AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | IoT | IT Service | Network/System | Infra | Performance | Protocol | SaaS | Security | Service Level | Storage | Linux | VMware | VoIP | Web | Wireless | SNMP

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » RFC » ROHC-MIB

ROHC-MIB device MIB details by RFC

ROHC-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing ROHC-MIB.


Vendor: RFC
Mib: ROHC-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- WinAgents MIB Extraction Wizard
-- Extracted from rfc3816.txt 17.03.2005 16:20:13

ROHC-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE,
    Unsigned32, Counter32, mib-2
        FROM SNMPv2-SMI                                -- [RFC2578]

    TEXTUAL-CONVENTION, TruthValue,
    TimeInterval, DateAndTime
        FROM SNMPv2-TC                                 -- [RFC2579]

    MODULE-COMPLIANCE, OBJECT-GROUP
        FROM SNMPv2-CONF                               -- [RFC2580]

    SnmpAdminString
        FROM SNMP-FRAMEWORK-MIB                        -- [RFC3411]

    ifIndex
        FROM IF-MIB;                                   -- [RFC2863]

rohcMIB MODULE-IDENTITY
    LAST-UPDATED "200406030000Z"  -- June 3, 2004
    ORGANIZATION "IETF Robust Header Compression Working Group"
    CONTACT-INFO
       "WG charter:
          http://www.ietf.org/html.charters/rohc-charter.html

        Mailing Lists:
          General Discussion: rohc@ietf.org
          To Subscribe: rohc-request@ietf.org
          In Body: subscribe your_email_address

        Editor:
          Juergen Quittek
          NEC Europe Ltd.
          Network Laboratories
          Kurfuersten-Anlage 36

          69221 Heidelberg
          Germany
          Tel: +49 6221 90511-15
          EMail: quittek@netlab.nec.de"
    DESCRIPTION
        "This MIB module defines a set of basic objects for
         monitoring and configuring robust header compression.
         The module covers information about running instances
         of ROHC (compressors or decompressors) at IP interfaces.

         Information about compressor contexts and decompressor
         contexts has different structure for different profiles.
         Therefore it is not provided by this MIB module, but by
         individual modules for different profiles.

         Copyright (C) The Internet Society (2004). The
         initial version of this MIB module was published
         in RFC 3816. For full legal notices see the RFC
         itself or see:
         http://www.ietf.org/copyrights/ianamib.html"

    REVISION    "200406030000Z"  -- June 3, 2004
    DESCRIPTION "Initial version, published as RFC 3816."
    ::= { mib-2 112 }

RohcChannelIdentifier ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "A number identifying a channel.
         The value of 0 must not be used as identifier
         of an existing channel."
    SYNTAX       Unsigned32 (1..4294967295)

RohcChannelIdentifierOrZero ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "A number identifying a channel.
         The value of 0 is indicates that
         no channel is identified."
    SYNTAX       Unsigned32 (0..4294967295)

RohcCompressionRatio ::= TEXTUAL-CONVENTION
    DISPLAY-HINT "d"
    STATUS       current
    DESCRIPTION
        "A number indicating a compression ratio over

         a set of bytes.  The value is defined as
         1000 * bytes(compressed) / bytes(original)
         rounded to the next integer value.

         Note that compressed sets of bytes can be larger
         than the corresponding uncompressed ones.
         Therefore, the number can be greater than 1000."
    SYNTAX       Unsigned32

--
-- The groups defined within this MIB module:
--

rohcObjects       OBJECT IDENTIFIER ::= { rohcMIB 1 }
rohcConformance   OBJECT IDENTIFIER ::= { rohcMIB 2 }

--
-- The ROHC Instance group lists properties of ROHC
-- instances in the rohcInstanceTable, about the channels used
-- by the instances in the rohcChanneltable and about the profiles
-- available at the instances in the rohcProfileTable.
--

rohcInstanceObjects       OBJECT IDENTIFIER ::= { rohcObjects 1 }

--
-- Channel Table
--
-- Listing all channels used for ROHC data channel
-- and/or as feedback channel.
--

rohcChannelTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RohcChannelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists and describes all ROHC channels
         per interface."
    ::= { rohcInstanceObjects 1 }

rohcChannelEntry OBJECT-TYPE
    SYNTAX      RohcChannelEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry describing a particular script.  Every script that
         is stored in non-volatile memory is required to appear in

         this script table.

