ActiveXperts Network Monitor 2019##AdminFavorites

CTRON-FDDI-FNB-MIB by vendor Enterasys Networks Inc

CTRON-FDDI-FNB-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CTRON-FDDI-FNB-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-FDDI-FNB-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
CTRON-FDDI-FNB-MIB DEFINITIONS ::= BEGIN

        --  CTRON-FDDI-FNB-mib.txt The FDDI FNB backplane control MIB
        --  Revision: 1.01.00
        --  Date: September 13, 1995 

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific connection MIB.
        --
        --  This module will be extended, as needed.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright August 95 Cabletron Systems

        IMPORTS
                Counter
                        FROM RFC1155-SMI
                ctFDDIFnb
                        FROM CTRON-MIB-NAMES
                DisplayString
                        FROM RFC1213-MIB
                OBJECT-TYPE
                        FROM RFC-1212;

        --  DisplayString ::= OCTET STRING


--  This MIB module uses the extended OBJECT-TYPE macro as defined
--  RFC 1212


        --======    group definitions     ===========

        ctFDDIResource  OBJECT IDENTIFIER ::= { ctFDDIFnb 1 }
        ctFDDINonMux    OBJECT IDENTIFIER ::= { ctFDDIFnb 2 }
        ctFDDIMux       OBJECT IDENTIFIER ::= { ctFDDIFnb 3 }
        ctFDDISerialConfig      OBJECT IDENTIFIER ::= { ctFDDIFnb 4 }

        --=====    ctFDDIResource group       ========
        
        
        ctFDDIResourceTable     OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIResourceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table specifies the physical resources
                associated with the FNB and general FNB operation for a 
                particular module in a particular slot."
        ::= { ctFDDIResource 1 }

        ctFDDIResourceEntry     OBJECT-TYPE
            SYNTAX      CtFDDIResourceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific physical resource entry"
            INDEX { ctFDDIResourceSlotID, ctFDDIResourceID }
        ::= { ctFDDIResourceTable 1 }

        CtFDDIResourceEntry     ::= SEQUENCE {
                ctFDDIResourceSlotID
                        INTEGER,
                ctFDDIResourceID
                        INTEGER,
                ctFDDIResourceType
                        OBJECT IDENTIFIER,
                ctFDDIResourceNumbInstance
                        INTEGER
                }

        ctFDDIResourceSlotID    OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of a slot as defined by chSlotID
                as defined in the chassis MIB."
        ::= { ctFDDIResourceEntry 1 }

        ctFDDIResourceID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A unique index that defines a specific physcial resource for
                which this relationship exists.  The value of this is as
                defined by chResourceID in the chassis MIB."
        ::= { ctFDDIResourceEntry 2 }

        ctFDDIResourceType      OBJECT-TYPE
            SYNTAX      OBJECT IDENTIFIER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the type of resource.  This is the same value as
                chResourceType in the chassis MIB."
            ::= { ctFDDIResourceEntry 3 }

        ctFDDIResourceNumbInstance      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines the number of instances of a physical
                resource.

                Specific resource instances are physically located from 
                top-to-bottom on a particular module. If there are multiple 
                'columns' of a resource from the top to the bottom, then 
                the numbering will start from the left side and proceed 
                top-to-bottom in each column.

                For instance, the first FNB ring will be instance 1 (top 
                in the chassis) while the second FNB ring is instance 2 
                (below FNB 1 in the backplane)."
        ::= { ctFDDIResourceEntry 4 }

--      The ctFDDINonMuxGroup
--      This group pertains to all devices that provide FDDI conectivity
--      which are not multiplexed.

        ctFDDINonMuxCapTable    OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes all possible capabilities/configurations
                for all non-muxed FDDI configurations within the chassis."
        ::= { ctFDDINonMux 1 }

        ctFDDINonMuxCapEntry    OBJECT-TYPE
            SYNTAX      CtFDDINonMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a particular capability/configuration entry."
            INDEX { ctFDDINMSlot, ctFDDINMConfigID }
            ::= { ctFDDINonMuxCapTable 1 }

