AD | Application | AWS | Azure | Cloud | Database | Enterprise | Environmental | Event Log | File System | Infra | IoT | IT Service | Linux | Network/System | Performance | Protocol | SaaS | Security | Service Level | SNMP | Storage | VMware | VoIP | Web | Wireless

Crumbtrail

MonitorTools.com » Technical documentation » SNMP » MIB » Stratacom » BASIS-GENERIC-MIB

BASIS-GENERIC-MIB device MIB details by Stratacom

BASIS-GENERIC-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing BASIS-GENERIC-MIB.


Vendor: Stratacom
Mib: BASIS-GENERIC-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2024 [download]    (ships with advanced SNMP/MIB tools)
-- *****************************************************************
-- BASIS Generic MIB
--
-- September 2002
--
-- Copyright (c) 1996-2001, 2002 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************

-- 
-- LAST-UPDATED "200209240000Z"
-- DESCRIPTION
--     "The Card Generic mib containing generic information about
--     the service modules(Function Modules),back cards(Line Modules).
--     This contains information such as card type, back card type,
--     card status, back card status,serial number, 
--     hardware revision, firmware version,reset reasons etc."
--
-- REVISION "200209240000Z"
-- DESCRIPTION
--     "Clarified the descriptions of some of the objects.
--     Added transId OBJECT-TYPE.
--
-- REVISION "200110150000Z"
-- DESCRIPTION
-- 	"Added following enumeration in <functionModuleType>
-- 	vism-pr-8T1   (563)
--	vism-pr-8E1   (564)
--	"
-- REVISION "200110020000Z"
-- DESCRIPTION
--      "Modified description for configChangeTypeBitMap.
--       Added configChangeParentObjectIndex,
--             configChangeGrandParentObjectIndex and
--             configChangeSMSpecificObject in 
--       cardInformation Table
--      "
--
-- REVISION "200109240000Z"
-- DESCRIPTION
--     "Added following enumeration in <functionModuleType>
--      cesmB-8T1 (787)
--     "
--
-- REVISION "200109210000Z"
-- DESCRIPTION
--    "Added following enumerations in <functionModuleState>
--     notResponding(14)
--     cardinit(17)
--    "
--
-- REVISION "200108230000Z"
-- DESCRIPTION
--        CONTACT-INFO
--              "         Cisco Systems
--                        Customer Service
--
--                Postal: 170 W Tasman Drive
--                        San Jose, CA  95134
--                        USA
--
--                        Tel: +1 800 553-NETS
--
--                E-mail: cs-wanatm@cisco.com"
--    "

BASIS-GENERIC-MIB DEFINITIONS ::= BEGIN

IMPORTS 
    Counter                 FROM RFC1155-SMI
    OBJECT-TYPE             FROM RFC-1212
    DisplayString           FROM RFC1213-MIB
    cardGeneric             FROM BASIS-MIB;

cardInformation             OBJECT IDENTIFIER ::= { cardGeneric 1 }
cardInterface               OBJECT IDENTIFIER ::= { cardGeneric 2 }
cardSelfTest                OBJECT IDENTIFIER ::= { cardGeneric 3 }
 


-- ------------------------------------------------------------------
--
-- Group "cardInformation"
-- This group contains information which is generic to all cards in BASIS.
-- ------------------------------------------------------------------

moduleSlotNumber OBJECT-TYPE
    SYNTAX INTEGER (1..32)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Slot number this card is present
        "
    ::= { cardInformation 1 }

-- function Module is also referred to as front card in some instances
--
functionModuleType OBJECT-TYPE
    SYNTAX INTEGER {
        other     (1),
        asc       (2),
        bnm-T3    (10),
        bnm-E3    (11),
	bnm-155	  (12),
        srm-4T1E1 (20),
        srm-3T3   (21),
-- SRME
        srme-1OC3 (22),
        srme-1STS3(23),
        srme-NOBC(24),
        srm-3T3-NOBC(25),

        frsm-4T1  (30),
        frsm-4E1  (31),
        frsm-4T1-C(32),
        frsm-4E1-C(33),
-- HSSI
	frsm-hs1  (34),
	frsm-8T1  (35),
	frsm-8E1  (36),
        frsm-hs1b (37),
        ausm-4T1  (40),
        ausm-4E1  (41),
        ausm-8T1  (50),
        ausm-8E1   (51),
-- AUSM Model B 
        ausmB-8T1  (52),
        ausmB-8E1   (53),
 