         Note, that the rohcChannelID identifies the channel
         uniquely.  The ifIndex is part of the index of this table
         just in order to allow addressing channels per interface."
    INDEX { ifIndex, rohcChannelID }
    ::= { rohcChannelTable 1 }

RohcChannelEntry ::= SEQUENCE {
    rohcChannelID               RohcChannelIdentifier,
    rohcChannelType             INTEGER,
    rohcChannelFeedbackFor      RohcChannelIdentifierOrZero,
    rohcChannelDescr            SnmpAdminString,
    rohcChannelStatus           INTEGER
}

rohcChannelID OBJECT-TYPE
    SYNTAX      RohcChannelIdentifier
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The locally arbitrary, but unique identifier associated
         with this channel.  The value is REQUIRED to be unique
         per ROHC MIB implementation independent of the associated
         interface.

         The value is REQUIRED to remain constant at least from one
         re-initialization of the entity's network management system
         to the next re-initialization.  It is RECOMMENDED that the
         value persist across such re-initializations."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcChannelEntry 2 }

rohcChannelType OBJECT-TYPE
    SYNTAX      INTEGER {
                    notInUse(1),
                    rohc(2),
                    dedicatedFeedback(3)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Type of usage of the channel.  A channel might be currently
         not in use for ROHC or feedback, it might be in use as
         a ROHC channel carrying packets and optional piggy-backed
         feedback, or it might be used as a dedicated feedback
         channel exclusively carrying feedback."

    ::= { rohcChannelEntry 3 }

rohcChannelFeedbackFor OBJECT-TYPE
    SYNTAX      RohcChannelIdentifierOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The index of another channel of this interface for which
         the channel serves as feedback channel.

         If no feedback information is transferred on this channel,
         then the value of this ID is 0.  If the channel type is set
         to notInUse(1), then the value of this object must be 0.
         If the channel type is rohc(2) and the value of this object
         is a valid channel ID, then feedback information is
         piggy-backed on the ROHC channel.  If the channel type is
         dedicatedFeedback(3), then feedback is transferred on this
         channel and the value of this object MUST be different from
         0 and MUST identify an existing ROHC channel."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcChannelEntry 4 }

rohcChannelDescr OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A textual description of the channel."
    ::= { rohcChannelEntry 5 }

rohcChannelStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    enabled(1),
                    disabled(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the channel."
    ::= { rohcChannelEntry 6 }

--
-- Instances of ROHC
--
-- This table lists properties of running instances of ROHC
-- compressors and decompressors at the managed node.
--


rohcInstanceTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RohcInstanceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists properties of running instances
         of robust header compressors and decompressors
         at IP interfaces.  It is indexed by interface number,
         the type of instance (compressor or decompressor),
         and the ID of the channel used by the instance as
         ROHC channel.

         Note that the rohcChannelID uniquely identifies an
         instance.  The ifIndex and rohcInstanceType are part
         of the index, because it simplifies accessing instances
         per interface and for addressing either compressors or
         decompressors only."
    ::= { rohcInstanceObjects 2 }

rohcInstanceEntry OBJECT-TYPE
    SYNTAX      RohcInstanceEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry describing a particular instance
         of a robust header compressor or decompressor."
    INDEX { ifIndex, rohcInstanceType, rohcChannelID }
    ::= { rohcInstanceTable 1 }

RohcInstanceEntry ::= SEQUENCE {
    rohcInstanceType               INTEGER,
    rohcInstanceFBChannelID        RohcChannelIdentifierOrZero,
    rohcInstanceVendor             OBJECT IDENTIFIER,
    rohcInstanceVersion            SnmpAdminString,
    rohcInstanceDescr              SnmpAdminString,
    rohcInstanceClockRes           Unsigned32,
    rohcInstanceMaxCID             Unsigned32,
    rohcInstanceLargeCIDs          TruthValue,
    rohcInstanceMRRU               Unsigned32,
    rohcInstanceContextStorageTime TimeInterval,
    rohcInstanceStatus             INTEGER,
    rohcInstanceContextsTotal      Counter32,
    rohcInstanceContextsCurrent    Unsigned32,
    rohcInstancePackets            Counter32,
    rohcInstanceIRs                Counter32,
    rohcInstanceIRDYNs             Counter32,
    rohcInstanceFeedbacks          Counter32,