        CtFDDINonMuxCapEntry    ::= SEQUENCE {
                ctFDDINMSlot
                        INTEGER,
                ctFDDINMConfigID
                        INTEGER,
                ctFDDINMConfig
                        DisplayString,
                ctFDDINMConfigDesc
                        DisplayString
                }

        ctFDDINMSlot    OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The slot within the chassis for which this 
                configuration information is defined."
            ::= { ctFDDINonMuxCapEntry 1 }

        ctFDDINMConfigID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The instance of a particular configuration."
            ::= { ctFDDINonMuxCapEntry 2 }

        ctFDDINMConfig  OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines a specific valid connection
                configuration.  It will specify the connection state of all 
                resource instances.  If an instance of a resource is
                not specified, then it is disconnected.

                Each valid configuration is encoded in an ascii string, using 
                a specified format for interpretation.  The connection 
                specifications are in groups of four where each group defines 
                a specific connection configuration.  The terms of a connection
                group is defined as follows:

                        1st - The resource ID as defined by 
                        ctFDDIResourceID.

                        2nd - A specific instance of the physical 
                        resource.  This will be a value between 1 and 
                        ctFDDIResourceNumbInstance for the particular 
                        resource ID in the first term.  If a resource ID
                        has more than one specific resource instance, but
                        the whole resource can be connected, then this 
                        term will have the value '0' to signify all instances 
                        of the resource.

                        3rd - The connection ID for this specific 
                        physical resource.  This value is the same as 
                        ctFDDINMConnectionID, and through the 
                        ctFDDINonMuxConnectionTable maps to a specific
                        instance of SMT and MAC.

                For example if the value of this object is '1.1.2.2.1.1',
                then it states that resource 1, instance 1 is connected to 
                connection ID 2 and resource 2, instance 1 is connected to 
                connection ID 1 and is inserted into its FDDI ring.

                If a valid configuration is no connections then this 
                object will have a value of '0.0.0'"
            ::= { ctFDDINonMuxCapEntry 3 }

        ctFDDINMConfigDesc      OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object contains a textual description of a valid 
                connection configuration.  This is a more user-friendly 
                representation of the configuration than the ctFDDINMConfig
                object."
            ::= { ctFDDINonMuxCapEntry 4 } 


        ctFDDINonMuxCapEnableTable      OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the currently enabled configuration
                for each module."
            ::= { ctFDDINonMux 2 }

        ctFDDINonMuxCapEnableEntry      OBJECT-TYPE
            SYNTAX      CtFDDINonMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific configuration enable entry."
            INDEX { ctFDDINMEnableSlot }
            ::= { ctFDDINonMuxCapEnableTable 1 }

        CtFDDINonMuxCapEnableEntry ::= SEQUENCE {
                ctFDDINMEnableSlot
                        INTEGER,
                ctFDDINMCapEnable
                        INTEGER
                }

        ctFDDINMEnableSlot      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this configuration enable
                pertains."
            ::= { ctFDDINonMuxCapEnableEntry 1 }

        ctFDDINMCapEnable       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "A specific configuration that is enabled.  

                Enabling a configuration is done by writing the value of 
                ctFDDINMConfigID for a specific configuration to this object.

                This object, when read, will return the value of 
                ctFDDINMConfigID for the presently enabled configuration."
            ::= { ctFDDINonMuxCapEnableEntry 2 }


        ctFDDINonMuxConnectionTable     OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxConnectionEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table defines specific information for each defined
                FDDI/FNB connection.  This maps the third sub identifier 
                of ctFDDINMConfig to a particular SMT and MAC instance in
                the 1512 FDDI MIB."
            ::= { ctFDDINonMux 3 }

        ctFDDINonMuxConnectionEntry     OBJECT-TYPE
            SYNTAX      CtFDDINonMuxConnectionEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific configuration connection entry."
            INDEX { ctFDDINMConnectionSlot, ctFDDINMConnectionID }
            ::= { ctFDDINonMuxConnectionTable 1 }

