ANNEX-MIB -- -- Xylogics Annex Private Enterprise MIB -- -- Copyright 1991, Xylogics, Inc. ALL RIGHTS RESERVED. -- -- ALL RIGHTS RESERVED. Licensed Material - Property of Xylogics, Inc. -- This software is made available solely pursuant to the terms of a -- software license agreement which governs its use. -- Unauthorized duplication, distribution or sale are strictly prohibited. -- -- This information is subject to change without notice, and should -- not be construed as a commitment by Xylogics, Inc. Xylogics, Inc., -- assumes no responsibility for any errors that may appear in this -- document. -- -- $Id: ccaseimp10296.10489,v /main/2 1994/06/27 05:35 UTC build Exp $ -- -- overview ANNEX-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks FROM RFC1155-SMI DisplayString, PhysAddress FROM RFC1213-MIB OBJECT-TYPE FROM RFC-1212; xylogics OBJECT IDENTIFIER ::= { enterprises 15 } prod OBJECT IDENTIFIER ::= { xylogics 1 } prodannex OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "Product name." ::= { prod 1 } annex OBJECT IDENTIFIER ::= { xylogics 2 } hw OBJECT IDENTIFIER ::= { annex 1 } sw OBJECT IDENTIFIER ::= { annex 2 } ports OBJECT IDENTIFIER ::= { annex 3 } parallelport OBJECT IDENTIFIER ::= { annex 4 } annexconfig OBJECT IDENTIFIER ::= { annex 5 } annexcmds OBJECT IDENTIFIER ::= { annex 6 } -- the hw group hwType OBJECT-TYPE SYNTAX INTEGER { err(1), annexII(16), annex3(42), microannex(52), microels(55) } ACCESS read-only STATUS mandatory DESCRIPTION "An identifier for the Annex hardware type." ::= { hw 1 } hwRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The revision level of the hardware platform." ::= { hw 2 } romRev OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The revision number of the ROM Monitor software." ::= { hw 3 } serialNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The serial number assigned to the unit." ::= { hw 4 } memorySize OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of memory present in the unit." ::= { hw 5 } -- the sw group swType OBJECT-TYPE SYNTAX INTEGER { err(1), annexIImx(16), annexIIux(17), annex3ux(42), annex3mx(43), microannexux(52), microannexmx(53), microels(55) } ACCESS read-only STATUS mandatory DESCRIPTION "The software version currently running on the Annex." ::= { sw 1 } swRevMajor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The major software release number." ::= { sw 2 } swRevMinor OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minor software release number." ::= { sw 3 } swBuild OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The full name of the software build, including the software version, major and minor version numbers and the date and time of the build." ::= { sw 4 } imageName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-only STATUS mandatory DESCRIPTION "The name of the most recently booted image." ::= { sw 5 } bootHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "The Internet address of the host from which the Annex booted." ::= { sw 6 } defaultDomain OBJECT-TYPE SYNTAX DisplayString (SIZE (0..128)) ACCESS read-only STATUS mandatory DESCRIPTION "The default domain name provided by the DNS nameserver." ::= { sw 7 } currentDate OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-only STATUS mandatory DESCRIPTION "The current date and time provided by the time server." ::= { sw 8 } usableMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The amount of available for data buffers and other structures after the Annex has booted." ::= { sw 9 } freeMemory OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The amount of currently available memory." ::= { sw 10 } minFreeMemory OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum amount of free memory since booting the Annex." ::= { sw 11 } cpuUtilization OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Percent of CPU time currently being used." ::= { sw 12 } maxProcs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The total number of process structures allocated for use." ::= { sw 13 } mostProcs OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The maximum number of active processes since the Annex was booted." ::= { sw 14 } activeProcs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of currently active processes." ::= { sw 15 } cpuIRescheds OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of processes whose time slice has expired in the last minute." ::= { sw 16 } cpuTRescheds OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of processes whose time slice has expired since booting the Annex." ::= { sw 17 } contextISwtchs OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of context switches in the last minute." ::= { sw 18 } contextTSwtchs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of context switches