        cesm-4T1  (60),
        cesm-4E1  (61),
        imatm-T3T1 (70),
        imatm-E3E1 (71),
-- imatm model B
	imatmB-8T1 (72),
	imatmB-8E1 (73),

	frasm-8T1 (80),

	cesm-8T1  (90),
        cesm-8E1  (91),

-- SM from Netro
	bscsm-2	   (100),
	bscsm-4	   (101),

-- testers
	atmt-8T1   (110),
	atmt-8E1   (111),
	frt-8T1    (120),
	frt-8E1    (121),

-- frsm_vhs cards
    frsm-2ct3 (130),
	frsm-2t3  (131),
	frsm-2e3  (132),
	frsm-hs2  (133),
	frsm-2t3b (134),
	frsm-2e3b (135),
	frsm-hs2b-hssi (136),
	frsm-hs2b-12In1 (137),

-- cesm_t3e3 cards
	cesm-T3   (140),
	cesm-E3   (141),

-- VISM 
        vism-8T1  (150),
        vism-8E1  (151),

-- VISM PR 
        vism-pr-8T1   (563),
        vism-pr-8E1   (564),

	cesmB-8T1 (787),

        pxm1       (1000),
        pxm1-2t3e3  (1001),
        pxm1-4oc3   (1002),
        pxm1-oc12  (1003),

        rpm        (2000),
	rpm-pr     (2001)	
                                    
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object holds the type of the card. The card 
         can type is for Processor module as well as service module.
        "
    DEFVAL { other }
    ::= { cardInformation 2 }

functionModuleDescription OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..20))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Describes the card
        "
    ::= { cardInformation 3 }

functionModuleSerialNum OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..11))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Serial number of the function Module."
    ::= { cardInformation 4 }

functionModuleHWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..2))  
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Hardware revision number for function Module."
    ::= { cardInformation 5 }

functionModuleFWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..8)) 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Firmware revision number of the function Module."
    ::= { cardInformation 6 }

functionModuleState OBJECT-TYPE
    SYNTAX  INTEGER{
        nocard (1),
        standby (2),
        active (3),
        failed (4),
        selfTest (5),
        heldInReset (6),
        boot (7),
        mismatch (8),
        unknown (9),
        coreCardMisMatch (10),
        blocked (11),
        reserved (12),
        hold (13),
        notResponding (14),
        cardinit (17)
    }
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
        "This object holds the status of a card in a particular shelf-slot.

        The possible values are :

         nocard(1)      : card not present.
         standby(2)     : card in standby state. The card is in ready state
                          and will be ready to take over the service if
                          the corresponding active card(redundant)
                          fails.
         active(3)      : card in active state. The card is providing
                          the service.
         failed(4)      : card in failed state. The card can come out
                          of this state only after user intervention
                          (Reset or running some CLI commands).

         selfTest(5)    : online diagnostics is being run in card.
         heldInReset(6) : The card configuration is being cleared.
                          No requests can be serviced.
         boot(7)        : card in boot state.
         mismatch(8)    : card is not compatible with the current
                          configuration. Card was correctly provisioned
                          earlier, however the card was replaced by
                          an incompatible card. This state can be
                          resolved by clearing the configuration, or
                          replacing with the appropriate card.
         unknown(9)     : could not determine the state
         coreCardMisMatch(10) : Controller Card(PXM/ASC etc)
                                and SRM(Service Resource Module) 
                                combination does not match.

         blocked(11)    : In case of 1:N redundancy configuration
                          the secondary card(backup card) is covering
                          one of the primary card and can not cover
                          any other card in the group if there is a failure.
                          Redundancy is blocked.