        CtFDDINonMuxConnectionEntry ::= SEQUENCE {
                ctFDDINMConnectionSlot
                        INTEGER,
                ctFDDINMConnectionID
                        INTEGER,
                ctFDDINMSMT
                        INTEGER,
                ctFDDINMMAC
                        INTEGER,
                ctFDDINMBytes
                        INTEGER,
                ctFDDINMFrames
                        INTEGER
                }

        ctFDDINMConnectionSlot  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this connection entry is
                defined."
            ::= { ctFDDINonMuxConnectionEntry 1 }

        ctFDDINMConnectionID    OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific connection identifier.  Valid
                connection identifiers are defined by the third
                sub-identifier in ctFDDINMConfig as identified by
                ctFDDINMCapEnable."
            ::= { ctFDDINonMuxConnectionEntry 2 }

        ctFDDINMSMT             OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of SMT for which this entry pertains."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
            ::= { ctFDDINonMuxConnectionEntry 3 }

        ctFDDINMMAC             OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific MAC that this connection entry pertains."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
            ::= { ctFDDINonMuxConnectionEntry 4 }

        ctFDDINMBytes   OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in bytes per second."
        ::= { ctFDDINonMuxConnectionEntry 5 }

        ctFDDINMFrames  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in frames per second."
        ::= { ctFDDINonMuxConnectionEntry 6 }


        
        ctFDDINonMuxInterfaceTable      OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDINonMuxInterfaceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describs the number of interfaces defined by
                each non multiplexing FDDI FNB module."
            ::= { ctFDDINonMux 4 }

        ctFDDINonMuxInterfaceEntry      OBJECT-TYPE
            SYNTAX      CtFDDINonMuxInterfaceEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "A specfic non multiplexing module interface definition."
            INDEX { ctFDDINMInterSlot }
            ::= { ctFDDINonMuxInterfaceTable 1 }

        CtFDDINonMuxInterfaceEntry ::= SEQUENCE {
                ctFDDINMInterSlot
                        INTEGER,
                ctFDDINMNumbInterfaces
                        INTEGER
        }

        ctFDDINMInterSlot       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this inteface entry is
                defined."
            ::= { ctFDDINonMuxInterfaceEntry 1 }

        ctFDDINMNumbInterfaces  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The number of interfaces defined on this particular
                module."
        ::= { ctFDDINonMuxInterfaceEntry 2 }


--      the ctFDDIMuxGroup
--      This groups controls those devices that perform a FDDI multiplexing
--      operation

        ctFDDIMuxCapTable       OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes all possible configuration/capabilities
                defined for a FDDI multiplexing module."
            ::= { ctFDDIMux 1 }

        ctFDDIMuxCapEntry       OBJECT-TYPE
            SYNTAX      CtFDDIMuxCapEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specfic FDDI multiplexor capability/configuration
                entry."
            INDEX { ctFDDIMuxSlot, ctFDDIMuxConfig }
            ::= { ctFDDIMuxCapTable 1 }

        CtFDDIMuxCapEntry       ::= SEQUENCE {
                ctFDDIMuxSlot
                        INTEGER,
                ctFDDIMuxConfigID
                        INTEGER,
                ctFDDIMuxConfig
                        DisplayString,
                ctFDDIMuxConfigDesc
                        DisplayString
                }

        ctFDDIMuxSlot   OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot within the chassis for which this
                multiplexed capability/configuration entry pertains."
            ::= { ctFDDIMuxCapEntry 1 }

        ctFDDIMuxConfigID       OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The instance of a particular configuration."
            ::= { ctFDDIMuxCapEntry 2 }

        ctFDDIMuxConfig OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object defines a specific valid connection
                configuration.  It will specify the connection state of all
                resource instances.  If an instance of a resource is
                not specified, then it is disconnected.

                Each valid configuration is encoded in an ascii string, using
                a specified format for interpretation.  The specific 
                connections are in groups of four where each group defines a 
                specific connection configuration.  The terms of the connection 
                group are defined as follows:

                        1st - Resource ID.  The value is the same as 
                        ctFDDIResourceID for a specific resource entry.

                        2nd - Instance of the resource.  This has a value in
                        the range of 1 to ctFDDIResourceNumbInstance.

                        3rd - Path of the resource as input to the
                        multiplexor.  Paths are specified as 1
                        for the primary ring and 2 for the secondary.

                        4th - This is the multiplexor output channel 
                        that this resource comes out of the multiplexor.
                        This value is the same as a value of ctFDDIMuxOutID.

