ActiveXperts Network Monitor 2019##AdminFavorites

CTRON-FNBTR-MIB by vendor Enterasys Networks Inc

CTRON-FNBTR-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CTRON-FNBTR-MIB.


Vendor: Enterasys Networks Inc
Mib: CTRON-FNBTR-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
CTRON-FNBTR-MIB DEFINITIONS ::= BEGIN

        --  ctfnbtr-mib.txt
        --  Revision: 1.06.00
        --  Part Number:  2170557-01
        --  Date: August 14, 1994

        --  Cabletron Systems, Inc.
        --  35 Industrial Way, P.O. Box 5005
        --  Rochester, NH 03867-0505
        --  (603) 332-9400
        --  support@ctron.com

        --  This module provides authoritative definitions for Cabletron's
        --  enterprise-specific FNB Token Ring MIB.
        --
        --  This module will be extended, as required.
        --

        --  Cabletron Systems reserves the right to make changes in 
        --  specification and other information contained in this document 
        --  without prior notice.  The reader should consult Cabletron Systems
        --  to determine whether any such changes have been made.
        --
        --  In no event shall Cabletron Systems be liable for any incidental, 
        --  indirect, special, or consequential damages whatsoever (including 
        --  but not limited to lost profits) arising out of or related to this
        --  document or the information contained in it, even if Cabletron
        --  Systems has been advised of, known, or should have known, the 
        --  possibility of such damages.
        --
        --  Cabletron grants vendors, end-users, and other interested parties
        --  a non-exclusive license to use this Specification in connection
        --  with the management of Cabletron products.

        --  Copyright (c)October, 1995 Cabletron Systems, Inc.

        IMPORTS
                ctTokenRingFnb                  FROM CTRON-MIB-NAMES
                OBJECT-TYPE                     FROM RFC-1212;

        ctronFnbTR      OBJECT IDENTIFIER ::= { ctTokenRingFnb 1 }
        ctronMultiFnbTR OBJECT IDENTIFIER ::= { ctTokenRingFnb 2 }

        -- ==========================================================
        --
        --  The fnbTR group
        --
        --  This group of objects is used to control and report status
        --  of Token Ring devices supporting only 1 FNB ring.
        --
        --  Implementation of this group is mandatory for Token Ring
        --  subsystems on devices that incorporate the FNB.
        --
        -- ==========================================================

        ctronFnbTRTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF CtronFnbTREntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                    "A list of entries that provide connection status of
                    Token Ring subsystems, for the FNB."
            ::= { ctronFnbTR 1 }

        ctronFnbTREntry  OBJECT-TYPE
            SYNTAX  CtronFnbTREntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                    "An entry in the ctronFnbTRTable containing objects that
                    provide FNB connection status for a Token Ring sub-
                    system."
            INDEX  { ctronFnbTRIndex }
            ::= { ctronFnbTRTable 1 }


        CtronFnbTREntry ::=
            SEQUENCE {
                ctronFnbTRIndex
                    INTEGER,
                ctronFnbConnectLeft
                    INTEGER,
                ctronFnbConnectRight
                    INTEGER,
                ctronFnbBypass
                    INTEGER,
                ctronFnbRPBypass
                    INTEGER
            }

        ctronFnbTRIndex  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                    "An unique value for each Token Ring subsystem.  Its
                     value ranges between 1 and 'chNumSlots' defined in 
                     chassis-mib.txt."
            ::= { ctronFnbTREntry 1 }

        ctronFnbConnectLeft  OBJECT-TYPE
            SYNTAX  INTEGER {
                        other(1),       --  none of the following
                        detached(2),
                        attached(3),
                        faulted(4)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                    "Denotes the connection status of the Token Ring
                     board to the left of the current one.  An attempt to
                     set a value of 1 or 4 will result in an error code
                     of badValue."
            ::= { ctronFnbTREntry 2 }

        ctronFnbConnectRight  OBJECT-TYPE
            SYNTAX  INTEGER {
                        other(1),       --  none of the following
                        detached(2),
                        attached(3),
                        faulted(4)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                    "Denotes the connection status of the Token Ring
                    board to the right of the current one.  An attempt
                    to set a value of 1 or 4 will result in an error
                    code of badValue."
            ::= { ctronFnbTREntry 3 }

        ctronFnbBypass  OBJECT-TYPE
            SYNTAX  INTEGER {
                        other(1),       --  none of the following
                        disabled(2),
                        enabled(3)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                    "Denotes the bypass status of the current Token Ring
                    board."
            ::= { ctronFnbTREntry 4 }
        
        ctronFnbRPBypass  OBJECT-TYPE
        SYNTAX  INTEGER {
                other(1),
                enable(2),
                disabled(3)
        }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "Denotes the Ring Port bypass status of the current Token Ring
            board.  If this capability is not available on this board, the
            value 'other' is returned when read, and BADSETINFO when written."
        ::= { ctronFnbTREntry 5 }

