The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CHASSIS-MIB.


Vendor: Enterasys Networks Inc
Mib: CHASSIS-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
CHASSIS-MIB DEFINITIONS ::= BEGIN

        --  ctron-chassis-mib.txt
        --  Revision: 1.07.00
        --  Part Number:  2170548
        --  Date: January 31, 1997

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific chassis MIB.
        --
        --  This module will be extended, as needed.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems

        IMPORTS
                NetworkAddress, Counter, TimeTicks
                        FROM RFC1155-SMI
                chassis
                        FROM CTRON-MIB-NAMES
                DisplayString
                        FROM RFC1213-MIB
                OBJECT-TYPE
                        FROM RFC-1212;


        --  This MIB module uses the extended OBJECT-TYPE macro as defined
        --  RFC 1212

        --  Textual convention


        -- DisplayString ::= OCTET STRING
        --  This data type is used to model textual information taken from
        --  the NVT ASCII character set.  By convention, objects with this
        --  syntax, unless explicitly stated, are declared as having:
        --
        --  SIZE (0..255)

        --  chType is, in generic terms, similar to sysObjectID in
        --  MIB-II.  It is defined for the sake of completeness, and
        --  in order to negate dependencies on other MIBs.

        chType  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Identifies the type of hub-based or standalone device.
                 A vendor's authoritative identification of this
                 chassis or device.  By convention, this value is
                 allocated within the SMI enterprises subtree(1.3.6.1.4.1),
                 and provides an easy and unambiguous means for
                 determining `what kind of box' is being managed.  If this
                 information is not present or unknown, its value should
                 be set to the OBJECT IDENTIFIER { 0 0 }, which is a
                 syntactically valid object identifier."
            ::= { chassis 1 }

        chBackplaneTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChBackplaneEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of backplanes resident in this chassis."
            ::= { chassis 2 }

        chBackplaneEntry  OBJECT-TYPE
            SYNTAX  ChBackplaneEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A backplane entry containing objects for a particular
                 backplane."
            INDEX   { chBackplaneID }
            ::= { chBackplaneTable 1 }

        ChBackplaneEntry  ::=
            SEQUENCE {
                chBackplaneID
                    INTEGER,
                chBackplaneType
                    OBJECT IDENTIFIER
            }

        chBackplaneID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "An unique value identifying a backplane within the
                 chassis."
            ::= { chBackplaneEntry 1 }

        chBackplaneType  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "An authoritative identification that is specific to
                 the particular media being used to realize the
                 backplane.  For example, if the backplane is realized
                 by an Ethernet, then the value of this object refers
                 to a well known OID defined for Ethernet.  If this
                 information is not present or unknown, its value
                 should be set to OBJECT IDENTIFIER { 0 0 }, which
                 is a syntactically valid object identifier."
            ::= { chBackplaneEntry 2 }

        chNumSlots  OBJECT-TYPE
            SYNTAX  INTEGER (0..64)
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Number of slots in a chassis.  For bounded, slot-less
                 systems, the value of this object shall be zero(0)."
            ::= { chassis 3 }

        --  Component Table and Definitions
        --  Components are instances of functional devices.  For
        --  example, if two routers and three bridges were installed
        --  in a chassis, said chassis accommodates five components.

        chCompTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChCompEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of components installed in this chassis."
            ::= { chassis 4 }

        chCompEntry  OBJECT-TYPE
            SYNTAX  ChCompEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A component entry containing objects for a particular
                 component."
            INDEX   { chCompID }
            ::= { chCompTable 1 }

        ChCompEntry  ::= 
            SEQUENCE {
                chCompID
                    INTEGER,
                chCompAdminStatus
                    INTEGER,
                chCompArg
                    OCTET STRING,
                chCompType
                    OBJECT IDENTIFIER,
                chCompName
                    DisplayString,
                chCompVersion
                    DisplayString,
                chCompTimeStamp
                    TimeTicks,
                chCompAccessPolicy
                    INTEGER,
                chCompBasicCommStr
                    OCTET STRING,
                chCompROCommStr
                    OCTET STRING,
                chCompRWCommStr
                    OCTET STRING,
                chCompSUCommStr
                    OCTET STRING,
                chCompNetAdr
                    NetworkAddress
            }

        chCompID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "An unique value identifying a component, which includes,
                 but is not limited to, routers, bridges, and terminal
                 servers.  Multiple instances of a functional device may
                 exist within the same chassis."
            ::= { chCompEntry 1 }

        chCompAdminStatus OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        invalid(2),
                        enabled(3),
                        testing(4),
                        operational(5),
                        error(6),
                        disabled(7),
                        delete(8)
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "Provides the state of the given component.  A component
                 is activated by writing a value of enabled(3).  Once
                 enabled, a component enters testing mode, which is
                 denoted by testing(4), when this object is read.  After
                 tests are complete, the component either enters the
                 operational(5), or the error(6) state.