since booting the Annex." ::= { sw 19 } cpuIActivates OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The number of processes that were activated in the last minute." ::= { sw 20 } cpuTActivates OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of processes that were activated since booting the Annex." ::= { sw 21 } maxCallouts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of allocated Callout structures for timed events in the Annex." ::= { sw 22 } leastCallouts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The minimum number of Callout structures available since last booting the Annex." ::= { sw 23 } freeCallouts OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The current number of free Callout structures." ::= { sw 24 } -- the ports group totalPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of serial ports on this Annex." ::= { ports 1 } totalInChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of characters received on all serial ports." ::= { ports 2 } totalOutChars OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of characters transmitted on all serial ports." ::= { ports 3 } totalParityErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of parity errors detected on all serial ports." ::= { ports 4 } totalOverrunErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of overruns detected on all serial ports." ::= { ports 5 } totalFramingErrs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of framing errors detected on all serial ports." ::= { ports 6 } portTable OBJECT-TYPE SYNTAX SEQUENCE OF PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of port entries." ::= { ports 7 } portEntry OBJECT-TYPE SYNTAX PortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The port's configuration parameters." INDEX { anxpPortIndex } ::= { portTable 1 } PortEntry ::= SEQUENCE { anxpPortIndex INTEGER, anxpMode INTEGER, anxpCtrlLines INTEGER, anxpBidirModem INTEGER, anxpAllowBcast INTEGER, anxpBcastDirection INTEGER, anxpInputStartChar DisplayString, anxpInputStopChar DisplayString, anxpOutputStartChar DisplayString, anxpOutputStopChar DisplayString, anxpIxanyFlowCtl INTEGER, anxpLongBreak INTEGER, anxpShortBreak INTEGER, anxpForwardTimer INTEGER, anxpForwardCount INTEGER, anxpImask7Bits INTEGER, anxpAttnChar DisplayString, anxpInputBufSize INTEGER, anxpInputIsActivity INTEGER, anxpOutputIsActivity INTEGER, anxpInactivityTimer INTEGER, anxpResetIdleTimer INTEGER, anxpCliInactivity INTEGER, anxpCliSecurity INTEGER, anxpConnectSecurity INTEGER, anxpPortServerSecurity INTEGER, anxpPortPassword DisplayString, anxpUserName DisplayString, anxpDedicatedAddr IpAddress, anxpDedicatedPort DisplayString, anxpPrompt DisplayString, anxpTermVar DisplayString, anxpNewLineTerm INTEGER, anxpEcho INTEGER, anxpMapToLower INTEGER, anxpMapToUpper INTEGER, anxpHardwareTabs INTEGER, anxpCharErase INTEGER, anxpLineErase INTEGER, anxpEraseChar DisplayString, anxpEraseWord DisplayString, anxpEraseLine DisplayString, anxpRedisplayLine DisplayString, anxpToggleOutput DisplayString, anxpTelnetEscape DisplayString, anxpNeedDsr INTEGER, anxpTelnetCRLF INTEGER, anxpLatbEnable INTEGER, anxpSlipSecure INTEGER, anxpNetLocalAddr IpAddress, anxpNetRemoteAddr IpAddress, anxpSlipSubnetMask IpAddress, anxpSlipLoadDumpHost IpAddress, anxpNetMetric INTEGER, anxpSlipAllowDump INTEGER, anxpSlipDoCompression INTEGER, anxpSlipAllowCompression INTEGER, anxpSlipMtuSize INTEGER, anxpSlipNoIcmp INTEGER, anxpSlipTos INTEGER, anxpPppMru INTEGER, anxpPppAcm INTEGER, anxpPppSecurityProto INTEGER, anxpPppUserRemote DisplayString, anxpPppPasswdRemote DisplayString, anxpLatAuthGroupVal DisplayString, anxpPppDialupAddr INTEGER, anxpBanner INTEGER, anxpPsHistory INTEGER, anxpLocation DisplayString, anxpType INTEGER, anxpCliImask7 INTEGER } anxpPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique number from 1 to totalPorts that identifies each serial port." ::= { portEntry 1 } anxpMode OBJECT-TYPE SYNTAX INTEGER { cli(1), slave(2), adaptive(3), unused(4), slip(5), dedicated(6), ppp(7) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the mode for access to the serial line port. The default is cli" ::= { portEntry 2 } anxpCtrlLines OBJECT-TYPE SYNTAX INTEGER { none(1), dcddtr(2), ctsrts(3), both(4) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of hardware control used on the port: modem control (dcddtr), flow control (ctsrts), or both." ::= { portEntry 3 } anxpBidirModem OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the port is configured for adaptive use with a bidirectional modem." ::= { portEntry 4 } anxpAllowBcast OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls whether the serial port can receive administrative broadcast messages." ::= { portEntry 5 } anxpBcastDirection OBJECT-TYPE SYNTAX INTEGER { port(1), network(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the direction that an administrative broadcast message is sent. This parameter is valid only when the port is defined as a slave port by the anxpMode parameter." ::= { portEntry 6 } anxpInputStartChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "The control character sequence that restarts input if the charPortInFlowType parameter (in the char MIB) is set to xonXoff." ::= { portEntry 7 } anxpInputStopChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "The control character sequence that stops input if the charPortInFlowType parameter (in the char MIB) is set to xonXoff." ::= { portEntry 8 } anxpOutputStartChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "The control character sequence that restarts output if the charPortOutFlowType parameter (in the char MIB) is set to xonXoff." ::= { portEntry 9 } anxpOutputStopChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "The control character sequence that stops output if the charPortOutFlowType parameter (in the char MIB) is set to xonXoff." ::= { portEntry 10 } anxpIxanyFlowCtl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether any input character will be treated as a start (xon) character when output has been suspended by a stop (xoff) character." ::= { portEntry 11 } anxpLongBreak OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex returns the user to the CLI prompt after receiving a break greater than two seconds." ::= { portEntry 12 } anxpShortBreak OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex returns the user to the CLI prompt after receiving a break shorter than two seconds." ::= { portEntry 13 } anxpForwardTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the inter-character timer that sets the amount of time, in tens of milliseconds, that will elapse before forwarding the received data. The value of zero turns off the timer." ::= { portEntry 14 } anxpForwardCount OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the number of received characters buffered for the port by the Annex before forwarding the characters to the host or network." ::= { portEntry 15 } anxpImask7Bits OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, instructs the Annex to ignore the eighth bit of all received characters on the port." ::= { portEntry 16 } anxpAttnChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines a control character sequence as an attention character to return the user to the CLI prompt. The Annex-II only allows a single control character (eg. ^A), while the Annex3 and MicroAnnex allow a string of control characters to be defined (eg. ^A^B^Z)." ::= { portEntry 17 } anxpInputBufSize OBJECT-TYPE SYNTAX INTEGER (4..255) ACCESS read-write STATUS mandatory DESCRIPTION "The number of 256-byte blocks allocated to receive input characters from this port." ::= { portEntry 18 } anxpInputIsActivity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls whether received input characters are considered as activity for the port." ::= { portEntry 19 } anxpOutputIsActivity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Controls whether transmitted output characters are considered as activity for the port." ::= { portEntry 20 } anxpInactivityTimer OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time, in minutes, which a port can remain inactive before the Annex terminates all sessions and resets the port. A value of 0 disables the timer." ::= { portEntry 21 } anxpResetIdleTimer OBJECT-TYPE SYNTAX INTEGER { input(1), output(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether input or output resets the idle timer for the port." ::= { portEntry 22 } anxpCliInactivity OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time, in minutes, that the Annex waits before hanging up the serial port after it becomes idle. A value of 0 turns off the timer. A value of 255 means immediate, which causes the Annex to hang up the port immediately after exiting from the last job." ::= { portEntry 23 } anxpCliSecurity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether security is enabled for the port." ::= { portEntry 24 } anxpConnectSecurity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the host-based security policy is enabled for access from the port to the network." ::= { portEntry 25 } anxpPortServerSecurity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the host-based security policy is enabled for access to the port from the port server." ::= { portEntry 26 } anxpPortPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines a password for the port for local password protection." ::= { portEntry 27 } anxpUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "A string defining the user name for the user of the serial port." ::= { portEntry 