    rohcInstanceCompressionRatio   RohcCompressionRatio
}

rohcInstanceType OBJECT-TYPE
    SYNTAX      INTEGER {
                    compressor(1),
                    decompressor(2)
                }
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Type of the instance of ROHC. It is either a
         compressor instance or a decompressor instance."
    ::= { rohcInstanceEntry 2 }

rohcInstanceFBChannelID OBJECT-TYPE
    SYNTAX      RohcChannelIdentifierOrZero
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Identifier of the channel used for feedback.
         If no feedback channel is used, the value of
         this object is 0 ."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcInstanceEntry 4 }

rohcInstanceVendor OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An object identifier that identifies the vendor who
         provides the implementation of robust header description.
         This object identifier SHALL point to the object identifier
         directly below the enterprise object identifier
         {1 3 6 1 4 1} allocated for the vendor.  The value must be
         the object identifier {0 0} if the vendor is not known."
    ::= { rohcInstanceEntry 5 }

rohcInstanceVersion OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The version number of the implementation of robust header
         compression.  The zero-length string shall be used if the
         implementation does not have a version number.


         It is suggested that the version number consist of one or
         more decimal numbers separated by dots, where the first
         number is called the major version number."
    ::= { rohcInstanceEntry 6 }

rohcInstanceDescr OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A textual description of the implementation."
    ::= { rohcInstanceEntry 7 }

rohcInstanceClockRes OBJECT-TYPE
    SYNTAX      Unsigned32
    UNITS       "milliseconds"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the system clock resolution in
         units of milliseconds.  A zero (0) value means that there
         is no clock available."
    ::= { rohcInstanceEntry 8 }

rohcInstanceMaxCID OBJECT-TYPE
    SYNTAX      Unsigned32 (1..16383)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The highest context ID number to be used by the
         compressor.  Note that this parameter is not coupled to,
         but in effect further constrained by,
         rohcChannelLargeCIDs."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcInstanceEntry 9 }

rohcInstanceLargeCIDs OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "When retrieved, this boolean object returns false if
         the short CID representation (0 bytes or 1 prefix byte,
         covering CID 0 to 15) is used; it returns true, if the
         embedded CID representation (1 or 2 embedded CID bytes
         covering CID 0 to 16383) is used."

    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcInstanceEntry 10 }

rohcInstanceMRRU OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Maximum reconstructed reception unit.  This is the
         size of the largest reconstructed unit in octets that
         the decompressor is expected to reassemble from
         segments (see RFC 3095, Section 5.2.5).  Note that this
         size includes the CRC.  If MRRU is negotiated to be 0,
         no segment headers are allowed on the channel."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcInstanceEntry 11 }

rohcInstanceContextStorageTime OBJECT-TYPE
    SYNTAX      TimeInterval
    UNITS       "centi-seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "This object indicates the default maximum amount of time
         information on a context belonging to this instance is kept
         as entry in the rohcContextTable after the context is
         expired or terminated.  The value of this object is used
         to initialize rohcContexStorageTime object when a new
         context is created.
         Changing the value of an rohcInstanceContextStorageTime
         instance does not affect any entry of the rohcContextTable
         created previously.
         ROHC-MIB implementations SHOULD store the set value of this
         object persistently."
    DEFVAL { 360000 }
    ::= { rohcInstanceEntry 12 }

rohcInstanceStatus OBJECT-TYPE
    SYNTAX      INTEGER {
                    enabled(1),
                    disabled(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Status of the instance of ROHC."

    ::= { rohcInstanceEntry 13 }

rohcInstanceContextsTotal OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Counter of all contexts created by this instance.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime."
    ::= { rohcInstanceEntry 14 }

rohcInstanceContextsCurrent OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Number of currently active contexts created by this
         instance."
    ::= { rohcInstanceEntry 15 }

rohcInstancePackets OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Counter of all packets passing this instance.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime."
    ::= { rohcInstanceEntry 16 }

rohcInstanceIRs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all IR packets that are either sent
         or received by this instance.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the

         value of ifCounterDiscontinuityTime."
    REFERENCE
        "RFC 3095, Section 5.7.7.1"
    ::= { rohcInstanceEntry 17 }