         hold(13)       : The standby controller card assumes the hold
                          state during PXM upgrades. In this state,
                          the standby PXM will be running a different
                          software but will be receiving all standby
                          updates(BRAM and Database). This state is
                          applicable only for MGX8250 Platform.
         notResponding(14): Response from the Service Module has become 
                            slow probably due to overloading of CPU.
                            No recovery action is required on user part.
                            At present, this state is applicable only
                            for Router Blade(RPM).
         cardinit(17)   : When the physical presence of card has been 
                          detected but the communication hasn't yet 
                          been established between the controller card 
                         (PXM) and Service Module.
        "
    ::= { cardInformation 7 }
 
functionModuleResetReason OBJECT-TYPE
    SYNTAX INTEGER{
        powerUp (1),
        parityError (2),
        watchDog (3),
        resourceOverflow (4),
        clrAllCnf (5),
        missingTask (6), 
        pxmLowVoltage(7),
        resetByEventLogTask(8),
        resetFromShell(9),
        unknown(10),
        resetFromPXM(11),
        resetSys(12),
        switchCC(13),
        sCacheError(14),
        swError(15),
        upgrade(16),
        restoreAllCnf(17),
        driverError(18)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Last reason for card to reset.
         
        The possible values are :
     
         powerUp(1)      : power up
         parityError(2)  : parity error
         watchDog(3)     : watchdog
         resourceOverflow (4) : resource overflow
         clrAllCnf (5)   : configuration of the shelf is cleared.
         missingTask (6) : task is missing
         pxmLowVoltage(7): low voltage detected on PXM
         resetByEventLogTask(8):
         resetFromShell(9): command is run from command shell
         unknown(10)      :
         resetFromPXM(11) : Controller Card(PXM) reset the card.
         resetSys(12)     : due to resetsys CLI Command.
         switchCC(13)     : due to switch over CLI command.
         sCacheError(14)  :
         swError(15)      : software error.
         upgrade(16)      : upgrade
         restoreAllCnf(17): restore configuration.
         driverError(18)  : driver error.

         Valid values for VISM:
             powerUp, watchDog, resetFromShell and resetFromPXM.
        "
    ::= { cardInformation 8 }

lineModuleType OBJECT-TYPE
    SYNTAX INTEGER {
       other        (1),
       	lm-ASC       (2),
       	lm-DB15-4T1  (16),
       	lm-DB15-4E1  (17),
       	lm-BNC-4E1   (18),
	lm-DB15-4T1-R(19),
	lm-DB15-4E1-R(20),
	lm-BNC-4E1-R (21),
	lm-RJ48-8T1  (22),
	lm-RJ48-8E1  (23),
	lm-SMB-8E1   (24),
	lm-RJ48-T3T1 (25),
	lm-RJ48-E3E1 (26),
	lm-RJ48-T3E1 (27),
	lm-SMB-E3E1  (28),
	lm-RJ48-E3T1 (29),
	lm-SMB-T3E1 (30),
        lm-T3E3-D    (32),
        lm-T3E3-B    (33),
	lm-155-SMF   (34),
	lm-155-UTP   (35),
	lm-RJ48-8T1-R(48),
	lm-RJ48-8E1-R(49),
	lm-SMB-8E1-R (50),
	lm-3T3-B      (51),
-- HSSI/X.21 
	lm-HS1-4X21  (60),
	lm-HS1-3HSSI (61),
-- HSSI/X.21
	lm-HS1-4V35 (62),

	lm-12In1-8s (63),

        lm-BSCSM-2   (70),
	lm-BSCSM-4   (71),

	lm-BNC-2T3 (80),
	lm-BNC-2E3 (81),

	pxm-ui		(500),
	smfir-1-622	(501),
	smflr-1-622	(502),
	smfir15-1-622	(503),
	smflr15-1-622	(504),
	mmf-4-155	(505),
	smfir-4-155	(506),
	smflr-4-155	(507),
	rj45-fe		(511),
	mmf-fe		(512),
	mmf-fddi	(513),
	smf-fddi	(514),
	rj45-4e		(515),
	pxm-ui-s3       (1006),
-- SRME back card
	lm-srme-1OC3-smlr   (1050),
	lm-srme-1OC3-smir   (1051),
	lm-srme-1OC3-smb    (1052)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object contains the Line Module(back card) type.
         Physically it is behind the backplane, normally with
         connectors for physical devices.
         These are specific to the front or functional modules.
        "
    DEFVAL { other }
    ::= { cardInformation 9 }

lineModuleDescription OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..20))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object contains description of the line module."
    ::= { cardInformation 10 }

lineModuleSerialNum OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..11))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object contains Serial number of the line module."
    ::= { cardInformation 11 }

lineModuleHWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..2)) 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object contains Hardware revision for line module."
    ::= { cardInformation 12 }

lineModuleFWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..8))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Firmware revision for line module.
        The current version does not have any
        firmware, hence will always contains
        zero length octet string."
    ::= { cardInformation 13 }

lineModuleState OBJECT-TYPE
    SYNTAX INTEGER {
       notPresent (1),
       present    (2),
       invalid    (3)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION 
        "line module status."
    ::= { cardInformation 14 }

moduleTrapAlarmSeverity OBJECT-TYPE
    SYNTAX INTEGER {
       minor    (1),
       major    (2),
       dontCare (3),
       critical (4),
       error    (5),
       warning  (6),
       notice   (7),
       info     (8)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object is sent to managers as part of all Trap PDUs, to
         determine the module alarm severity. An implementation may
	 not support all the possible values.

	 The Possible values are :

	  major    (1) : Major Service has been impacted
	  minor    (2) : Minor Service has been lost
	  dontCare (3) : severity is not applicable
          critical (4) : affects existing data traffic
          error    (5) : error has occurred
          warning  (6) : a threshold has been reached
          notice   (7) : a normal but significant event has occurred
          info     (8) : informational
        "
    ::= { cardInformation 15 }

mibVersionNumber OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "MIB version number. Updated when any part of
         the MIB changes. 
        "
    DEFVAL { 2 }
    ::= { cardInformation 16 }

configChangeTypeBitMap OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Configuration change Type BitMap
	 bit 0 set = Card Configuration Change
	 bit 1 set = Line Configuration Change
	 bit 2 set = Port Configuration Change
	 bit 3 set = Chan Configuration Change
	 bit 4 set = STUN protocol group configuration Change
	 bit 5 set = STUN port configuration Change
	 bit 6 set = STUN route configuration Change
	 bit 7 set = BSTUN protocol configuration Change
	 bit 8 set = BSTUN port configuration Change
	 bit 9 set = BSTUN route configuration Change
	 bit 10 set = FRASBNN route configuration Change
	 bit 11 set = FRASBAN route configuration Change
	 bit 12 set = SDLC port configuration Change
	 bit 13 set = SDLC LS configuration Change
	 bit 14 set = BSC port configuration Change
	 bit 15 set = LLC port configuration Change
	 bit 16 set = card LCN partition change (controller based only)
	 bit 17 set = port resource partition change (under any partition type)
	 bit 18 set = VISM Endpoint Configuration Change
	 bit 19 set = Egress Q configuration change

	 default value is 0, no change

	 This object makes sense only in traps. A GET
	 on this may not return a Useful result.

	 Bit 19 is not applicable for MGX 8850 Release 1.x.x
	 and MGX 8220

        "
    DEFVAL { 0 }
    ::= { cardInformation 17 }

configChangeObjectIndex OBJECT-TYPE
    SYNTAX  INTEGER (1..1024)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Configuration change object index, could be 
	line number or port number or channel number
	depends on the type bitmap, for port resouce
	partition change (bit 17), this index is actually
	constructed by (portNum << 16 | controller)
	because the table has two indices.
        When the 'Line Configuration Change' bit is set,
        the configChangeObjectIndex has the following special meanings
        in IMATM and FRSM-2CT3 cards:
        IMATM - configChangeObjectIndex range between 1..8 
                indicates that the configuration change refers 
                to the DS1 line index. A value of 9 indicates that 
                the configuration change refers to the DS3 line index.
        FRSM-2CT3 - configChangeObjectIndex range between 1..56
                    indicates that the configuration change refers 
                    to the DS1 line index. A value of (128 + n)
                    refers to DS3 line index numbered 'n'.

         This object makes sense only in traps. A GET
         on this may not return a Useful result. 
        "
    ::= { cardInformation 18 }

configChangeStatus OBJECT-TYPE
    SYNTAX  INTEGER (0..3)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object is applicable only for traps.
        The SNMP operation may not be meaningful.

        The value contained in this object is same as
        the value of the other objects which are used
        for adding/deleting/modifying the row.

        The possible values are 
        0 - No meaning and is not applicable.
        1 - add    [ Row added ]
        2 - delete [ Row deleted ]
        3 - mod    [ Row modified ]
  

        This value and value contained in configChangeTypeBitMap
        represent the configuration change operation.