28 } anxpDedicatedAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "When the anxpMode parameter is set to dedicated, this parameter defines the Internet address of the host to which this port can connect to." ::= { portEntry 29 } anxpDedicatedPort OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "The application name or TCP port number to which this port can connect when the anxpMode parameter is set to dedicated. The allowed application names are 'telnet', 'rlogin', 'login', 'call', and 'mls'." ::= { portEntry 30 } anxpPrompt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines a port-specific prompt." ::= { portEntry 31 } anxpTermVar OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "A string defining the type of terminal attached to the serial port." ::= { portEntry 32 } anxpNewLineTerm OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether a carriage return is echoed as just a carriage return (enabled), or whether the carriage return is echoed as a carriage return and line feed." ::= { portEntry 33 } anxpEcho OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex echoes all characters as they are received from the port." ::= { portEntry 34 } anxpMapToLower OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex translates all upper case characters to lower case as they are received from the port." ::= { portEntry 35 } anxpMapToUpper OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex translates all lower case characters to upper case as they are transmitted to the port." ::= { portEntry 36 } anxpHardwareTabs OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, this parameter allows the Annex to expand ASCII tab characters." ::= { portEntry 37 } anxpCharErase OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex echoes the character erase and word erase characters for a video terminal (enabled) or for a hard-copy terminal (disabled)." ::= { portEntry 38 } anxpLineErase OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex echoes the line erase character for a video terminal (enabled) or for a hard-copy terminal (disabled)." ::= { portEntry 39 } anxpEraseChar OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the character erase control character sequence." ::= { portEntry 40 } anxpEraseWord OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the word erase control character sequence." ::= { portEntry 41 } anxpEraseLine OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the line erase control character sequence." ::= { portEntry 42 } anxpRedisplayLine OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the reprint line control character sequence." ::= { portEntry 43 } anxpToggleOutput OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the flush control character used to flush the output buffer." ::= { portEntry 44 } anxpTelnetEscape OBJECT-TYPE SYNTAX DisplayString (SIZE (2)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the control character that returns the user to the telnet: prompt when running the CLI telnet command." ::= { portEntry 45 } anxpNeedDsr OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the DSR signal needs to be asserted when connecting to a slave port." ::= { portEntry 46 } anxpTelnetCRLF OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines what characters are transmitted out the port to the network when the End-of-Line character is sensed. 'enabled' means transmit Line-Feed and Carriage-Return. 'disabled' means transmit Carriage-Return and NULL. The default is enabled." ::= {portEntry 47 } anxpLatbEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Controls interpretation of LAT Data-B packets received from host." ::= { portEntry 48 } anxpSlipSecure OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "If anxEnableSecurity is not set, this parameter selects slip session logging. If anxEnableSecurity is set, this parameter permits slip access only from secure ports." ::= { portEntry 49 } anxpNetLocalAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address for the Annex's side of the point-to-point (SLIP or PPP) link." ::= { portEntry 50 } anxpNetRemoteAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address for the host at the remote end of the point-to-point (SLIP or PPP) link." ::= { portEntry 51 } anxpSlipSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The subnet mask for this SLIP interface." ::= { portEntry 52 } anxpSlipLoadDumpHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the host from which the Annex receives a load or to which the Annex sends a dump over the SLIP interface." ::= { portEntry 53 } anxpNetMetric OBJECT-TYPE SYNTAX INTEGER (0..64) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the hop count to the remote end of the SLIP or PPP interface." ::= { portEntry 54 } anxpSlipAllowDump OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines whether the Annex is allowed to dump across a SLIP link." ::= { portEntry 55 } anxpSlipDoCompression OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex will start TCP/IP header compression on this SLIP link." ::= { portEntry 56 } anxpSlipAllowCompression OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex will use TCP/IP header compression on this SLIP link only if the other end of the SLIP link initiates the compression." ::= { portEntry 57 } anxpSlipMtuSize OBJECT-TYPE SYNTAX INTEGER { large(1), small(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Force the compressed SLIP interface to use a Maximum Transmission Unit (MTU) of either 1024 bytes (large) or 256 bytes (small). The default is large." ::= { portEntry 58 } anxpSlipNoIcmp OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex will discard any ICMP packets directed to this SLIP link." ::= { portEntry 59 } anxpSlipTos OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex sends interactive traffic over this SLIP link before any other traffic." ::= { portEntry 60 } anxpPppMru OBJECT-TYPE SYNTAX INTEGER (64..1500) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the maximum receive unit in bytes. The default value is 1500." ::= { portEntry 61 } anxpPppAcm OBJECT-TYPE SYNTAX DisplayString (SIZE (8..10)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies which of the first 32 bytes (0x00, ... 0x1F) can be sent as clear text and which need to be escaped. A bit on in the mask indicates the character must be escaped. The mask should be specified as an 8 hex character string (0x1F000000 and 1F000000 are both acceptable)." ::= { portEntry 62 } anxpPppSecurityProto OBJECT-TYPE SYNTAX INTEGER { none(1), pap(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines which security protocol will be used to authenticate the remote user. This parameter must be set and the Annex enable_security (anxEnableSecurity) must be enabled before authentication is performed. The default is none" ::= { portEntry 63 } anxpPppUserRemote OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The username used by the Annex to identify itself if the remote PPP peer asks for authentication. Reading this parameter will return either if the username is defined or if the username is not defined." ::= { portEntry 64 } anxpPppPasswdRemote OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "The username used by the Annex to identify itself if the remote PPP peer asks for authentication. Reading this parameter will return either if the password is defined or if the password is not defined." ::= { portEntry 65 } anxpLatAuthGroupVal OBJECT-TYPE SYNTAX DisplayString (SIZE (32)) ACCESS read-write STATUS mandatory DESCRIPTION "This port parameter specifies which remote group codes are accessible to a user on a particular Annex port. Each port has its own set of group codes." ::= { portEntry 66 } anxpPppDialupAddr OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex requests the PPP dialup addresses from the host-based ACP." ::= { portEntry 67 } anxpBanner OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specifies whether the Annex banner and message- of-the-day are displayed on the port. The default is enabled." ::= { portEntry 68 } anxpPsHistory OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies how much data to buffer on a slave port." ::= { portEntry 69 } anxpLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-write STATUS mandatory DESCRIPTION "A descriptive string for a this port. This string is displayed by the CLI who command." ::= { portEntry 70 } anxpType OBJECT-TYPE SYNTAX INTEGER { dialin(1), hardwired(2), terminal(3), modem(4), printer(5) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of device attached to the port. The default is hardwired." ::= { portEntry 71 } anxpCliImask7 OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether input at the CLI is masked to 7 bitx. The default is disabled." ::= { portEntry 72 } -- the parallel port parameters anxpParaPorts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of parallel ports on this Annex." ::= { parallelport 1 } anxpParaPortTable OBJECT-TYPE SYNTAX SEQUENCE OF AnxpParaPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Table of parallel port parameters." ::= { parallelport 2 } anxpParaPortEntry OBJECT-TYPE SYNTAX AnxpParaPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Annex parallel port configuration parameters." INDEX { anxpParaPortIndex } ::= { anxpParaPortTable 1 } AnxpParaPortEntry ::= SEQUENCE { anxpParaPortIndex INTEGER, anxpParaPortHardwareTabs INTEGER, anxpParaPortMapToUpper INTEGER, anxpParaPortPrinterWidth INTEGER, anxpParaPortInterface INTEGER, anxpParaPortSpeed INTEGER } anxpParaPortIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "A unique number from 1 to anxpParaPorts that identifies each parallel port." ::= { anxpParaPortEntry 1 } anxpParaPortHardwareTabs OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex will send a tab character to the printer. If disabled, the tab is replaced with spaces." ::= { anxpParaPortEntry 2 } anxpParaPortMapToUpper OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When enabled, the Annex translates all lower case characters to upper case before transmitting the characters to the printer port." ::= { anxpParaPortEntry 3 } anxpParaPortPrinterWidth OBJECT-TYPE SYNTAX INTEGER (40..132) ACCESS read-write STATUS mandatory DESCRIPTION "The defined maximum number of characters per printer line." ::= { anxpParaPortEntry 4 } anxpParaPortInterface OBJECT-TYPE SYNTAX INTEGER { centronics(1), dataproducts(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of printer attached to the port." ::= { anxpParaPortEntry 5 } anxpParaPortSpeed OBJECT-TYPE SYNTAX INTEGER { normal(1), high-speed(2) } ACCESS read-write STATUS mandatory DESCRIPTION "The printer speed on the Micro-Annex." ::= { anxpParaPortEntry 6 } -- the Annex configuration parameters anxInetAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the Annex." ::= { annexconfig 1 } anxPrefLoadAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The preferred load address for the Annex." ::= { annexconfig 2 } anxPrefDumpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The preferred dump address for the Annex." ::= { annexconfig 3 } anxLoadDumpGateway OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of a gateway used when the preferred load or dump host is on a different network or subnet." ::= { annexconfig 4 } anxLoadDumpSeq OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Lists the available network interfaces and the order that the Annex uses them when doing a down-line load or up-line dump." ::= { annexconfig 5 } anxLoadBcast OBJECT-TYPE SYNTAX INTEGER { enabled(1), -- load broadcast enabled disabled(2) -- disabled } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines whether the Annex broadcasts for the config or the motd files if they were not found on the preferred load host." ::= { annexconfig 6 } anxServerCap OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether the Annex can act as a file server host for another Annex. The allowable values are 'all', 'none' (the default), or one or more of the following names separated by commas: 'config', 'motd', 'image'." ::= { annexconfig 7 } anxTimeBcast OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines whether the Annex broadcasts for the time if the preferred load host does not provide a time server." ::= { annexconfig 8 } anxBcastAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address used by the Annex when sending broadcasts." ::= { annexconfig 9 } anxSubnetMask OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet subnet mask." ::= { annexconfig 10 } anxAuthAgent OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex can send an ICMP Address Mask Reply to a received ICMP Address Mask Request." ::= { annexconfig 11 } anxMaxVcli OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of virtual CLI connections allowed by the Annex at any one time. 0 means the Annex does not allow VCLI connections. 255 allows the Annex to maintain an unlimited number of VCLI connections." ::= { annexconfig 12 } anxIpEncapType OBJECT-TYPE SYNTAX INTEGER { ethernet(1), ieee802(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether the Annex encapsulates IP packets in the Ethernet format or the IEEE 802.2/802.3 Data Link Layer format." ::= { annexconfig 13 } anxNameServer1Type OBJECT-TYPE SYNTAX INTEGER { none(1), ien116(2), dns(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The name service type used by the primary nameserver host." ::= { annexconfig 14 } anxNameServer1Addr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the primary nameserver host." ::= { annexconfig 15 } anxNameServer2Type OBJECT-TYPE SYNTAX INTEGER { none(1), ien116(2), dns(3) } ACCESS read-write STATUS mandatory DESCRIPTION "The name service type used by the secondary nameserver host." ::= { annexconfig 16 } anxNameServer2Addr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the secondary nameserver host." ::= { annexconfig 17 } anxNameServerBcast OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex broadcasts a name server request if the preferred name servers do not respond." ::= { annexconfig 18 } anxRwhod OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether the Annex listens for RWHO broadcasts when building its host table." ::= { annexconfig 19 } anxMinUniqueHostNames OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether the Annex minimum uniqueness feature is available." ::= { annexconfig 20 } anxHostTableSize OBJECT-TYPE SYNTAX INTEGER (0..251) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the number of entries in the Annex host table. 