rohcInstanceIRDYNs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all IR-DYN packets that are either sent
         or received by this instance.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime."
    REFERENCE
        "RFC 3095, Section 5.7.7.2"
    ::= { rohcInstanceEntry 18 }

rohcInstanceFeedbacks OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all feedbacks that are either sent
         or received by this instance.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime."
    ::= { rohcInstanceEntry 19 }

rohcInstanceCompressionRatio OBJECT-TYPE
    SYNTAX      RohcCompressionRatio
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the compression ratio so far over all
         packets on the channel served by this instance.  The
         compression is computed over all bytes of the IP packets
         including the IP header but excluding all lower layer
         headers."
    ::= { rohcInstanceEntry 20 }

--

-- Profile Table
--

rohcProfileTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RohcProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists a set of profiles supported by the
         instance."
    REFERENCE
        "RFC 3095, Section 5.1.1"
    ::= { rohcInstanceObjects 3 }

rohcProfileEntry OBJECT-TYPE
    SYNTAX      RohcProfileEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry describing a particular profile supported by
         the instance.  It is indexed by the rohcChannelID
         identifying the instance and by the rohcProfile."
    INDEX { rohcChannelID, rohcProfile }
    ::= { rohcProfileTable 1 }

RohcProfileEntry ::= SEQUENCE {
    rohcProfile            Unsigned32,
    rohcProfileVendor      OBJECT IDENTIFIER,
    rohcProfileVersion     SnmpAdminString,
    rohcProfileDescr       SnmpAdminString,
    rohcProfileNegotiated  TruthValue
}

rohcProfile OBJECT-TYPE
    SYNTAX      Unsigned32 (0..65535)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Identifier of a profile supported.  For a listing of
         possible profile values, see the IANA registry for
         'RObust Header Compression (ROHC) Profile Identifiers'
         at http://www.iana.org/assignments/rohc-pro-ids"
    ::= { rohcProfileEntry 2 }

rohcProfileVendor OBJECT-TYPE
    SYNTAX      OBJECT IDENTIFIER
    MAX-ACCESS  read-only
    STATUS      current

    DESCRIPTION
        "An object identifier that identifies the vendor who
         provides the implementation of robust header description.
         This object identifier SHALL point to the object identifier
         directly below the enterprise object identifier
         {1 3 6 1 4 1} allocated for the vendor.  The value must be
         the object identifier {0 0} if the vendor is not known."
    ::= { rohcProfileEntry 3 }

rohcProfileVersion OBJECT-TYPE
    SYNTAX      SnmpAdminString (SIZE (0..32))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The version number of the implementation of robust header
         compression.  The zero-length string shall be used if the
         implementation does not have a version number.

         It is suggested that the version number consist of one or
         more decimal numbers separated by dots, where the first
         number is called the major version number."
    ::= { rohcProfileEntry 4 }

rohcProfileDescr OBJECT-TYPE
    SYNTAX      SnmpAdminString
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "A textual description of the implementation."
    ::= { rohcProfileEntry 5 }

rohcProfileNegotiated OBJECT-TYPE
    SYNTAX      TruthValue
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "When retrieved, this boolean object returns true
         if the profile has been negotiated to be used at
         the instance, i.e., is supported also be the
         corresponding compressor/decompressor."
    ::= { rohcProfileEntry 6 }

--
-- Context Table
--

rohcContextTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF RohcContextEntry

    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "This table lists and describes all compressor contexts
         per instance."
    ::= { rohcObjects 2 }

rohcContextEntry OBJECT-TYPE
    SYNTAX      RohcContextEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "An entry describing a particular compressor context."
    INDEX {
        rohcChannelID,
        rohcContextCID
    }
    ::= { rohcContextTable 1 }

