AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Enterasys-Networks-Inc » CTRON-ENVIRONMENT-MIB » Objects

CTRON-ENVIRONMENT-MIB.mib object view, vendor Enterasys-Networks-Inc

Introduction

Most network devices and programs ship with so-called MIB files to describe the parameters and meanings (i.e.: friendly names) which are available for monitoring via SNMP.
ActiveXperts Network Monitor 2024 can import vendor-specific MIB files, so it can be used to monitor specific OID's (Object Identifiers). This way, you can monitor your devices, computers, etc. by selecting your relevant OID's by name.

ActiveXperts Network Monitor 2024 can import MIB file CTRON-ENVIRONMENT-MIB and use it to monitor vendor specific OID's.

CTRON-ENVIRONMENT-MIB file content

Object view of CTRON-ENVIRONMENT-MIB:

Scalar Object
chEnvAmbientTemp .1.3.6.1.4.1.52.4.1.1.8.1.1
The ambient temperature of the room in which the chassis is located. If this sensor is broken or not supported, then this object will be set to zero. The value of this object is the actual temperature in degrees Fahrenheit * 10.
chEnvAmbientStatus .1.3.6.1.4.1.52.4.1.1.8.1.2
This object reflects the status of the ambient temperature reading.
chEnvHumidity .1.3.6.1.4.1.52.4.1.1.8.1.3
The humidity value of the air flowing thru the chassis. The value of this object is the actual humidity * 10.
chEnvHumidityStatus .1.3.6.1.4.1.52.4.1.1.8.1.4
This object reflects the status of the ambient humidity reading.
chEnvAmbientHot .1.3.6.1.4.1.52.4.1.1.8.1.5
The temperature value above which the ambient temperature is deemed to be hot.
chEnvAmbientWarm .1.3.6.1.4.1.52.4.1.1.8.1.6
The temperature value above which the ambient temperature is deemed to be warm, if it is below or equal the hot value.
chEnvAmbientCool .1.3.6.1.4.1.52.4.1.1.8.1.7
The temperature value below which the ambient temperature is deemed to be cool, if it is above or equal the cold value.
chEnvAmbientCold .1.3.6.1.4.1.52.4.1.1.8.1.8
The temperature value below which the ambient temperature is deemed to be cold.
chEnvHumidityMoist .1.3.6.1.4.1.52.4.1.1.8.1.9
The humidity value above which the chassis humidity is deemed to be moist.
chEnvHumidityDry .1.3.6.1.4.1.52.4.1.1.8.1.10
The humidity value below which the chassis humidity is deemed to be a static risk.
chEnvNumFans .1.3.6.1.4.1.52.4.1.1.8.1.11
Number of fans in a chassis.
chEnvFanEntry .1.3.6.1.4.1.52.4.1.1.8.1.12.1
A slot entry containing objects for a particular module.
boardEnvSlotEntry .1.3.6.1.4.1.52.4.1.1.8.2.1.1
A slot entry containing objects for a particular module.
psEnvSlotEntry .1.3.6.1.4.1.52.4.1.1.8.3.1.1
A slot entry containing objects for a particular module.
Tabular Object
chEnvFanID .1.3.6.1.4.1.52.4.1.1.8.1.12.1.1
A unique value, in the range between 1 and and the value of chEnvNumFans.
chEnvFanStatus .1.3.6.1.4.1.52.4.1.1.8.1.12.1.2
This object reflects the status of the chassis fan.
chEnvFanAdmin .1.3.6.1.4.1.52.4.1.1.8.1.12.1.3
This object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3 (testing) then value will return to it's previous value prior to being set at 3.
chEnvFanSpeed .1.3.6.1.4.1.52.4.1.1.8.1.12.1.4
The fan speed expressed as a percentage of the maximum fan speed.
boardEnvSlotID .1.3.6.1.4.1.52.4.1.1.8.2.1.1.1
The slot number of a chassis slot in which this board is installed. This object is similiar to chSlotID in the Chassis MIB.
boardEnvTemp .1.3.6.1.4.1.52.4.1.1.8.2.1.1.2
The temperature of the networking board. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenheit * 10.
boardEnvTempStatus .1.3.6.1.4.1.52.4.1.1.8.2.1.1.3
This object reflects the status of the board temperature reading.
boardEnvTempRelStatus .1.3.6.1.4.1.52.4.1.1.8.2.1.1.4