0 indicates no host table. 251 sets no limit on the size of the table." ::= { annexconfig 21 } anxRouted OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines whether the RIP-listener of the routing daemon on the Annex is enabled." ::= { annexconfig 22 } anxEnableSecurity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex security system is enabled." ::= { annexconfig 23 } anxPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "Setting this parameter changes the Annex's administration password. Reading this parameter will return either if the password is defined or if the password is not defined." ::= { annexconfig 24 } anxSecurServer1Addr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the primary host where the Annex sends its security requests." ::= { annexconfig 25 } anxSecurServer2Addr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the secondary host where the Annex sends its security requests." ::= { annexconfig 26 } anxNetTurnAround OBJECT-TYPE SYNTAX INTEGER (1..10) ACCESS read-write STATUS mandatory DESCRIPTION "The amount of time (in seconds) that the Annex waits for a response from a security server." ::= { annexconfig 27 } anxSecurBcast OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex will broadcast its security requests when neither of the preferred security servers are available." ::= { annexconfig 28 } anxVcliSecurity OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls whether the Annex performs user validation on the virtual CLI connections." ::= { annexconfig 29 } anxVcliPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines a password used by the Annex when setting up a virtual CLI connection." ::= { annexconfig 30 } anxAcpKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the Annex's encryption key used when exchanging messages between the Annex and the security server." ::= { annexconfig 31 } anxSysLogMask OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the priority levels of events logged in the Annex syslog file. The allowable values are 'all', 'none', or one or more of the following level names separated by commas: 'emergency', 'alert', 'critical', 'error', 'warning', 'notice', 'info', 'debug' " ::= { annexconfig 32 } anxSysLogFacility OBJECT-TYPE SYNTAX INTEGER { loglocal0(17), loglocal1(18), loglocal2(19), loglocal3(20), loglocal4(21), loglocal5(22), loglocal6(23), loglocal7(24) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the 4.3BSD syslog facility used in logging the Annex messages." ::= { annexconfig 33 } anxSysLogHost OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "The Internet address of the host configured to log Annex messages." ::= { annexconfig 34 } anxCliPrompt OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The string used by the Annex to prompt all CLI users." ::= { annexconfig 35 } anxMotdFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "The host file name that contains the message-of-the-day for the Annex." ::= { annexconfig 36 } anxTftpDirName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the directory name to be prepended to all files (boot image, motd, macros, etc.) when booting via TFTP." ::= { annexconfig 37 } anxTftpDumpName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-write STATUS mandatory DESCRIPTION "The full pathname of the TFTP dump file, if any." ::= { annexconfig 38 } anxTimeZone OBJECT-TYPE SYNTAX INTEGER (-1200..1200) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the timezone where the Annex resides in minutes west of GMT." ::= { annexconfig 39 } anxDaylightSavings OBJECT-TYPE SYNTAX INTEGER { us(1), australian(2), westeuropean(3), mideuropean(4), easteuropean(5), canadian(6), british(7), none(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Defines the daylight savings time for the geographic location of the Annex." ::= { annexconfig 40 } -- the LAT protocol parameters anxLatKey OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Annex specific LAT key used to enable or disable the LAT protocol." ::= { annexconfig 41 } anxCircuitTimer OBJECT-TYPE SYNTAX INTEGER (1..100) ACCESS read-write STATUS mandatory DESCRIPTION "The time interval in tens of milliseconds between the transmission of LAT packets." ::= { annexconfig 42 } anxFacilityNum OBJECT-TYPE SYNTAX INTEGER (0..32767) ACCESS read-write STATUS mandatory DESCRIPTION "The LAT facility number." ::= { annexconfig 43 } anxLatGroupVal OBJECT-TYPE SYNTAX DisplayString (SIZE (32)) ACCESS read-write STATUS mandatory DESCRIPTION "The Annex LAT group code for permitting access to LAT services. To access a specific LAT