RohcContextEntry ::= SEQUENCE {
    rohcContextCID                  Unsigned32,
    rohcContextCIDState             INTEGER,
    rohcContextProfile              Unsigned32,
    rohcContextDecompressorDepth    Unsigned32,
    rohcContextStorageTime          TimeInterval,
    rohcContextActivationTime       DateAndTime,
    rohcContextDeactivationTime     DateAndTime,
    rohcContextPackets              Counter32,
    rohcContextIRs                  Counter32,
    rohcContextIRDYNs               Counter32,
    rohcContextFeedbacks            Counter32,
    rohcContextDecompressorFailures Counter32,
    rohcContextDecompressorRepairs  Counter32,
    rohcContextAllPacketsRatio      RohcCompressionRatio,
    rohcContextAllHeadersRatio      RohcCompressionRatio,
    rohcContextAllPacketsMeanSize   Unsigned32,
    rohcContextAllHeadersMeanSize   Unsigned32,
    rohcContextLastPacketsRatio     RohcCompressionRatio,
    rohcContextLastHeadersRatio     RohcCompressionRatio,
    rohcContextLastPacketsMeanSize  Unsigned32,
    rohcContextLastHeadersMeanSize  Unsigned32
}

rohcContextCID OBJECT-TYPE
    SYNTAX      Unsigned32 (0..16383)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION

        "The context identifier (CID) of this context."
    REFERENCE
        "RFC 3095, Sections 5.1.1 and 5.1.3"
    ::= { rohcContextEntry 2 }

rohcContextCIDState OBJECT-TYPE
    SYNTAX      INTEGER {
                    unused(1),
                    active(2),
                    expired(3),
                    terminated(4)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "State of the CID.  When a CID is assigned to a context,
         its state changes from `unused' to `active'.  The active
         context may stop operation due to some explicit
         signalling or after observing no packet for some specified
         time.  In the first case then the CID state changes to
         `terminated', in the latter case it changes to `expired'.
         If the CID is re-used again for another context, the
         state changes back to `active'."
    ::= { rohcContextEntry 3 }

rohcContextProfile OBJECT-TYPE
    SYNTAX      Unsigned32 (0..65535)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Identifier of the profile for this context.
         The profile is identified by its index in the
         rohcProfileTable for this instance.  There MUST exist a
         corresponding entry in the rohcProfileTable using the
         value of rohcContextProfile as second part of the index
         (and using the same rohcChannelID as first part of the
         index)."
    ::= { rohcContextEntry 4 }

rohcContextDecompressorDepth OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates whether reverse decompression, for
         example as described in RFC 3095, Section 6.1, is used
         on this channel or not, and if used, to what extent.


         Its value is only valid for decompressor contexts, i.e.,
         if rohcInstanceType has the value decompressor(2).  For
         compressor contexts where rohcInstanceType has the value
         compressor(1), the value of this object is irrelevant
         and MUST be set to zero (0).

         The value of the reverse decompression depth indicates
         the maximum number of packets that are buffered, and thus
         possibly be reverse decompressed by the decompressor.
         A zero (0) value means that reverse decompression is not
         used."
    ::= { rohcContextEntry 5 }

rohcContextStorageTime OBJECT-TYPE
    SYNTAX      TimeInterval
    UNITS       "centi-seconds"
    MAX-ACCESS  read-write
    STATUS      current
    DESCRIPTION
        "The value of this object specifies how long this row
         can exist in the rohcContextTable after the
         rohcContextCIDState switched to expired(3) or
         terminated(4).  This object returns  the remaining time
         that the row may exist before it is aged out.  The object
         is initialized with the value of the  associated
         rohcContextStorageTime object.  After expiration or
         termination of the context, the value of this object ticks
         backwards.  The entry in the rohcContextTable is destroyed
         when the value reaches 0.

         The value of this object may be set in order to increase or
         reduce the remaining time that the row may exist.  Setting
         the value to 0 will destroy this entry as soon as the
         rochContextCIDState has the value expired(3) or
         terminated(4).

         Note that there is no guarantee that the row is stored as
         long as this object indicates.  In case of limited CID
         space, the instance may re-use a CID before the storage
         time of the corresponding row in rohcContextTable reaches
         the value of 0.  In this case the information stored in this
         row is not anymore available."
    ::= { rohcContextEntry 6 }

rohcContextActivationTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current

    DESCRIPTION
        "The date and time when the context started to be able to
         compress packets or decompress packets, respectively.
         The value '0000000000000000'H is returned if the context
         has not been activated yet."
    DEFVAL { '0000000000000000'H }
    ::= { rohcContextEntry 7 }

rohcContextDeactivationTime OBJECT-TYPE
    SYNTAX      DateAndTime
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The date and time when the context stopped being able to
         compress packets or decompress packets, respectively,
         because it expired or was terminated for other reasons.
         The value '0000000000000000'H is returned if the context
         has not been deactivated yet."
    DEFVAL { '0000000000000000'H }
    ::= { rohcContextEntry 8 }

rohcContextPackets OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all packets passing this context.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    ::= { rohcContextEntry 9 }

rohcContextIRs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all IR packets sent or received,
         respectively, by this context.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the

