AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Altiga-Networks-Inc » ALTIGA-HARDWARE-STATS-MIB » Objects

ALTIGA-HARDWARE-STATS-MIB.mib object view, vendor Altiga-Networks-Inc

Introduction

Most network devices and programs ship with so-called MIB files to describe the parameters and meanings (i.e.: friendly names) which are available for monitoring via SNMP.
ActiveXperts Network Monitor 2024 can import vendor-specific MIB files, so it can be used to monitor specific OID's (Object Identifiers). This way, you can monitor your devices, computers, etc. by selecting your relevant OID's by name.

ActiveXperts Network Monitor 2024 can import MIB file ALTIGA-HARDWARE-STATS-MIB and use it to monitor vendor specific OID's.

ALTIGA-HARDWARE-STATS-MIB file content

Object view of ALTIGA-HARDWARE-STATS-MIB:

Scalar Object
alHardwareCpuVoltage .1.3.6.1.4.1.3076.2.1.2.22.1.1
The current CPU voltage in centivolts.
alHardwareCpuVoltageAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.2
The alarm status for CPU voltage. This alarm will fired when the CPU voltage is detected out of configured range.
alHardwareCpuVoltageCount .1.3.6.1.4.1.3076.2.1.2.22.1.3
The number of alarm events for CPU voltage.
alHardwareCpuVoltageTime .1.3.6.1.4.1.3076.2.1.2.22.1.4
The sysUptime at the time of the last change of alarm status for CPU voltage.
alHardwarePs1Voltage3v .1.3.6.1.4.1.3076.2.1.2.22.1.5
The current 3V voltage of Power Supply 1 in centivolts.
alHardwarePs1Voltage3vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.6
The alarm status for PS1 3v voltage. This alarm will fired when the 3v power supply 1 voltage is detected out of configured range.
alHardwarePs1Voltage3vCount .1.3.6.1.4.1.3076.2.1.2.22.1.7
The number of alarm events for PS1 3v voltage.
alHardwarePs1Voltage3vTime .1.3.6.1.4.1.3076.2.1.2.22.1.8
The sysUptime at the time of the last change of alarm status for PS1 3v voltage.
alHardwarePs1Voltage5v .1.3.6.1.4.1.3076.2.1.2.22.1.9
The current 5V voltage of Power Supply 1 in centivolts.
alHardwarePs1Voltage5vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.10
The alarm status for PS1 5v voltage. This alarm will fired when the 5v power supply 1 voltage is detected out of configured range.
alHardwarePs1Voltage5vCount .1.3.6.1.4.1.3076.2.1.2.22.1.11
The number of alarm events for PS1 5v voltage.
alHardwarePs1Voltage5vTime .1.3.6.1.4.1.3076.2.1.2.22.1.12
The sysUptime at the time of the last change of alarm status for PS1 5v voltage.
alHardwarePs2Voltage3v .1.3.6.1.4.1.3076.2.1.2.22.1.13
The current 3V voltage of Power Supply 2 in centivolts.
alHardwarePs2Voltage3vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.14
The alarm status for PS2 3v voltage. This alarm will fired when the 3v power supply 2 voltage is detected out of configured range.
alHardwarePs2Voltage3vCount .1.3.6.1.4.1.3076.2.1.2.22.1.15
The number of alarm events for PS2 3v voltage.
alHardwarePs2Voltage3vTime .1.3.6.1.4.1.3076.2.1.2.22.1.16
The sysUptime at the time of the last change of alarm status for PS2 3v voltage.
alHardwarePs2Voltage5v .1.3.6.1.4.1.3076.2.1.2.22.1.17
The current 5V voltage of Power Supply 2 in centivolts.
alHardwarePs2Voltage5vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.18
The alarm status for PS2 5v voltage. This alarm will fired when the 5v power supply 2 voltage is detected out of configured range.
alHardwarePs2Voltage5vCount .1.3.6.1.4.1.3076.2.1.2.22.1.19
The number of alarm events for PS2 5v voltage.
alHardwarePs2Voltage5vTime .1.3.6.1.4.1.3076.2.1.2.22.1.20
The sysUptime at the time of the last change of alarm status for PS2 5v voltage.
alHardwareBoardVoltage3v .1.3.6.1.4.1.3076.2.1.2.22.1.21
The current 3V voltage of the mainboard in centivolts.
alHardwareBoardVoltage3vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.22
The alarm status for the mainboard 3v voltage. This alarm will fired when the 3v mainboard voltage is detected out of configured range.
alHardwareBoardVoltage3vCount .1.3.6.1.4.1.3076.2.1.2.22.1.23
The number of alarm events for the mainboard 3v voltage.
alHardwareBoardVoltage3vTime .1.3.6.1.4.1.3076.2.1.2.22.1.24
The sysUptime at the time of the last change of alarm status for the mainboard 3v voltage.
alHardwareBoardVoltage5v .1.3.6.1.4.1.3076.2.1.2.22.1.25
The current 5V voltage of the mainboard in centivolts.
alHardwareBoardVoltage5vAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.26
The alarm status for the mainboard 5v voltage. This alarm will fired when the 5v mainboard voltage is detected out of configured range.
alHardwareBoardVoltage5vCount .1.3.6.1.4.1.3076.2.1.2.22.1.27
The number of alarm events for the mainboard 5v voltage.
alHardwareBoardVoltage5vTime .1.3.6.1.4.1.3076.2.1.2.22.1.28
