The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CT-HSIMPHYS-MIB.


Vendor: Enterasys Networks Inc
Mib: CT-HSIMPHYS-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
CT-HSIMPHYS-MIB DEFINITIONS ::= BEGIN

   --  ct-hsimphys-mib.txt
   --  Revision: 01.00.00
   --  Part Number:
   --  Date: July 21, 1998

   --  Cabletron Systems, Inc.
   --  35 Industrial Way, P.O. Box 5005
   --  Rochester, NH 03867-0505
   --  (603) 332-9400
   --  support@ctron.com

   --  This module provides an enterprise-specific HSIM container MIB.
   --
   --  This module will be extended, as needed.
   --

   --  Cabletron Systems reserves the right to make changes in
   --  specification and other information contained in this document
   --  without prior notice.  The reader should consult Cabletron Systems
   --  to determine whether any such changes have been made.
   --
   --  In no event shall Cabletron Systems be liable for any incidental,
   --  indirect, special, or consequential damages whatsoever (including
   --  but not limited to lost profits) arising out of or related to this
   --  document or the information contained in it, even if Cabletron
   --  Systems has been advised of, known, or should have known, the
   --  possibility of such damages.
   --
   --  Cabletron grants vendors, end-users, and other interested parties
   --  a non-exclusive license to use this Specification in connection
   --  with the management of Cabletron products.

   --  Copyright March 98 Cabletron Systems

   --  This MIB is intended to provide a central repository & link to all
   --  information about the physical aspect of an HSIM.  Physical info
   --  includes items related to the HW inventory , BOOT, EPLD, and other
   --  low level information.  For the purposes of this MIB, no difference
   --  is recognized between a permantly-installed "option card", such as
   --  the onboard WAN interface on the HSIM-W65/75, and an actual WPIM.

   IMPORTS
      OBJECT-TYPE
         FROM RFC-1212
      DisplayString
         FROM RFC1213-MIB
      ctHSIMPhysMib
         FROM CTRON-MIB-NAMES;


   --================= HSIM Info ===================

   hsimInfo  OBJECT IDENTIFIER ::= { ctHSIMPhysMib 1 }

   hsimBoardRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the printed circuit board
         revision level."
      ::= { hsimInfo 1 }

   hsimBoardId  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the printed circuit board
         idenitifer."
      ::= { hsimInfo 2 }

   hsimEpldRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the programmable
         logic device revision level."
      ::= { hsimInfo 3 }

   hsimEpldId  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the programmable
         logic device identifier."
      ::= { hsimInfo 4 }

   hsimFsbRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the first stage
         boot revision level."
      ::= { hsimInfo 5 }

   hsimSsbRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the second stage
         boot revision level."
      ::= { hsimInfo 6 }

   hsimFwRev  OBJECT-TYPE
         SYNTAX  DisplayString
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is the HSIM firmware
         revision level."
      ::= { hsimInfo 7 }

   --=================== HSIM Peripheral MBus Info =====================

   hsimPeripheralMBusInfo OBJECT IDENTIFIER
      ::= { hsimInfo 8 }

   mBusNumberBoardsInstalled  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is number of MBus boards
         installed in this unit."
      ::= { hsimPeripheralMBusInfo 1 }

   mBusBoardTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF MBusBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of MBus boards present in this unit"
      ::= { hsimPeripheralMBusInfo 2 }

   mBusBoardEntry  OBJECT-TYPE
         SYNTAX  MBusBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an MBus board that is
         present in this unit"
         INDEX   { mBusBoardID }
      ::= { mBusBoardTable 1 }

   MBusBoardEntry  ::=
         SEQUENCE {
                  mBusBoardID          INTEGER,
                  mBusBoardEntryType   INTEGER,
                  mBusBoardOIDPointer  OBJECT IDENTIFIER
                  }

   mBusBoardID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies the physical MBus board within the system."
      ::= { mBusBoardEntry 1 }

   mBusBoardEntryType OBJECT-TYPE
         SYNTAX  INTEGER   {
                           unknown(1),
                           cmm(2)
                           }