                 The component may be de-activated by writing a value of
                 disabled(7).  In a disabled state, a component does
                 exist within the given chassis, but is benign.  A disabled
                 component is available for subsequent activation."
            ::= { chCompEntry 2 }

        chCompArg OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE(32))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "A variable that may be passed to a component, when it
                 is being either enabled or disabled."
            ::= { chCompEntry 3 }

        chCompType  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Identifies a component within this chassis.  A vendor's
                 authoritative identification of this component type.
                 By convention, this value is allocated within the SMI
                 enterprises subtree(1.3.6.1.4.1), and provides an easy
                 and unambiguous means for determining the component
                 type.  If this information is not present or unknown,
                 its value should be set to the OBJECT IDENTIFIER { 0 0 },
                 which is a syntactically valid object identifier."
            ::= { chCompEntry 4 }

        chCompName  OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..32))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "A textual description of the component."
            ::= { chCompEntry 5 }

        chCompVersion  OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..32))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "A textual description of the version/revision level for
                 this component's software."
            ::= { chCompEntry 6 }

        chCompTimeStamp  OBJECT-TYPE
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The value of sysUpTime of this management entity, when
                 this component was last (re-)initialized."
            ::= { chCompEntry 7 }

        chCompAccessPolicy  OBJECT-TYPE
            SYNTAX  INTEGER {
                        unknown(1),             --  none of the following
                        invalid(2),
                        same(3),                --  current IP address and
                                                --  community string pair
                                                --  may be used to access
                                                --  this component
                        otherCommStr(4),        --  use community string
                                                --  specified by
                                                --  chCompROCommStr (or
                                                --  chCompRWCommStr), with
                                                --  current IP address to
                                                --  access this component.
                                                --  Community access profile
                                                --  and view are determined
                                                --  by the associated
                                                --  community string that
                                                --  will be used.
                        other(5)                --  use community string
                                                --  specified by
                                                --  chCompROCommStr (or
                                                --  chCompRWCommStr), and
                                                --  address specified by
                                                --  chCompNetAdr to access
                                                --  this component.
                                                --  Community access profile
                                                --  and view are determined
                                                --  by the associated
                                                --  community string that
                                                --  will be used.
                }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "Defines access information for the pertinent component."
            ::= { chCompEntry 8 }

        chCompBasicCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Read-only community string for the pertinent component.
                 If the value of chCompAccessPolicy is otherCommStr(4) or
                 other(5), then this object shall determine the read-only
                 Community String to be used when accessing this component.
                 This also defined the basic read only community string to
                 access MIBs registered to this component."
            ::= { chCompEntry 9 }

        chCompROCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Read-only community string for the pertinent component.
                 If the value of chCompAccessPolicy is otherCommStr(4) or
                 other(5), then this object shall determine the read-only
                 Community String to be used when accessing this component.
                 This also defined the read only community string to
                 access MIBs registered to this component."
            ::= { chCompEntry 10 }

        chCompRWCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Read-write community string for the pertinent component.
                 If the value of chCompAccessPolicy is otherCommStr(4) or
                 other(5), then this object shall determine the read-write
                 Community String to be used when accessing this component.
                 This also defined the read write community string to
                 access MIBs registered to this component."
            ::= { chCompEntry 11 }

        chCompSUCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Super user community string for the pertinent component.
                 If the value of chCompAccessPolicy is otherCommStr(4) or
                 other(5), then this object shall determine the read-write
                 Community String to be used when accessing this component.
                 This also defined the read write community string to
                 access MIBs registered to this component."
            ::= { chCompEntry 12 }

        chCompNetAdr  OBJECT-TYPE
            SYNTAX  NetworkAddress
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "If the value of chCompAccessPolicy is other(5), then this
                 object shall determine the Network Address to be used to
                 access this component. In all other cases, a value of
                 0.0.0.0 shall be returned, when read."
            ::= { chCompEntry 13 }