	The default value is 0 and it does not
        represent any status."
    DEFVAL {0}
    ::= { cardInformation 19 }
 
cardIntegratedAlarmBitMap OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Bit position represents the different types of alarm
         for ASC:
                bit 0: ShelfFunctionModuleState (BNM only)
                        (failed/boot/mismatch/heldinReset)
                bit 1: LineModuleState (BNM only) (notPresent/invalid)
                bit 2: ASMPhysicalAlarmState (BNM only)
                bit 3: ATMLMIFailure (ASC only)
                bit 4: LineAlarmState (BNM only)
                bit 5: LineStatisticalAlarmState (BNM only)
                bit 6: PLCPAlarmState (BNM only)
                bit 7: PLCPStatisticalAlarmState (BNM only)
                bit 8: SmConnectionFailureAlarm
        for SM:
                bit 0: ShelfFunctionModuleState
                        (failed/boot/mismatch/heldinReset)
                bit 1: LineModuleState  (notPresent/invalid)
                bit 2: PortLMIFailure
                bit 3: LineAlarmState
                bit 4: LineStatisticalAlarmState
                bit 5: FrameRelayPortState (RemoteLoopback/
                                            FailedDueToLine/
                                            FailedDueToSig)
                bit 6: ChannelState

	for PXM/SRM Only (MGX8850 Platfrom):
		Only those marked with SRM are valid for both PXM/SRM.
                The rest are valid only for PXM.
		bit 0	: ShelfFunctionModuleState
		bit 1	: Backcard Line Module		(SRM/PXM)
		     	  This Alarm is generated when the Line Module
                          (Trunk Backcard) is removed or goes to a mismatch
                          state(or backcard type is unknown).
		bit 2  	: Backcard UIModule
			  This Alarm is generated when the UI backcard is
                          removed or goes to a mismatch state
                          (or backcard type is unknown).
		bit 3  	: ASM Physical Alarm
			  This specifies whether any of the 
                          environmental monitoring components like 
                          Temperature, Voltage Supply, Fan Speed
                          have gone into alarm.
		bit 4	: ATM LMI Failure 
		bit 5	: Line Alarm	(SRM/PXM)
		bit 6	: Line Statistical Alarm	(SRM/PXM)
		bit 7  	: Lines Alarm	(SRM/PXM)
		bit 8   : PLCP Alarm
		bit 9   : PLCP Statistical Alarm
		bit 10 	: Connections exist on removed SM
		bit 11 	: Disk related Failure on first PXM slot
		bit 12  : Disk related Failure on second PXM slot
			  The Disk Alarms are generated when any of the
                          file operations on Disk like open,read,write,
                          lseek etc fail. 
			VSM Alarms
		bit 13 	: Port LMI Failure
		bit 14  : Port State Alarm
		bit 15	: Channel Shelf Alarm

		bit 16	: Taskmon Task Suspended
		bit 17	: Excess Power Consumption
		bit 30  : bit set(1) major alarm, else (0) minor alarm

        "
    DEFVAL {0}
    ::= { cardInformation 20 }


cleiCode OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..10))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Common Language Equipment(CLEI) Code.
        "
    ::= { cardInformation 21 }


macAddress OBJECT-TYPE
    SYNTAX  DisplayString
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "Ethernet address (base address) stored in 
             NVRAM, entered by manfacturing.
            "
    ::= { cardInformation 22 }

macAddrBlkSize OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The MAC address block size, entered by
         manufacturing.
        "
    ::= { cardInformation 23 }

finalTestTechnician OBJECT-TYPE
    SYNTAX  DisplayString (SIZE (0..6))
    ACCESS  read-only
    STATUS  mandatory
    DESCRIPTION
            "The Final Test Technician Employee Identification Number.
            "
    ::= { cardInformation 24 }

hwFailures OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Hardware failure code."
    ::= { cardInformation 25 }


hwHistory OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "RMA Test History - RMA Failure Code."
    ::= { cardInformation 26 }