         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    REFERENCE
        "RFC 3095, Section 5.7.7.1"
    ::= { rohcContextEntry 10 }

rohcContextIRDYNs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all IR-DYN packets sent or received,
         respectively, by this context.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    REFERENCE
        "RFC 3095, Section 5.7.7.2"
    ::= { rohcContextEntry 11 }

rohcContextFeedbacks OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all feedbacks sent or received,
         respectively, by this context.

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    ::= { rohcContextEntry 12 }

rohcContextDecompressorFailures OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current

    DESCRIPTION
        "The number of all decompressor failures so far in this
         context. The number is only valid for decompressor
         contexts, i.e., if rohcInstanceType has the value
         decompressor(2).

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    ::= { rohcContextEntry 13 }

rohcContextDecompressorRepairs OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of all context repairs so far in this
         context.  The number is only valid for decompressor
         contexts, i.e., if rohcInstanceType has the value
         decompressor(2).

         Discontinuities in the value of this counter can
         occur at re-initialization of the management
         system, and at other times as indicated by the
         value of ifCounterDiscontinuityTime.  For checking
         ifCounterDiscontinuityTime, the interface index is
         required.  It can be determined by reading the
         rohcChannelTable."
    ::= { rohcContextEntry 14 }

rohcContextAllPacketsRatio OBJECT-TYPE
    SYNTAX      RohcCompressionRatio
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the compression ratio so far over all
         packets passing this context.  The compression is computed
         over all bytes of the IP packets including the IP header
         but excluding all lower layer headers."
    ::= { rohcContextEntry 15 }

rohcContextAllHeadersRatio OBJECT-TYPE
    SYNTAX      RohcCompressionRatio
    MAX-ACCESS  read-only

    STATUS      current
    DESCRIPTION
        "This object indicates the compression ratio so far over all
         packet headers passing this context.  The compression is
         computed over all bytes of all headers that are subject to
         compression for the used profile."
    ::= { rohcContextEntry 16 }

rohcContextAllPacketsMeanSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the mean compressed packet size
         of all packets passing this context.  The packet size
         includes the IP header and payload but excludes all lower
         layer headers.  The mean value is given in byte rounded
         to the next integer value."
    ::= { rohcContextEntry 17 }

rohcContextAllHeadersMeanSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the mean compressed packet header size
         of all packets passing this context.  The packet header size
         is the sum of the size of all headers of a packet that are
         subject to compression for the used profile.  The mean value
         is given in byte rounded to the next integer value."
    ::= { rohcContextEntry 18 }

rohcContextLastPacketsRatio OBJECT-TYPE
    SYNTAX      RohcCompressionRatio
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the compression ratio
         concerning the last 16 packets passing this context
         or concerning all packets passing this context
         if they are less than 16, so far.  The compression is
         computed over all bytes of the IP packets including the IP
         header but excluding all lower layer headers."
    ::= { rohcContextEntry 19 }

rohcContextLastHeadersRatio OBJECT-TYPE
    SYNTAX      RohcCompressionRatio
    MAX-ACCESS  read-only

    STATUS      current
    DESCRIPTION
        "This object indicates the compression ratio concerning the
         headers of the last 16 packets passing this context or
         concerning the headers of all packets passing this context
         if they are less than 16, so far.  The compression is
         computed over all bytes of all headers that are subject to
         compression for the used profile."
    ::= { rohcContextEntry 20 }

rohcContextLastPacketsMeanSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the mean compressed packet size
         concerning the last 16 packets passing this context or
         concerning all packets passing this context if they are
         less than 16, so far.  The packet size includes the IP
         header and payload but excludes all lower layer headers.
         The mean value is given in byte rounded to the next
         integer value."
    ::= { rohcContextEntry 21 }

rohcContextLastHeadersMeanSize OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "This object indicates the mean compressed packet header size
         concerning the last 16 packets passing this context or
         concerning all packets passing this context if they are
         less than 16, so far.  The packet header size is the sum of
         the size of all headers of a packet that are subject to
         compression for the used profile.  The mean value is given
         in byte rounded to the next integer value."
    ::= { rohcContextEntry 22 }

--
-- conformance information
--

rohcCompliances OBJECT IDENTIFIER ::= { rohcConformance 1 }
rohcGroups      OBJECT IDENTIFIER ::= { rohcConformance 2 }

--
-- compliance statements
--



rohcCompliance MODULE-COMPLIANCE
    STATUS      current
    DESCRIPTION
        "The compliance statement for SNMP entities that implement
         the ROHC-MIB.