                        5th - Ring Connectivity.  This sub-identifier
                        describes if the given mux-in resource 
                        (sub-identifiers 1-3) is inserted into the backplane
                        FNB ring.  Valid values are 0 for no 1 for yes.

                So for example a value of 1.1.1.1.0.2.2.2.2.1 is resource 1,
                instance 1 (primary) is on mux-out 1 and it's not inserted;
                resource 2, instance 2 (secondary) is on mux-out 2 and
                is inserted into the backplane.

                If a valid configuration is no connections then this
                object will have a value of '0.0.0.0.0'"
            ::= { ctFDDIMuxCapEntry 3 }

        ctFDDIMuxConfigDesc      OBJECT-TYPE
            SYNTAX      DisplayString
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "This object contains a textual description of a valid 
                connection configuration.  This is a more user-friendly
                representation of the configuration than the ctFDDIMuxConfig
                object."
            ::= { ctFDDIMuxCapEntry 4 }


        ctFDDIMuxCapEnableTable OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the currently enabled configuration
                for each module."
            ::= { ctFDDIMux 2 }

        ctFDDIMuxCapEnableEntry OBJECT-TYPE
            SYNTAX      CtFDDIMuxCapEnableEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a specific configuration enable entry."
            INDEX { ctFDDIMuxEnableSlot }
            ::= { ctFDDIMuxCapEnableTable 1 }

        CtFDDIMuxCapEnableEntry ::= SEQUENCE {
                ctFDDIMuxEnableSlot
                        INTEGER,
                ctFDDIMuxCapEnable
                        INTEGER,
                ctFDDIMuxMasterPortAssignmentChange
                        Counter
                }

        ctFDDIMuxEnableSlot     OBJECT-TYPE
            SYNTAX      INTEGER (1..256)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific slot for which this configuration enable
                pertains."
            ::= { ctFDDIMuxCapEnableEntry 1 }

        ctFDDIMuxCapEnable      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of the configuration that is
                enabled.

                Setting this object with a specific value of ctFDDIMuxConfigID
                enabled that configuration.  A request of the value of this
                object will return the value of ctFDDIMuxConfigID for the
                presently enabled configuration."
            ::= { ctFDDIMuxCapEnableEntry 2 }

        ctFDDIMuxMasterPortAssignmentChange OBJECT-TYPE
           SYNTAX       Counter
           ACCESS       read-only
           STATUS       mandatory
           DESCRIPTION
                "Depicts the number of changes to the master port to multiplexor
                output mapping."
        ::= { ctFDDIMuxCapEnableEntry 3 }

        ctFDDIMuxOutTable       OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIMuxOutEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes the multiplexor outputs for each of the
                FNB multiplexor modules.  This maps the multiplexor output
                to a specific instance of MAC and SMT in the FDDI MIB."
            ::= { ctFDDIMux 3 }

        ctFDDIMuxOutEntry       OBJECT-TYPE
            SYNTAX      CtFDDIMuxOutEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a particular multiplexor output."
            INDEX { ctFDDIMuxOutSlot, ctFDDIMuxOutID }
            ::= { ctFDDIMuxOutTable 1 }

        CtFDDIMuxOutEntry       ::= SEQUENCE {
                ctFDDIMuxOutSlot
                        INTEGER,
                ctFDDIMuxOutID
                        INTEGER,
                ctFDDIMuxOutMACIndex
                        INTEGER,
                ctFDDIMuxOutSMTIndex
                        INTEGER,
                ctFDDIMuxBytes
                        INTEGER,
                ctFDDIMuxFrames
                        INTEGER
                }

        ctFDDIMuxOutSlot        OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The given slot for which this multiplexor output information
                pertains."
            ::= { ctFDDIMuxOutEntry 1 }

        ctFDDIMuxOutID  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The specific instance of the multiplexor output.  Instances
                of this object are used by the values of ctFDDIMuxConfig."
            ::= { ctFDDIMuxOutEntry 2 }

        ctFDDIMuxOutMACIndex    OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The MAC instance of this multiplexor output.  If this
                this object has a value greater than 0, then this 
                value is the same as fddimibMACIndex.  If this object has the 
                value of 0, the given mux-out does not have a MAC."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
            ::= { ctFDDIMuxOutEntry 3 }