secLineModuleType OBJECT-TYPE
    SYNTAX INTEGER {
       other        (1),
       	lm-ASC       (2),
       	lm-DB15-4T1  (16),
       	lm-DB15-4E1  (17),
       	lm-BNC-4E1   (18),
	lm-DB15-4T1-R(19),
	lm-DB15-4E1-R(20),
	lm-BNC-4E1-R (21),
	lm-RJ48-8T1  (22),
	lm-RJ48-8E1  (23),
	lm-SMB-8E1   (24),
	lm-RJ48-T3T1 (25),
	lm-RJ48-E3E1 (26),
	lm-RJ48-T3E1 (27),
	lm-SMB-E3E1  (28),
	lm-RJ48-E3T1 (29),
	lm-SMB-T3E1 (30),
        lm-T3E3-D    (32),
        lm-T3E3-B    (33),
	lm-155-SMF   (34),
	lm-155-UTP   (35),
	lm-RJ48-8T1-R(48),
	lm-RJ48-8E1-R(49),
	lm-SMB-8E1-R (50),
	lm-3T3-B      (51),
	lm-HS1-4X21  (60),
	lm-HS1-3HSSI (61),
-- HSSI/X.21
	lm-HS1-4V35 (62),

	lm-12In1-8s (63),

        lm-BSCSM-2   (70),
	lm-BSCSM-4   (71),

	lm-BNC-2T3 (80),
	lm-BNC-2E3 (81),

	pxm-ui		(500),
	smfir-1-622	(501),
	smflr-1-622	(502),
	smfir15-1-622	(503),
	smflr15-1-622	(504),
	mmf-4-155	(505),
	smfir-4-155	(506),
	smflr-4-155	(507),
	rj45-fe		(511),
	mmf-fe		(512),
	mmf-fddi	(513),
	smf-fddi	(514),
	rj45-4e		(515),
	pxm-ui-s3       (1006)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object contains the type of secondary
        line module(back card).
        Physically it is the bottom card behind the backplane.  
        Normally with connectors for physical devices.
        These are specific to the front or function modules.
        This Object is applicable only to selected MGX switches.
        "
    DEFVAL { other }
    ::= { cardInformation 27 }

secLineModuleDescription OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..20))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Description of the Secondary line module.
         This Object is applicable only to selected MGX switches.
        "
    ::= { cardInformation 28 }

secLineModuleSerialNum OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..11))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Serial number of the secondary(bottom) line module.
         This object is applicable only to selected MGX switches.
        "
    ::= { cardInformation 29 }

secLineModuleHWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..2)) 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Hardware revision for secondary (bottom) line module 
         This object is applicable only to selected MGX switches.
        "
    ::= { cardInformation 30 }

secLineModuleFWRev OBJECT-TYPE
    SYNTAX DisplayString (SIZE (0..8))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Firmware revision for Secondary line module
         This object is applicable only to selected MGX switches.
         If there is no Firmware revision, 
         then this object returns 0.
        "
    ::= { cardInformation 31 }
 

secLineModuleState OBJECT-TYPE
    SYNTAX INTEGER {
       notPresent (1),
       present    (2),
       invalid    (3)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "line module status  of secondary (bottom) back card.
         This object is applicable only to selected MGX switches."
    ::= { cardInformation 32 }

configChangeParentObjectIndex OBJECT-TYPE 
    SYNTAX  INTEGER (1..1024) 
    ACCESS read-only 
    STATUS mandatory
    DESCRIPTION
       " Parent object index, could be
           - line index
           - port index

        This object will indicate the index of the immediate
        higher level object (line or port) of configChangeObjectIndex.
        This object is applicable only when configChangeObjectIndex 
        represents a channel, port, egress Q or resource partition
        index.

        Following specifies the mapping between the 
        configChangeObjectIndex and its corresponding
        configChangeParentObjectIndex.

        configChangeObjectIndex         configChangeParentObjectIndex
        -----------------------         -----------------------------
        Port Index                      Line Index
        Egress Q Index                  Port Index
        Resource Partition Index        Port Index
        Channel Index                   Port Index

        When the 'Port Configuration Change' bit is set,
        the configChangeParentObjectIndex will represent
        a 'Line Index' which in turn has the following
        special meaning in FRSM-2CT3 cards.

        - configChangeParentObjectIndex range between 1..56
          indicates that the configuration change refers to the DS1 line
          index. A value of (128 + n) refers to DS3 line index 
          numbered 'n'.

        This object object is applicable only in traps.
        A GET on this may not return a useful result.