This object reflects the status of the board temperature reading relative to the ambient temperature.
boardEnvShutdownAdmin .1.3.6.1.4.1.52.4.1.1.8.2.1.1.5
This object enables or disables the auto shutdown due to a temperature condition.
boardEnvTempHot .1.3.6.1.4.1.52.4.1.1.8.2.1.1.6
The temperature value above which the board temperature is deemed to be hot.
boardEnvTempWarm .1.3.6.1.4.1.52.4.1.1.8.2.1.1.7
The temperature value above which the board temperature is deemed to be warm, if it is below or equal the hot value.
boardEnvTempCool .1.3.6.1.4.1.52.4.1.1.8.2.1.1.8
The temperature value below which the board temperature is deemed to be cool, if it is above or equal the cold value.
boardEnvTempCold .1.3.6.1.4.1.52.4.1.1.8.2.1.1.9
The temperature value below which the board temperature is deemed to be cold.
boardEnvTempRelHot .1.3.6.1.4.1.52.4.1.1.8.2.1.1.10
The temperature value above ambient at which the board temperature is deemed to be hot relative to ambient.
boardEnvTempRelWarm .1.3.6.1.4.1.52.4.1.1.8.2.1.1.11
The temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvTempRelHot.
boardEnvTempMaxFanRelHot .1.3.6.1.4.1.52.4.1.1.8.2.1.1.12
The temperature value above ambient at which the board temperature is deemed to be hot relative to ambient, with all fans in the chassis running at there maximum speed.
boardEnvTempMaxFanRelWarm .1.3.6.1.4.1.52.4.1.1.8.2.1.1.13
The temperature value above ambient at which the board temperature is deemed to be warm relative to ambient, if it is below the relative hot value of boardEnvTempMaxFanRelHot, with all fans in the chassis running at there maximum speed.
psEnvSlotID .1.3.6.1.4.1.52.4.1.1.8.3.1.1.1
The slot number of a chassis slot in which this power supply is installed. An unique value, in the range between 1 and and the value of chNumSlots. This object is similiar to chSlotID in the Chassis MIB.
psEnvTemp .1.3.6.1.4.1.52.4.1.1.8.3.1.1.2
The temperature of the power supply. If this sensor is broken or not supported, then this object will be set to zero. The temperature is in degrees Fahrenheit * 10.
psEnvTempStatus .1.3.6.1.4.1.52.4.1.1.8.3.1.1.3
This object reflects the status of the power supply temperature reading.
psEnvTempHot .1.3.6.1.4.1.52.4.1.1.8.3.1.1.4
The temperature value above which the power supply temperature is deemed to be hot.
psEnvTempWarm .1.3.6.1.4.1.52.4.1.1.8.3.1.1.5
The temperature value above which the power supply temperature is deemed to be warm, if it is below or equal the hot value.
psEnvTempCool .1.3.6.1.4.1.52.4.1.1.8.3.1.1.6
The temperature value below which the power supply temperature is deemed to be cool, if it is above or equal the cold value.
psEnvTempCold .1.3.6.1.4.1.52.4.1.1.8.3.1.1.7
The temperature value below which the power supply temperature is deemed to be cold.
psEnvFanStatus .1.3.6.1.4.1.52.4.1.1.8.3.1.1.8
This object reflects the status of the chassis fan.
psEnvFanAdmin .1.3.6.1.4.1.52.4.1.1.8.3.1.1.9
This object is used to select the operational mode of the fan. If the value is set to 1 (auto) then fan speed is based on temperature. If the value is set to 3 (testing) then value will return to it's previous value prior to being set at 3.
psEnvFanSpeed .1.3.6.1.4.1.52.4.1.1.8.3.1.1.10
The fan speed expressed as a percentage of the maximum fan speed.
Table
chEnvFanTable .1.3.6.1.4.1.52.4.1.1.8.1.12
A list of fans installed in this chassis.
boardEnvSlotTable .1.3.6.1.4.1.52.4.1.1.8.2.1
A list of networking modules installed in this chassis.
psEnvSlotTable .1.3.6.1.4.1.52.4.1.1.8.3.1
A list of networking modules installed in this chassis.
Object Identifier
chEnv .1.3.6.1.4.1.52.4.1.1.8.1
boardEnv .1.3.6.1.4.1.52.4.1.1.8.2
psEnv .1.3.6.1.4.1.52.4.1.1.8.3
bbuEnv .1.3.6.1.4.1.52.4.1.1.8.4