        ctFDDIMuxOutSMTIndex    OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Identifies the instance of SMT as defined within the
                FDDI MIB."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
            ::= { ctFDDIMuxOutEntry 4 }

        ctFDDIMuxBytes  OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in bytes per second."
        ::= { ctFDDIMuxOutEntry 5 }

        ctFDDIMuxFrames OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "The bandwidth utilization in frames per second."
        ::= { ctFDDIMuxOutEntry 6 }



        ctFDDIMuxMasterPortTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF CtFDDIMuxMasterPortEntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "A list of entries that define master ports as they are
                defined for the given multiplexed FDDI connection."
            ::= { ctFDDIMux 4 }

        ctFDDIMuxMasterPortEntry        OBJECT-TYPE
            SYNTAX CtFDDIMuxMasterPortEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "A specific FDDI-FNB multiplexed master port definition."
            INDEX { ctFDDIMuxMasterPortSlotID, ctFDDIMuxMasterPortID }
        ::= { ctFDDIMuxMasterPortTable 1 }

        CtFDDIMuxMasterPortEntry        ::= SEQUENCE {
                ctFDDIMuxMasterPortSlotID
                        INTEGER,
                ctFDDIMuxMasterPortID
                        INTEGER,
                ctFDDIMuxMasterPortAssignment
                        INTEGER,
                ctFDDIMuxMasterPortIndex
                        INTEGER
                }

        ctFDDIMuxMasterPortSlotID       OBJECT-TYPE
            SYNTAX      INTEGER (1..255)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A specific instance of a slot as defined by chSlotID."
        ::= { ctFDDIMuxMasterPortEntry 1 }

        ctFDDIMuxMasterPortID   OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "A unique identifier for this specific master port."
        ::= { ctFDDIMuxMasterPortEntry 2 }

        ctFDDIMuxMasterPortAssignment   OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "Provides the masterport to multiplexor output mapping.
                This is as defined by ctFDDIMuxOutMacAssignment."
        ::= { ctFDDIMuxMasterPortEntry 3 }

        ctFDDIMuxMasterPortIndex        OBJECT-TYPE
            SYNTAX      INTEGER (1..65535)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines a specific port within the FDDI MIBs fddimibPORTTable."
            REFERENCE
                "The IETF RFC FDDI-SMT73-MIB, fddimibPORTIndex"
            ::= { ctFDDIMuxMasterPortEntry 4 }

--      The ctFDDISerialControl group
--      This group describes the control over the FDDI serial controlled
--      modules. 

        ctFDDINumbModules       OBJECT-TYPE
            SYNTAX      INTEGER (0..14)
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the number of modules that are present configurable
                thru the serial control portion of this MIB.

                This directly reflects the number of rows found within the
                ctFDDISerialConfigTable."
            ::= { ctFDDISerialConfig 1 }

        ctFDDISerialConfigTable OBJECT-TYPE
           SYNTAX       SEQUENCE OF CtFDDISerialConfigEntry
           ACCESS       not-accessible
           STATUS       mandatory
           DESCRIPTION
                "This table describes the adminstrative control over each
                of the FNB serial control modules."
            ::= { ctFDDISerialConfig 2 }

        ctFDDISerialConfigEntry OBJECT-TYPE
            SYNTAX      CtFDDISerialConfigEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes the controls over a single FNB serial control
                entry."
            INDEX { ctFDDISerialSlotID }
            ::= { ctFDDISerialConfigTable 1 }

        CtFDDISerialConfigEntry ::= SEQUENCE {
                ctFDDISerialSlotID
                        INTEGER,
                ctFDDISerialAdminStatus
                        INTEGER,
                ctFDDISerialOperStatus
                        INTEGER
                }

        ctFDDISerialSlotID      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot that this FNB serial control module is in.
                 This is an instance of chSlotID as defined in the chassis MIB."
           ::= { ctFDDISerialConfigEntry 1 }

        ctFDDISerialAdminStatus OBJECT-TYPE
            SYNTAX      INTEGER {
                insertFNB1(1),
                insertFNB2(2),
                insertFNB1FNB2(3),
                bypass(4),
                hwControlFNB1(5),
                hwControlFNB2(6),
                hwControl(7)            -- Use hardware control
                }
            ACCESS      read-write
            STATUS      mandatory
            DESCRIPTION
                "Describes the adminstrative desired state for this FNB
                serial control module.
        