         Note that compliance with this compliance
         statement requires compliance with the
         ifCompliance3 MODULE-COMPLIANCE statement of the
         IF-MIB (RFC2863)."
    MODULE      -- this module
    MANDATORY-GROUPS {
            rohcInstanceGroup, rohcContextGroup
    }
    GROUP   rohcStatisticsGroup
    DESCRIPTION
       "A compliant implementation does not have to implement
        the rohcStatisticsGroup."
    GROUP   rohcTimerGroup
    DESCRIPTION
       "A compliant implementation does not have to implement
        the rohcTimerGroup."
    OBJECT  rohcInstanceContextStorageTime
    MIN-ACCESS  read-only
    DESCRIPTION
        "A compliant implementation does not have to support changing
         the value of object rohcInstanceContextStorageTime."
    OBJECT  rohcContextStorageTime
    MIN-ACCESS  read-only
    DESCRIPTION
        "A compliant implementation does not have to support changing
         the value of object rohcContextStorageTime."
    GROUP   rohcContextStatisticsGroup
    DESCRIPTION
       "A compliant implementation does not have to implement
        the rohcContextStatisticsGroup."
    ::= { rohcCompliances 1 }

rohcInstanceGroup OBJECT-GROUP
    OBJECTS {
        rohcChannelType,
        rohcChannelFeedbackFor,
        rohcChannelDescr,
        rohcChannelStatus,
        rohcInstanceFBChannelID,
        rohcInstanceVendor,

        rohcInstanceVersion,
        rohcInstanceDescr,
        rohcInstanceClockRes,
        rohcInstanceMaxCID,
        rohcInstanceLargeCIDs,
        rohcInstanceMRRU,
        rohcInstanceStatus,
        rohcProfileVendor,
        rohcProfileVersion,
        rohcProfileDescr,
        rohcProfileNegotiated
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing information about
         ROHC instances, used channels and available profiles."
    ::= { rohcGroups 2 }

rohcStatisticsGroup OBJECT-GROUP
    OBJECTS {
        rohcInstanceContextsTotal,
        rohcInstanceContextsCurrent,
        rohcInstancePackets,
        rohcInstanceIRs,
        rohcInstanceIRDYNs,
        rohcInstanceFeedbacks,
        rohcInstanceCompressionRatio
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing ROHC statistics."
    ::= { rohcGroups 4 }

rohcContextGroup OBJECT-GROUP
    OBJECTS {
        rohcContextCIDState,
        rohcContextProfile,
        rohcContextDecompressorDepth
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing information about
         ROHC compressor contexts and decompressor contexts."
    ::= { rohcGroups 5 }

rohcTimerGroup OBJECT-GROUP
    OBJECTS {
        rohcInstanceContextStorageTime,

        rohcContextStorageTime,
        rohcContextActivationTime,
        rohcContextDeactivationTime

    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing statistical information
         about ROHC compressor contexts and decompressor contexts."
    ::= { rohcGroups 6 }

rohcContextStatisticsGroup OBJECT-GROUP
    OBJECTS {
        rohcContextPackets,
        rohcContextIRs,
        rohcContextIRDYNs,
        rohcContextFeedbacks,
        rohcContextDecompressorFailures,
        rohcContextDecompressorRepairs,
        rohcContextAllPacketsRatio,
        rohcContextAllHeadersRatio,
        rohcContextAllPacketsMeanSize,
        rohcContextAllHeadersMeanSize,
        rohcContextLastPacketsRatio,
        rohcContextLastHeadersRatio,
        rohcContextLastPacketsMeanSize,
        rohcContextLastHeadersMeanSize
    }
    STATUS      current
    DESCRIPTION
        "A collection of objects providing statistical information
         about ROHC compressor contexts and decompressor contexts."
    ::= { rohcGroups 7 }

END