        --  Slot Table and definitions
        --  A module is the physical entity that resides in a chassis slot.
        --  A module is also denoted as a board or card.  A component may
        --  be realized by one or more modules, or one or more components
        --  may be realized by the same module.
        --  The slot table provides a physical representation of a chassis
        --  and its components.

        chSlotTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of modules installed in this chassis.  A component,
                 such as a router, may be incorporated on one or more
                 modules.  More than one component may be incorporated on
                 each module."
            ::= { chassis 5 }

        chSlotEntry  OBJECT-TYPE
            SYNTAX  ChSlotEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A slot entry containing objects for a particular
                 module."
            INDEX  { chSlotID, chSlotCompID }
            ::= { chSlotTable 1 }

        ChSlotEntry  ::=
            SEQUENCE {
                chSlotID
                    INTEGER,
                chSlotCompID
                    INTEGER,
                chSlotClass
                    OBJECT IDENTIFIER,
                chSlotModuleType
                    OBJECT IDENTIFIER,
                chSlotModuleName
                    DisplayString,
                chSlotModuleVersion
                    DisplayString,
                chSlotModuleTimeStamp
                    TimeTicks
            }

        chSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The slot number containing this module.  An unique
                 value, in the range between 0 and and the value of
                 chNumSlots."
            ::= { chSlotEntry 1 }

        chSlotCompID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The ID value for the component incorporated within this
                 module.  This object is similar to chCompID."
            ::= { chSlotEntry 2 }

        chSlotClass  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The class (or type) of slot.  For example, slots that
                only allow for power supply modules fall into a class
                that is different from slots that allow only interface
                cards."
            ::= { chSlotEntry 3 }
        chSlotModuleType  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Uniquely defines the module type.  A vendor's
                 authoritative identification for a module.  By
                 convention, this value is allocated within the SMI
                 enterprises subtree(1.3.6.1.4.1), and provides an easy
                 and unambiguous means for determining the type of
                 module."
            ::= { chSlotEntry 4 }

        chSlotModuleName  OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..32))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "A textual description of the module."
            ::= { chSlotEntry 5 }

        chSlotModuleVersion  OBJECT-TYPE
            SYNTAX  DisplayString (SIZE (0..32))
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "A textual description of the version/revision level for
                 this module's hardware and firmware."
            ::= { chSlotEntry 6 }

        chSlotModuleTimeStamp  OBJECT-TYPE
            SYNTAX  TimeTicks
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "The value of sysUpTime for this management entity, when
                 this module was last (re-)initialized."
            ::= { chSlotEntry 7 }



        --  MIB Table
        --  This table provides a list of MIBs that are incorporated in
        --  the various components within chassis slots.

        chCompMIBTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF ChCompMIBEntry
            ACCESS  not-accessible
            STATUS  deprecated
            DESCRIPTION
                "A list of MIBs incorporated on components and their
                 respective modules, within this chassis."
            ::= { chassis 6 }

        chCompMIBEntry  OBJECT-TYPE
            SYNTAX  ChCompMIBEntry
            ACCESS  not-accessible
            STATUS  deprecated
            DESCRIPTION
                "A MIB entry containing objects for a MIB that is
                 realized by a particular module."
            INDEX { chCompMIBID, chCompMIBSlotID, chCompMIBCompID }
            ::= { chCompMIBTable 1 }

        ChCompMIBEntry ::=
            SEQUENCE {
                chCompMIBID
                    INTEGER,
                chCompMIBSlotID
                    INTEGER,
                chCompMIBCompID
                    INTEGER,
                chCompMIBGrpOID
                    OBJECT IDENTIFIER,
                chCompMIBVectorObjectBase
                    OBJECT IDENTIFIER,
                chCompMIBVectorNum
                    INTEGER,
                chCompMIBType
                    INTEGER,
                chCompMIBStatus
                    INTEGER
            }

        chCompMIBID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  deprecated
            DESCRIPTION
                "An unique value identifying an instance of a MIB."
        ::= { chCompMIBEntry 1 }

        chCompMIBSlotID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  deprecated
            DESCRIPTION
                "The slot number for the module that incorporates this
                 MIB.  The value shall be in the range between 0 and
                 chNumSlots.  A non-zero values indicates that the
                 information presented by this entry is realized only
                 on the module in the specified slot.  A zero value
                 indicates that this information pertains to the entire
                 component, without partitioning across modules.

