the specified interval"
        ::= { wfDs3IntervalEntry 3 }

    wfDs3IntervalSESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored seconds in the specified
                interval"
        ::= { wfDs3IntervalEntry 4 }

    wfDs3IntervalSEFs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored framing seconds in the specified
                interval"
        ::= { wfDs3IntervalEntry 5 }

    wfDs3IntervalUASs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the number of unavailable seconds in the specified interval"
        ::= { wfDs3IntervalEntry 6 }

    wfDs3IntervalBPVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of bipolar violations in the specified interval"
        ::= { wfDs3IntervalEntry 7 }

    wfDs3IntervalCVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of code violation error events in the
                specified interval"
        ::= { wfDs3IntervalEntry 8 }

    wfDs3Total OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3TotalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Total table"
        ::= { wfDs3Group 4 }

    wfDs3TotalEntry OBJECT-TYPE
        SYNTAX	WfDs3TotalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 total objects - wfDs3TotalIndex
                corresponds to Wellfleet circuit number"
        INDEX	{ wfDs3TotalIndex }
        ::= { wfDs3Total 1 }

    WfDs3TotalEntry ::= SEQUENCE {
    	    wfDs3TotalIndex
    		INTEGER,
    	    wfDs3TotalESs
    		Gauge,
    	    wfDs3TotalSESs
    		Gauge,
    	    wfDs3TotalSEFs
    		Gauge,
    	    wfDs3TotalUASs
    		Gauge,
    	    wfDs3TotalBPVs
    		Gauge,
    	    wfDs3TotalCVs
    		Gauge
        }

    wfDs3TotalIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3TotalEntry 1 }

    wfDs3TotalESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of errored seconds"
        ::= { wfDs3TotalEntry 2 }

    wfDs3TotalSESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of severely errored seconds"
        ::= { wfDs3TotalEntry 3 }

    wfDs3TotalSEFs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of severely errored framing seconds"
        ::= { wfDs3TotalEntry 4 }

    wfDs3TotalUASs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total number of unavailable seconds"
        ::= { wfDs3TotalEntry 5 }

    wfDs3TotalBPVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of bipolar violations"
        ::= { wfDs3TotalEntry 6 }

    wfDs3TotalCVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of code violation error events"
        ::= { wfDs3TotalEntry 7 }

    wfDs3FeConfig OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3FeConfigEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Far End Configuration table"
        ::= { wfDs3Group 5 }

    wfDs3FeConfigEntry OBJECT-TYPE
        SYNTAX	WfDs3FeConfigEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 far end config objects -
                wfDs3FeIntervalIndex corresponds to Wellfleet circuit
                number"
        INDEX	{ wfDs3FeConfigIndex }
        ::= { wfDs3FeConfig 1 }

    WfDs3FeConfigEntry ::= SEQUENCE {
    	    wfDs3FeConfigIndex
    		INTEGER,
    	    wfDs3FarEndEquipCode
    		DisplayString,
    	    wfDs3FarEndLocationIDCode
    		DisplayString,
    	    wfDs3FarEndFrameIDCode
    		DisplayString,
    	    wfDs3FarEndUnitCode
    		DisplayString,
    	    wfDs3FarEndFacilityIDCode
    		DisplayString
        }

    wfDs3FeConfigIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3FeConfigEntry 1 }

    wfDs3FarEndEquipCode OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "equipment description code - C-bit parity only"
        ::= { wfDs3FeConfigEntry 2 }

    wfDs3FarEndLocationIDCode OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "equipment location code - C-bit parity only"
        ::= { wfDs3FeConfigEntry 3 }

    wfDs3FarEndFrameIDCode OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "code for the equipment location within a building"
        ::= { wfDs3FeConfigEntry 4 }

    wfDs3FarEndUnitCode OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "code for the equipment location within a bay"
        ::= { wfDs3FeConfigEntry 5 }

    wfDs3FarEndFacilityIDCode OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "path identification code"
        ::= { wfDs3FeConfigEntry 6 }

    wfDs3FeCurrent OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3FeCurrentEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Far End Current table"
        ::= { wfDs3Group 6 }

    wfDs3FeCurrentEntry OBJECT-TYPE
        SYNTAX	WfDs3FeCurrentEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 far end current objects
                wfDs3FeCurrentIndex corresponds to Wellfleet circuit
                number"
        INDEX	{ wfDs3FeCurrentIndex }
        ::= { wfDs3FeCurrent 1 }

