| cfmFcipEntityExtTcpKeepAliveTO | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.1 | 
    
    
      | 
        The TCP Keep alive timeout for all links within this
        entity. 
       | 
    
    
      | cfmFcipEntityExtTcpMaxReTx | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.2 | 
    
    
      | 
        The Maximum number of times that the same item of data
        will be retransmitted over a TCP connection. If delivery
        is not acknowledged after this number of retransmissions
        then the TCP connection is terminated. 
       | 
    
    
      | cfmFcipEntityExtPMTUEnable | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.3 | 
    
    
      | 
        The path MTU discovery is enabled if the value of
        this object is true(1), else it is disabled, and
        has the value false(2). 
       | 
    
    
      | cfmFcipEntityExtPMTUResetTO | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.4 | 
    
    
      | 
        The time interval for which the discovered pathMTU
        is valid, before MSS reverts back to the negotiated
        TCP value. This object is writeble only if
        cfmFcipEntityExtPMTUEnable is 'true'. 
       | 
    
    
      | cfmFcipEntityExtTcpMinRTO | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.5 | 
    
    
      | 
        The TCP minimum retransmit timeout for all the links on
        this entity. 
       | 
    
    
      | cfmFcipEntityExtTcpSendBufSize | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.6 | 
    
    
      | 
        The aggregate TCP send window for all TCP connections on all
        Links within this entity. This value is used for Egress
        Flow Control. When the aggregate of the data queued
        on all connections within this entity reaches this value,
        the sender is flow controlled. 
       | 
    
    
      | cfmFcipEntityExtTcpMaxBW | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.7 | 
    
    
      | 
        This is an estimate of the Bandwidth of the network pipe
        used for the B-D product computation, which lets us derive
        the TCP receive window to advertise.
        The cfmFcipEntityExtTcpMaxBW,cfmFcipEntityExtTcpMinAvailBW,
        cfmFcipEntityExtTcpRndTrpTimeEst must be set in the same
        SNMP set request. SET operation would fail if this object
        is set individually.
       | 
    
    
      | cfmFcipEntityExtTcpMinAvailBW | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.8 | 
    
    
      | 
        The minimum avilable bandwidth for the TCP connections
        on the Links within this entity.
        The cfmFcipEntityExtTcpMaxBW,cfmFcipEntityExtTcpMinAvailBW,
        cfmFcipEntityExtTcpRndTrpTimeEst must be set in the same
        SNMP set request. SET operation would fail if this object
        is set individually. 
       | 
    
    
      | cfmFcipEntityExtTcpRndTrpTimeEst | 
      .1.3.6.1.4.1.9.9.329.1.1.1.1.9 | 
    
    
      | 
        This is an estimate of the round trip delay of the network
        pipe used for the B-D product computation, which lets us
        derive the TCP receive window to advertise.
        The cfmFcipEntityExtTcpMaxBW,cfmFcipEntityExtTcpMinAvailBW,
        cfmFcipEntityExtTcpRndTrpTimeEst must be set in the same
        SNMP set request. SET operation would fail if this object
        is set individually. 
       | 
    
    
      | cfmFcipLinkExtPassiveMode | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.1 | 
    
    
      | 
        If the value is set to 'false' this link endpoint actively
        tries to connect to the peer. If it is set to 'true' the link
        endpoint waits for the peer to connect to it. 
       | 
    
    
      | cfmFcipLinkExtNumTcpConn | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.2 | 
    
    
      | 
        The maximum number of TCP connections allowed on this
        link. 
       | 
    
    
      | cfmFcipLinkExtCheckTimestamp | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.3 | 
    
    
      | 
        The value is 'true', if the timestamp in FCIP header
        is to checked. If 'false' the timestamp is ignored. 
       | 
    
    
      | cfmFcipLinkExtTimestampTolerance | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.4 | 
    
    
      | 
        The accepted time difference between the local time
        and the timestamp value received in the FCIP header.
        By default this value will be EDTOV/2. EDTOV is the
        Error_Detect_Timeout Value used for Fibre channel Ports
        as the timeout value for detecting an error condition.
       | 
    
    
      | cfmFcipLinkExtTcpRemPort | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.5 | 
    
    
      | 
        The remote TCP port to which the local FCIP entity will
        connect if and when it initiates a TCP connection setup
        for this link. 
       | 
    
    
      | cfmFcipLinkExtLocalBPortEnable | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.6 | 
    
    
      | 
        If the value is set to 'true', the B port mode is enabled
        on the local FCIP link. If set to 'false' the B port mode
        is disabled. 
       | 
    
    
      | cfmFcipLinkExtSpecialFrameEnable | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.7 | 
    
    
      | 
        If the value is set to 'true', the TCP active opener
        initiates FCIP special frames and the TCP passive
        opener responds to the FCIP special frames.
        If it is set to 'false', the FCIP special frames are
        neither generated nor responded to. 
       | 
    
    
      | cfmFcipLinkExtBPortKAEnable | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.8 | 
    
    
      | 
        If the value is set to 'true', a message is
        sent in response to a (Fibre Channel) ELS Echo
        frame received from the peer. Some B Port
        implementations use ELS Echo request/response frames
        as Link Keep Alive.
        If it is set to 'false', this response is not
        generated.
        This object is valid only if the
        cfmFcipLinkExtLocalBPortEnable is  'true'. 
       | 
    
    
      | cfmFcipLinkExtCntrlQOSField | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.9 | 
    
    
      | 
        The value to be set for the TOS field in IP header
        for the TCP control connection.
        The cfmFcipLinkExtCntrlQOSField,cfmFcipLinkExtDataQOSField
        must be set in the same SNMP set request. SET operation would
        fail if this object is set individually. 
       | 
    
    
      | cfmFcipLinkExtDataQOSField | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.10 | 
    
    
      | 
        The value to be set for the TOS field in IP header
        for the TCP Data connection.
        The cfmFcipLinkExtCntrlQOSField,cfmFcipLinkExtDataQOSField
        must be set in the same SNMP set request. SET operation would
        fail if this object is set individually. 
       | 
    
    
      | cfmFcipLinkExtEthIfIndex | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.11 | 
    
    
      | 
        The ifIndex of the interface on which this FCIP link was
        initiated. 
       | 
    
    
      | cfmFcipLinkExtWriteAccelerator | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.12 | 
    
    
      | 
        The Write accelerator allows for enhancing SCSI write
        performance.
        If 'true', the FCIP Write accelerator is enabled on this link
        If 'false' it is disabled.
       | 
    
    
      | cfmFcipLinkExtIPComp | 
      .1.3.6.1.4.1.9.9.329.1.1.2.1.13 | 
    
    
      | 
        The configuration for the IP compression.
        'none'                 - ip compression is disabled.
        'highCompressionRatio' - indicates better compression
        performance at the cost of lower throughput.
        'highThroughput'       - indicates better throughput at
        the cost of lower compression performance.
        
       |