                 This object is similar to chSlotID."
        ::= { chCompMIBEntry 2 }

        chCompMIBCompID  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  deprecated
            DESCRIPTION
                "The component related to this MIB.  This object is
                 similar to chCompID."
            ::= { chCompMIBEntry 3 }

        chCompMIBGrpOID  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-write
            STATUS  deprecated
            DESCRIPTION
                "A reference to a specific MIB group definition.  For
                 example, in the case of MIB-II, the value of this
                 object may refer to an applicable group, which has
                 been implemented.

                 The access is read-write.  This will allow network
                 administrators, to register MIBs for a module that is
                 known to the chassis management entity, by type alone:
                 that is, a module for which component information is
                 unknown."
            ::= { chCompMIBEntry 4 }

        chCompMIBVectorObjectBase  OBJECT-TYPE
            SYNTAX  OBJECT IDENTIFIER
            ACCESS  read-write
            STATUS  deprecated
            DESCRIPTION
                "A reference to a specific entry of a vector object
                 within this MIB, associated with the module identified
                 by chCompMIBSlotID.  For example, in the case of a
                 repeater, the value of this object may refer to an
                 entry in prtrBasicPortTable.  This object facilitates
                 logical to physical mapping of entities such as
                 channels, links, interfaces, and ports."
            ::= { chCompMIBEntry 5 }

        chCompMIBVectorNum  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-write
            STATUS  deprecated
            DESCRIPTION
                "A value indicating the number of entries, starting with
                 the one denoted by chCompMIBVectorObjectBase, that are
                 realized on this module."
            ::= { chCompMIBEntry 6 }

        chCompMIBType  OBJECT-TYPE
            SYNTAX  INTEGER {
                not-instanced(1),
                instanced(2)
            }
            ACCESS  read-write
            STATUS  deprecated
            DESCRIPTION
                "Depicts whether the MIB in question is instanced
                or not.

                For reason similar to ones that apply to
                chCompMIBGrpOID, the access mode is read-write."
            ::= { chCompMIBEntry 7 }

        chCompMIBStatus  OBJECT-TYPE
            SYNTAX  INTEGER {
                unknown(1),
                invalid(2),
                agent(3),
                management(4)
            }
            ACCESS  read-only
            STATUS  deprecated
            DESCRIPTION
                "Depicts the status of the MIB.  If marked as agent
                 the MIB is generated based upon the components
                 defined.  If marked as management the entry was entered
                 via a management station.  If marked invalid the
                 entry is to be deleted."
            ::= { chCompMIBEntry 8 }

        chPhysicalChanges  OBJECT-TYPE
            SYNTAX   Counter
            ACCESS   read-only
            STATUS   deprecated
            DESCRIPTION
                "Depicts the number of physical changes that have occured
                 to the chassis MIB.  This includes additions and
                 removal of components in the component table."
            ::= { chassis 7 }

        chLogicalChanges  OBJECT-TYPE
            SYNTAX   Counter
            ACCESS   read-only
            STATUS   deprecated
            DESCRIPTION
                "Depicts the number of logical changes that have occured
                 to the chassis MIB.  This includes all sets to name
                 strings etc."
            ::= { chassis 8 }

        chCompGlobalBasicCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE(1..27))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This is defined as the base read only community string to
                 access MIBs on this module. A write to this object will 
                 change all instances of chCompBasicCommStr."
            ::= { chassis 9 }

        chCompGlobalROCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE(1..27))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This is defined as the expanded read only community string to
                 access MIBs on this module. A write to this object will 
                 change all instances of chCompROCommStr."
            ::= { chassis 10 }

        chCompGlobalRWCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE(1..27))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This is defined as the read write community string to
                 access MIBs on this module.  A write to this object will 
                 change all instances of chCompRWCommStr."
            ::= { chassis 11 }

        chCompGlobalSUCommStr  OBJECT-TYPE
            SYNTAX  OCTET STRING (SIZE(1..27))
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "This is defined as the super user community string to
                 access MIBs on this module.  A write to this object will 
                 change all instances of chCompSUCommStr."
            ::= { chassis 12 }