    WfDs3FeCurrentEntry ::= SEQUENCE {
    	    wfDs3FeCurrentIndex
    		INTEGER,
    	    wfDs3FeCurrentESs
    		Counter,
    	    wfDs3FeCurrentSESs
    		Counter,
    	    wfDs3FeCurrentCVs
    		Counter
        }

    wfDs3FeCurrentIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3FeCurrentEntry 1 }

    wfDs3FeCurrentESs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of errored seconds in the current interval"
        ::= { wfDs3FeCurrentEntry 2 }

    wfDs3FeCurrentSESs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored seconds in the
                current interval"
        ::= { wfDs3FeCurrentEntry 3 }

    wfDs3FeCurrentCVs OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of code violation error events in the
                current interval"
        ::= { wfDs3FeCurrentEntry 4 }

    wfDs3FeInterval OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3FeIntervalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Far End Interval table"
        ::= { wfDs3Group 7 }

    wfDs3FeIntervalEntry OBJECT-TYPE
        SYNTAX	WfDs3FeIntervalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit DS3 far end interval objects -
                wfDs3FeIntervalIndex corresponds to Wellfleet circuit
                number, wfDs3FeIntervalNumber is the numbered previous
                15-minute interval"
        INDEX	{ wfDs3FeIntervalIndex,
    		  wfDs3FeIntervalNumber }
        ::= { wfDs3FeInterval 1 }

    WfDs3FeIntervalEntry ::= SEQUENCE {
    	    wfDs3FeIntervalIndex
    		INTEGER,
    	    wfDs3FeIntervalNumber
    		INTEGER,
    	    wfDs3FeIntervalESs
    		Gauge,
    	    wfDs3FeIntervalSESs
    		Gauge,
    	    wfDs3FeIntervalCVs
    		Gauge
        }

    wfDs3FeIntervalIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3FeIntervalEntry 1 }

    wfDs3FeIntervalNumber OBJECT-TYPE
        SYNTAX	INTEGER(1..96)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "1..96 where 1 is the most recent 15-minute interval and 96 is
                the least"
        ::= { wfDs3FeIntervalEntry 2 }

    wfDs3FeIntervalESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of errored seconds in the specified interval"
        ::= { wfDs3FeIntervalEntry 3 }

    wfDs3FeIntervalSESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of severely errored seconds in the
                specified interval"
        ::= { wfDs3FeIntervalEntry 4 }

    wfDs3FeIntervalCVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "the count of code violation error events in the
                specified interval"
        ::= { wfDs3FeIntervalEntry 5 }

    wfDs3FeTotal OBJECT-TYPE
        SYNTAX	SEQUENCE OF WfDs3FeTotalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "The DS3 Far End Total table"
        ::= { wfDs3Group 8 }

    wfDs3FeTotalEntry OBJECT-TYPE
        SYNTAX	WfDs3FeTotalEntry
        ACCESS	not-accessible
        STATUS	mandatory
        DESCRIPTION
                "per circuit far end DS3 total objects - wfDs3FeTotalIndex
                corresponds to Wellfleet circuit number"
        INDEX	{ wfDs3FeTotalIndex }
        ::= { wfDs3FeTotal 1 }

    WfDs3FeTotalEntry ::= SEQUENCE {
    	    wfDs3FeTotalIndex
    		INTEGER,
    	    wfDs3FeTotalESs
    		Gauge,
    	    wfDs3FeTotalSESs
    		Gauge,
    	    wfDs3FeTotalCVs
    		Gauge
        }

    wfDs3FeTotalIndex OBJECT-TYPE
        SYNTAX	INTEGER(1..1024)
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "this corresponds to the Wellfleet circuit number"
        ::= { wfDs3FeTotalEntry 1 }

    wfDs3FeTotalESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of errored seconds"
        ::= { wfDs3FeTotalEntry 2 }

    wfDs3FeTotalSESs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of severely errored seconds"
        ::= { wfDs3FeTotalEntry 3 }

    wfDs3FeTotalCVs OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "total count of code violation error events"
        ::= { wfDs3FeTotalEntry 4 }

    END  -- Wellfleet-DS3-MIB