        -- ==========================================================
        --
        --  The multiFnbTR group
        --
        --  This group of objects is used to control and report status
        --  of Token Ring devices supporting multiple FNB rings.
        --
        --  Implementation of this group is mandatory for Token Ring
        --  subsystems on devices that manage devices supporting multiple
        --  FNB rings.
        --
        -- ==========================================================

        ctronMultiFnbTRTable  OBJECT-TYPE
            SYNTAX  SEQUENCE OF CtronMultiFnbTREntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                    "A list of entries that provide connection status of
                    Token Ring subsystems, for the FNB."
            ::= { ctronMultiFnbTR 1 }

        ctronMultiFnbTREntry  OBJECT-TYPE
            SYNTAX  CtronMultiFnbTREntry
            ACCESS  not-accessible
            STATUS  mandatory
            DESCRIPTION
                "An entry in the ctronMultiFnbTRTable containing objects that
                provide FNB connection status for a Token Ring sub-
                system."
            INDEX  { ctronMultiFnbTRIndex, ctronMultiFnbRingIndex }
            ::= { ctronMultiFnbTRTable 1 }


        CtronMultiFnbTREntry ::=
            SEQUENCE {
                ctronMultiFnbTRIndex
                    INTEGER,
                ctronMultiFnbRingIndex
                    INTEGER,
                ctronMultiFnbConnectLeft
                    INTEGER,
                ctronMultiFnbConnectRight
                    INTEGER,
                ctronMultiFnbBypass
                    INTEGER,
                ctronMultiFnbRPBypass
                    INTEGER
            }

        ctronMultiFnbTRIndex  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "An unique value for each Token Ring subsystem.  Its
                value ranges between 1 and 'chNumSlots' defined in 
                chassis-mib.txt."
            ::= { ctronMultiFnbTREntry 1 }

        ctronMultiFnbRingIndex  OBJECT-TYPE
            SYNTAX  INTEGER
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "An unique value representing an instance of an FNB ring path 
                attachment.  Its value ranges between 1 and n, where n equals 
                the maximum number of FNB ring paths available in a given 
                chassis.  For an MMAC chassis with an FNB, this number is 4."
            ::= { ctronMultiFnbTREntry 2 }

        ctronMultiFnbConnectLeft  OBJECT-TYPE
            SYNTAX  INTEGER {
                    other(1),       --  none of the following
                    detached(2),
                    attached(3),
                    faulted(4)
                    }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Denotes the connection status of the left attach circuitry for
                a particular FNB ring path attachment on this Token Ring 
                oard."
            ::= { ctronMultiFnbTREntry 3 }

        ctronMultiFnbConnectRight  OBJECT-TYPE
            SYNTAX  INTEGER {
                    other(1),       --  none of the following
                    detached(2),
                    attached(3),
                    faulted(4)
                    }
            ACCESS  read-only
            STATUS  mandatory
            DESCRIPTION
                "Denotes the connection status of the right attach circuitry for
                a particular FNB ring path attachment on this Token Ring board."
            ::= { ctronMultiFnbTREntry 4 }

        ctronMultiFnbBypass  OBJECT-TYPE
            SYNTAX  INTEGER {
                    other(1),       --  none of the following
                    disabled(2),
                    enabled(3)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "Denotes the connection status of the bypass circuitry for a 
                particular backplane ring path attachment on this Token Ring 
                board."
            ::= { ctronMultiFnbTREntry 5 }

        ctronMultiFnbRPBypass  OBJECT-TYPE
            SYNTAX  INTEGER {
                    other(1),
                    enable(2),
                    disabled(3)
                    }
            ACCESS  read-write
            STATUS  mandatory
            DESCRIPTION
                "Denotes the connection status of the ring port bypass 
                circuitry for a particular backplane ring path attachment on
                his Token Ring board.  If this capability is not available on
                this board, the value 'other' is returned when read, and
                BADSETINFO when written."
            ::= { ctronMultiFnbTREntry 6 }

--
-- Revision History:
--
-- Revision: 1.04.01
-- Date:     March 17, 1994
--
-- a) Added ctronMultiFnbTR branch at { ctTokenRingFnb 2 } in support of port switched
--    Token Ring MIMs.
-- b) Made the access policy for the objects ctronMultiFnbConnectLeft and 
--    ctronMultiFnbConnectRight read-only.
-- c) Modified the copyright date.
--

END