The sysUptime at the time of the last change of alarm status for the mainboard 5v voltage.
alHardwareCpuTemp .1.3.6.1.4.1.3076.2.1.2.22.1.29
The current CPU temperature in degrees C.
alHardwareCpuTempAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.30
The alarm status for the CPU temperature. This alarm will fired when the CPU temperature is detected out of configured range.
alHardwareCpuTempCount .1.3.6.1.4.1.3076.2.1.2.22.1.31
The number of alarm events for the CPU temperature.
alHardwareCpuTempTime .1.3.6.1.4.1.3076.2.1.2.22.1.32
The sysUptime at the time of the last change of alarm status for the CPU temperature.
alHardwareCageTemp .1.3.6.1.4.1.3076.2.1.2.22.1.33
The current cage temperature in degrees C.
alHardwareCageTempAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.34
The alarm status for the cage temperature. This alarm will fired when the cage temperature is detected out of configured range.
alHardwareCageTempCount .1.3.6.1.4.1.3076.2.1.2.22.1.35
The number of alarm events for the cage temperature.
alHardwareCageTempTime .1.3.6.1.4.1.3076.2.1.2.22.1.36
The sysUptime at the time of the last change of alarm status for the cage temperature.
alHardwareFan1Rpm .1.3.6.1.4.1.3076.2.1.2.22.1.37
The current speed of fan 1 in RPM.
alHardwareFan1RpmAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.38
The alarm status for fan 1 RPM. This alarm will fired when fan 1 RPM is detected out of configured range.
alHardwareFan1RpmCount .1.3.6.1.4.1.3076.2.1.2.22.1.39
The number of alarm events for fan 1 RPM.
alHardwareFan1RpmTime .1.3.6.1.4.1.3076.2.1.2.22.1.40
The sysUptime at the time of the last change of alarm status for fan 1 RPM.
alHardwareFan2Rpm .1.3.6.1.4.1.3076.2.1.2.22.1.41
The current speed of fan 2 in RPM.
alHardwareFan2RpmAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.42
The alarm status for fan 2 RPM. This alarm will fired when fan 2 RPM is detected out of configured range.
alHardwareFan2RpmCount .1.3.6.1.4.1.3076.2.1.2.22.1.43
The number of alarm events for fan 2 RPM.
alHardwareFan2RpmTime .1.3.6.1.4.1.3076.2.1.2.22.1.44
The sysUptime at the time of the last change of alarm status for fan 2 RPM.
alHardwareFan3Rpm .1.3.6.1.4.1.3076.2.1.2.22.1.45
The current speed of fan 3 in RPM.
alHardwareFan3RpmAlarm .1.3.6.1.4.1.3076.2.1.2.22.1.46
The alarm status for fan 3 RPM. This alarm will fired when fan 3 RPM is detected out of configured range.
alHardwareFan3RpmCount .1.3.6.1.4.1.3076.2.1.2.22.1.47
The number of alarm events for fan 3 RPM.
alHardwareFan3RpmTime .1.3.6.1.4.1.3076.2.1.2.22.1.48
The sysUptime at the time of the last change of alarm status for fan 3 RPM.
alHardwarePs1Type .1.3.6.1.4.1.3076.2.1.2.22.1.49
The type of power supply for Power Supply slot 1.
alHardwarePs2Type .1.3.6.1.4.1.3076.2.1.2.22.1.50
The type of power supply for Power Supply slot 2.
alHardwareSlot1Card .1.3.6.1.4.1.3076.2.1.2.22.1.51
The type of card in slot 1.
alHardwareSlot2Card .1.3.6.1.4.1.3076.2.1.2.22.1.52
The type of card in slot 2.
alHardwareSlot3Card .1.3.6.1.4.1.3076.2.1.2.22.1.53
The type of card in slot 3.
alHardwareSlot4Card .1.3.6.1.4.1.3076.2.1.2.22.1.54
The type of card in slot 4.
alHardwareSlot1Operational .1.3.6.1.4.1.3076.2.1.2.22.1.55
The operational status of card in slot 1.
alHardwareSlot2Operational .1.3.6.1.4.1.3076.2.1.2.22.1.56
The operational status of card in slot 2.
alHardwareSlot3Operational .1.3.6.1.4.1.3076.2.1.2.22.1.57
The operational status of card in slot 3.
alHardwareSlot4Operational .1.3.6.1.4.1.3076.2.1.2.22.1.58
The operational status of card in slot 4.
alHardwareRamSize .1.3.6.1.4.1.3076.2.1.2.22.1.59
The amount of memory, in MB on the concentrator.
alHardwareChassis .1.3.6.1.4.1.3076.2.1.2.22.1.60
The type of VPN Concentrator this is.
alHardwareCpuVoltageNominal .1.3.6.1.4.1.3076.2.1.2.22.1.61
The nominal CPU voltage in centivolts for the concentrator.
alHardwareClientEthPrivSwitch .1.3.6.1.4.1.3076.2.1.2.22.1.62
Whether or not the 3002 Hardware Client has an Ethernet Switch for the private interface.
alHardwareSerialNumber .1.3.6.1.4.1.3076.2.1.2.22.1.63
Unit serial number.
Object Identifier
altigaHardwareStatsMibModule .1.3.6.1.4.1.3076.1.1.27.2
The Altiga Hardware Statistics MIB models counters and objects that are of management interest for the hardware. Acronyms The following acronyms are used in this document: CPU: Central Processing Unit MB: Megabyte MIB: Management Information Base PS: Power Supply RPM: Revolutions Per Minute SEP: Scalable Encryption Processor WAN: Wide Area Network
alStatsHardwareGlobal .1.3.6.1.4.1.3076.2.1.2.22.1
altigaHardwareStatsMibConformance .1.3.6.1.4.1.3076.1.1.27.2.1
altigaHardwareStatsMibCompliances .1.3.6.1.4.1.3076.1.1.27.2.1.1
Group
altigaHardwareStatsGroup .1.3.6.1.4.1.3076.2.1.1.1.22.2
The objects for Hardware statistics.