CABH-CTP-MIB file content

Object view of CABH-CTP-MIB:

Scalar Object
cabhCtpSetToFactory .1.3.6.1.4.1.4491.2.4.5.1.1.1
Setting this object to true(1) causes all the tables in the CTP MIB to be cleared, and all CTP MIB objects with default values set back to those default values. Reading this object always returns false(2).
cabhCtpConnSrcIpType .1.3.6.1.4.1.4491.2.4.5.1.2.1
The IP Address type used as the source address for the Connection Speed Test.
cabhCtpConnSrcIp .1.3.6.1.4.1.4491.2.4.5.1.2.2
The IP Address used as the source address for the Connection Speed Test. The default value is the value of cabhCdpServerRouter (192.168.0.1).
cabhCtpConnDestIpType .1.3.6.1.4.1.4491.2.4.5.1.2.3
The IP Address Type for the CTP Connection Speed Tool destination address.
cabhCtpConnDestIp .1.3.6.1.4.1.4491.2.4.5.1.2.4
The IP Address used as the destination address for the Connection Speed Test.
cabhCtpConnProto .1.3.6.1.4.1.4491.2.4.5.1.2.5
The protocol used in the Connection Speed Test. TCP testing is optional.
cabhCtpConnNumPkts .1.3.6.1.4.1.4491.2.4.5.1.2.6
The number of packets the CTP is to send when triggered to execute the Connection Speed Tool.
cabhCtpConnPktSize .1.3.6.1.4.1.4491.2.4.5.1.2.7
The size of the test frames.
cabhCtpConnTimeOut .1.3.6.1.4.1.4491.2.4.5.1.2.8
The timeout value for the response. A value of zero indicates no time out and can be used for TCP only.
cabhCtpConnControl .1.3.6.1.4.1.4491.2.4.5.1.2.9
The control for the Connection Speed Tool. Setting this object to start(1) causes the Connection Speed Tool to execute. Setting this object to abort(2) causes the Connection Speed Tool to stop running. This parameter should only be set via SNMP.
cabhCtpConnStatus .1.3.6.1.4.1.4491.2.4.5.1.2.10
The status of the Connection Speed Tool.
cabhCtpConnPktsSent .1.3.6.1.4.1.4491.2.4.5.1.2.11
The number of packets the CTP sent after it was triggered to execute the Connection Speed Tool.
cabhCtpConnPktsRecv .1.3.6.1.4.1.4491.2.4.5.1.2.12
The number of packets the CTP received after it executed the Connection Speed Tool.
cabhCtpConnRTT .1.3.6.1.4.1.4491.2.4.5.1.2.13
The resulting round trip time for the set of packets sent to and received from the target LAN IP Device.
cabhCtpConnThroughput .1.3.6.1.4.1.4491.2.4.5.1.2.14
The average round-trip throughput measured in kilobits per second.
cabhCtpPingSrcIpType .1.3.6.1.4.1.4491.2.4.5.1.3.1
The IP Address Type for CTP Ping Tool source address.
cabhCtpPingSrcIp .1.3.6.1.4.1.4491.2.4.5.1.3.2
The IP Address used as the source address for the Ping Test. The default value is the value of CabhCdpServerRouter (192.168.0.1).
cabhCtpPingDestIpType .1.3.6.1.4.1.4491.2.4.5.1.3.3
The IP Address Type for the CTP Ping Tool destination address.
cabhCtpPingDestIp .1.3.6.1.4.1.4491.2.4.5.1.3.4
The Destination IP Address used as the destination address for the Ping Test.
cabhCtpPingNumPkts .1.3.6.1.4.1.4491.2.4.5.1.3.5
The number of packets to send to each host.
cabhCtpPingPktSize .1.3.6.1.4.1.4491.2.4.5.1.3.6
The size of the test frames.
cabhCtpPingTimeBetween .1.3.6.1.4.1.4491.2.4.5.1.3.7
The time between sending one ping and the next.
cabhCtpPingTimeOut .1.3.6.1.4.1.4491.2.4.5.1.3.8
The time out for ping response (ICMP reply) for a single transmitted ping message (ICMP request).
cabhCtpPingControl .1.3.6.1.4.1.4491.2.4.5.1.3.9
The control for the Ping Tool. Setting this object to start(1) causes the Ping Tool to execute. Setting this object to abort(2) causes the Ping Tool to stop running. This parameter should only be set via SNMP.
cabhCtpPingStatus .1.3.6.1.4.1.4491.2.4.5.1.3.10
The status of the Ping Tool.
cabhCtpPingNumSent .1.3.6.1.4.1.4491.2.4.5.1.3.11
The number of Pings sent
cabhCtpPingNumRecv .1.3.6.1.4.1.4491.2.4.5.1.3.12
The number of pings received.
cabhCtpPingAvgRTT .1.3.6.1.4.1.4491.2.4.5.1.3.13
The resulting average of round trip times for acknowledged packets.
cabhCtpPingMaxRTT .1.3.6.1.4.1.4491.2.4.5.1.3.14
The resulting maximum of round trip times for acknowledged packets.
cabhCtpPingMinRTT .1.3.6.1.4.1.4491.2.4.5.1.3.15
The resulting minimum of round trip times for acknowledged packets.
cabhCtpPingNumIcmpError .1.3.6.1.4.1.4491.2.4.5.1.3.16
Number of ICMP errors.
cabhCtpPingIcmpError .1.3.6.1.4.1.4491.2.4.5.1.3.17
The last ICMP error.
Object Identifier
cabhCtpMib .1.3.6.1.4.1.4491.2.4.5
This MIB module defines the diagnostic controls offered by the CableHome Test Portal (CTP). Acknowledgements: Roy Spitzer - Consultant to CableLabs Mike Mannette - Consultant to CableLabs Randy Dunton - Intel Dmitrii Loukianov - Intel Wes Peters - DoBox, Inc. Chris Zacker Broadcom
cabhCtpObjects .1.3.6.1.4.1.4491.2.4.5.1
cabhCtpBase .1.3.6.1.4.1.4491.2.4.5.1.1
cabhCtpConnSpeed .1.3.6.1.4.1.4491.2.4.5.1.2
cabhCtpPing .1.3.6.1.4.1.4491.2.4.5.1.3
cabhCtpNotification .1.3.6.1.4.1.4491.2.4.5.2.0
cabhCtpConformance .1.3.6.1.4.1.4491.2.4.5.3
cabhCtpCompliances .1.3.6.1.4.1.4491.2.4.5.3.1
cabhCtpGroups .1.3.6.1.4.1.4491.2.4.5.3.2
Group
cabhCtpGroup .1.3.6.1.4.1.4491.2.4.5.3.2.1
Group of objects for CableHome CTP MIB.