service, the Annex must have at least one enabled group code match the service's set group codes. The Annex will not maintain any information about unauthorized services. The value is displayed as a string of hex characters with each bit defining whether a specific group is enabled or disabled." ::= { annexconfig 44 } anxKeepAliveTimer OBJECT-TYPE SYNTAX INTEGER (10..255) ACCESS read-write STATUS mandatory DESCRIPTION "The time interval, in seconds, between the transmission of identification packets during times of network inactivity." ::= { annexconfig 45 } anxReXmitLimit OBJECT-TYPE SYNTAX INTEGER (4..120) ACCESS read-write STATUS mandatory DESCRIPTION "The number of times to retransmit a packet before notifying the user of a network failure." ::= { annexconfig 46 } anxServerName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "A string of up to 16 characters used to name the Annex in the LAT protocol." ::= { annexconfig 47 } anxServiceLimit OBJECT-TYPE SYNTAX INTEGER (16..2048) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter defines the upper bound on the number of services that the Annex can maintain in its local service table." ::= { annexconfig 48 } anxConfigFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the host file that contains the alias and menu entries." ::= { annexconfig 49 } anxLatVcliGroupVal OBJECT-TYPE SYNTAX DisplayString (SIZE (32)) ACCESS read-write STATUS mandatory DESCRIPTION "This Annex parameter specifies which remote group codes are accessible to virtual cli users. All virtual cli users have the same group code. The value is displayed as a string of hex characters with each bit defining whether a specific group is enabled or disabled." ::= { annexconfig 50 } anxLatQueueMax OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Defines the maximum number of host requests (HIC's) that the Annex will save in its internal queue when the requested resource is not available (port busy)." ::= { annexconfig 51 } anxLatLocation OBJECT-TYPE SYNTAX DisplayString (SIZE (0..32)) ACCESS read-write STATUS mandatory DESCRIPTION "A string of up to 32 characters used to identify the location of the Annex for the LAT protocol." ::= { annexconfig 52 } anxDisabledModules OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) ACCESS read-write STATUS mandatory DESCRIPTION "Defines which selectable modules are currently disabled. The allowable values are 'all', 'none' or one or more of the following names separated by commas: 'admin', 'lat', 'ppp', 'slip', 'snmp', 'nameserver', 'cli-edit'. If this is a MicroAnnex ELS, the values 'ppp' and 'slip' are not valid." ::= { annexconfig 53 } anxSysLogPort OBJECT-TYPE SYNTAX INTEGER (0..64) ACCESS read-write STATUS mandatory DESCRIPTION "Specifies the Annex port number where syslog messages are sent. If set to 0, syslog messages are not sent to an Annex port. This is independent of any host-based syslogging that may be enabled. The maximum port number allowed will depend on the highest numbered port on the specific Annex." ::= { annexconfig 54 } -- the annex commands anxcBoot OBJECT-TYPE SYNTAX INTEGER { immediate(1), delayed(2), dumpboot(3), diagnosticboot(4), abortschedule(5), quiet(6) } ACCESS read-write STATUS mandatory DESCRIPTION "The type of boot to be performed. To initiate a dump, this parameter needs to be set by the management station. The values stored in anxcBootImage, anxcBootTime, and anxcBootMsg are used as needed, depending on the boot type." ::= { annexcmds 1 } anxcBootImage OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-write STATUS mandatory DESCRIPTION "The name of the image file to be used with the boot command." ::= { annexcmds 2 } anxcBootTime OBJECT-TYPE SYNTAX DisplayString (SIZE (5..10)) ACCESS read-write STATUS mandatory DESCRIPTION "The time at which the next boot is scheduled in HH:MM format." ::= { annexcmds 3 } anxcBootMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-write STATUS mandatory DESCRIPTION "The broadcast message to be displayed when the next boot is performed." ::= { annexcmds 4 } anxcReset OBJECT-TYPE SYNTAX INTEGER { all(1), macros(2), motd(3), nameserver(4), security(5), printerport(6), serialports(7), virtualports(8) } ACCESS read-write STATUS mandatory DESCRIPTION "Writing a value to this object causes the annex to reset the appropriate subsystem." ::= { annexcmds 5 } anxcBcast OBJECT-TYPE SYNTAX INTEGER { all(1), serial(2), virtual(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Writing a value to this object causes the annex to send the message in anxcBcastMsg to the specified port set." ::= { annexcmds 6 } anxcBcastMsg OBJECT-TYPE SYNTAX DisplayString (SIZE (0..100)) ACCESS read-write STATUS mandatory DESCRIPTION "The message to be broadcast to the Annex ports." ::= { annexcmds 7 } END