         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of MBus
         board installed."
      ::= { mBusBoardEntry 2 }

   mBusBoardOIDPointer OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object defines the start of a MIB that
         can be used to determine more specific information about
         the given MBus board."
      ::= { mBusBoardEntry 3 }


   --=================== HSIM Peripheral WPIM Info =====================

   hsimPeripheralWpimInfo OBJECT IDENTIFIER
      ::= { hsimInfo 9 }

   wpimNumberBoardsInstalled  OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is number of WPIM boards
         installed in this unit."
      ::= { hsimPeripheralWpimInfo 1 }

   wpimBoardTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF WpimBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of WPIM boards present in this unit"
      ::= { hsimPeripheralWpimInfo 2 }

   wpimBoardEntry  OBJECT-TYPE
         SYNTAX  WpimBoardEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is a WPIM board that is
         present in this unit"
         INDEX   { wpimBoardID }
      ::= { wpimBoardTable 1 }

   WpimBoardEntry  ::=
         SEQUENCE {
                  wpimBoardID          INTEGER,
                  wpimBoardEntryType   OBJECT IDENTIFIER,
                  wpimBoardOIDPointer  OBJECT IDENTIFIER
                  }

   wpimBoardID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies this WPIM board."
      ::= { wpimBoardEntry 1 }

   wpimBoardEntryType OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of WPIM
         board installed.  This is within the portWpim branch
         of the namingTree (1.3.6.1.4.1.52.3.8.1.2.5)"
      ::= { wpimBoardEntry 2 }

   wpimBoardOIDPointer OBJECT-TYPE
         SYNTAX  OBJECT IDENTIFIER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object defines the start of a MIB that
         can be used to determine more specific information about
         the given WPIM board."
      ::= { wpimBoardEntry 3 }

   --=================== HSIM Local HW Devices Info =====================

   hsimLocalHwDevicesInfo OBJECT IDENTIFIER
      ::= { hsimInfo 10 }

   localHwDevicesTable  OBJECT-TYPE
         SYNTAX  SEQUENCE OF LocalHwDevicesEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "A list of specific hardware devices present in this unit"
      ::= { hsimLocalHwDevicesInfo 1 }

   localHwDevicesEntry  OBJECT-TYPE
         SYNTAX  LocalHwDevicesEntry
         ACCESS  not-accessible
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is a WPIM module that is
         present in this unit"
         INDEX   { localHwDeviceID }
      ::= { localHwDevicesTable 1 }

   LocalHwDevicesEntry  ::=
         SEQUENCE {
                  localHwDeviceID            INTEGER,
                  localHwDeviceType          INTEGER,
                  localHwDeviceOperStatus    INTEGER,
                  localHwDeviceAdminStatus   INTEGER
                  }

   localHwDeviceID OBJECT-TYPE
         SYNTAX  INTEGER
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object is an index that uniquely
         identifies the assoicated local hardware device."
      ::= { localHwDevicesEntry 1 }

   localHwDeviceType OBJECT-TYPE
         SYNTAX  INTEGER {
                         unknown(1),
                         siemensMunich32(2),
                         mitelMT8985(3)
                         }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "The value of this object identifies the type of local
         hardware device.  These local hardware devices are those
         specific ICs unique to this HSIM such as Siemens
         Munich32, or Mitel MT8985."
      ::= { localHwDevicesEntry 2 }

   localHwDeviceOperStatus OBJECT-TYPE
         SYNTAX  INTEGER {
                   up(1),       -- ready to pass packets
                   down(2),
                   testing(3),  -- in some test mode
                   unknown(4),  -- status can not be determined
                                -- for some reason.
                   dormant(5)
               }
         ACCESS  read-only
         STATUS  mandatory
         DESCRIPTION
        "This object describes the current state of the device."
      ::= { localHwDevicesEntry 3 }

   localHwDeviceAdminStatus OBJECT-TYPE
         SYNTAX  INTEGER {
                   up(1),       -- ready execute
                   down(2),
                   testing(3)   -- in some test mode
               }
         ACCESS  read-write
         STATUS  mandatory
         DESCRIPTION
        "This object is used by the Network Management System to
         request a change in the current state of the device."
      ::= { localHwDevicesEntry 4 }