                        insertFNB1(1) - The serial controlled module should be
                        inserted into FNB-1 and bypass FNB-2.

                        insertFNB2(2) - The serial contolled module should be
                        inserted into FNB-2 and bypass FNB-1.

                        insertFNB1FNB2(3) - Insert the serial controlled module
                        on both FNBs.

                        bypass(4) - Bypass the connection to both FNBs.

                        hwControlFNB1(5) - Use hardware settings for FNB-1.

                        hwControlFNB2(6) - Use hardware settings for FNB-2.

                        hwControl(7) - Use the hardware settings for both
                        FNBs."
            ::= { ctFDDISerialConfigEntry 2 }

        ctFDDISerialOperStatus  OBJECT-TYPE
            SYNTAX      INTEGER {
                insertFNB1(1),
                insertFNB2(2),
                insertFNB1FNB2(3),
                bypass(4)
                }
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the operational status of this FDDI serial
                controlled module.

                        insertFNB1(1) - The serial controlled module is
                        inserted into FNB-1 and bypassed from FNB-2.

                        insertFNB2(2) - The serial controlled module is
                        bypassed from FNB-1 and inserted into FNB-2.

                        insertFNB1FNB2(3) - The serial controlled module is
                        inserted into both FNB-1 and FNB-2.

                        bypass(4) - The serial controlled module is bypassed
                        from both FNB-1 and FNB-2."
            ::= { ctFDDISerialConfigEntry 3 }


        ctFDDIModuleFPIMTable   OBJECT-TYPE
            SYNTAX      SEQUENCE OF CtFDDIModuleFPIMEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "This table describes the FPIMs that are on the front panel of
                each FDDI serial control module, if that module supports FPIMs."
            ::= { ctFDDISerialConfig 3 }

        ctFDDIModuleFPIMEntry   OBJECT-TYPE
            SYNTAX      CtFDDIModuleFPIMEntry
            ACCESS      not-accessible
            STATUS      mandatory
            DESCRIPTION
                "Describes a single FDDI FPIM on a module."
            INDEX { ctFddiFPIMSlotID, ctFddiFPIM }
            ::= { ctFDDIModuleFPIMTable 1 }

        CtFDDIModuleFPIMEntry ::= SEQUENCE {
                ctFddiFPIMSlotID
                        INTEGER,
                ctFddiFPIM
                        INTEGER,
                ctFddiFPIMStatus
                        INTEGER,
                ctFddiFPIMType
                        OBJECT IDENTIFIER
                }

        ctFddiFPIMSlotID        OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the slot in which this module exists.  This
                is an instance of chSlotID as found in the chassis MIB."
            ::= { ctFDDIModuleFPIMEntry 1 }

        ctFddiFPIM      OBJECT-TYPE
            SYNTAX      INTEGER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Defines the instance of the port for which this definition
                is made.  Ports are physically located from top-to-bottom on a 
                particular module. If there are multiple 'columns' of ports
                from the top to the bottom, then the numbering will start 
                from the left side and proceed top-to-bottom in each column."
            ::= { ctFDDIModuleFPIMEntry 2 }

        ctFddiFPIMStatus        OBJECT-TYPE
            SYNTAX      INTEGER {
                        link(1),
                        noLink(2),
                        notSupported(3)
                }
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the link status of the given FPIM.

                A value of link(1) states that a link is present.

                A value of noLink(2) states that no link is present.

                A value of notSupported(3) means that link status is not 
                supported by this port and is unknown."
            ::= { ctFDDIModuleFPIMEntry 4 }

        ctFddiFPIMType  OBJECT-TYPE
            SYNTAX      OBJECT IDENTIFIER
            ACCESS      read-only
            STATUS      mandatory
            DESCRIPTION
                "Describes the type of FPIM as found in ctron-oids."
            ::= { ctFDDIModuleFPIMEntry 5 }

END