        This object Object is not applicable to MGX 8850 
        Release 1.x.x and MGX8220
       "
      ::= { cardInformation 33 }

configChangeGrandParentObjectIndex OBJECT-TYPE 
    SYNTAX  INTEGER (1..1024) 
    ACCESS read-only 
    STATUS mandatory
    DESCRIPTION
       " Grand Parent object index, could be
         - line index

         This object will indicate the index of the immediate
         higher level object (line) of configChangeParentObjectIndex.
         This object is applicable only when configChangeParentObjectIndex 
         represents a port index.

         Following specifies the mapping between the 
         configChangeParentObjectIndex and its corresponding
         configChangeGrandParentObjectIndex.

         When the 'Port Configuration Change' bit is set 
         the configChangeGrandParentObjectIndex will represent
         a 'Line Index' which in turn has the following
         special meaning in FRSM-2CT3 cards.

        - configChangeParentObjectIndex range between 1..56
          indicates that the configuration change refers to the DS1 line
          index. A value of (128 + n) refers to DS3 line index 
          numbered 'n'.

         This object is applicable only in traps.
         A GET on this may not return a useful result.

         This object is not applicable to MGX 8850 
         release 1.x.x and MGX8220."

     ::= { cardInformation 34 }

configChangeSMSpecificObject OBJECT-TYPE 
    SYNTAX  INTEGER (0..'ffffff'h)
    ACCESS read-only 
    STATUS mandatory
	DESCRIPTION
       " configChangeSMSpecificObject is a generic object
	     which is Service Module Specific. It can be used
		 for different purposes in different cards. The
		 usage of the same with regard to very card type is
		 listed below.

		 FRSM-8T1E1 - used to store portDs0ConfigBitMap
		 FRSM-VHS   - used to store portDs0ConfigBitMap
		 CESM-8T1E1 - used to store cesPortDs0ConfigBitMap
		 CESM-T3E3  - not used
		 AUSM-8T1E1 - not used

         This object is not applicable to MGX 8850 
         Release 1.x.x and MGX8220." 
     ::= { cardInformation 35 }

transId OBJECT-TYPE
    SYNTAX  INTEGER (0..'7fffffff'h)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Per card transaction ID. This object is used to keep 
        track of configuration change on the card.
        The transId will be incremented by one for every
        configuration change on the card."
     ::= { cardInformation 36 }


-- ******************************************************************
--
-- Group "Interface"
-- This group contains list of physical interfaces and service types
-- available on a card. 
-- Different line types are e.g. DS1,DS3,OC3 etc.
-- Different services are e.g. ATM,FrameRelay etc.
-- Any combination of line type and service type are possible for a card.
--
-- ******************************************************************

interfaceNumOfValidEntries        OBJECT-TYPE
    SYNTAX INTEGER
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Number of rows in interface Table
         The number represents the physcial interfaces the module has.
        "
    ::= { cardInterface 2 }

interfaceLineTable   OBJECT-TYPE
    SYNTAX SEQUENCE OF InterfaceLineEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "This table has list of the physical interfaces 
         and the services available on this module.
        "
    ::= { cardInterface 1 }

interfaceLineEntry OBJECT-TYPE
    SYNTAX InterfaceLineEntry
    ACCESS not-accessible
    STATUS mandatory
    DESCRIPTION
        "An entry for physical interface
        "
    INDEX { interfaceLineNum }
    ::= { interfaceLineTable 1 }

InterfaceLineEntry ::= 
    SEQUENCE {
        interfaceLineNum             INTEGER,
        interfaceLineType            INTEGER,
        interfaceNumOfPortsPerLine   INTEGER,
        interfaceServiceType         INTEGER,
        interfaceNumOfPVC            INTEGER,
        interfaceNumOfEgressQueue    INTEGER
    }

interfaceLineNum OBJECT-TYPE
    SYNTAX INTEGER (1..10)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "An index to uniquely indentify the physical interface and service.
         Indices 1..8 are used for VISM-8T1/E1.
        "
    ::= { interfaceLineEntry 1 }

interfaceLineType OBJECT-TYPE
    SYNTAX INTEGER {
        other(1),
        ds1(18),
        e1(19),
        ethernet-3Mbit (26),
        ds3(30),
        rs232(33),
	v35(45),
-- HSSI/X.21 
-- Unable to find for X.21 interface
	hssi(46)
-- HSSI/X.21
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "This object indicates the type of interfaces provided by 
        this Module. These numbers are from RFC1700."
    ::= { interfaceLineEntry 2 }

interfaceNumOfPortsPerLine OBJECT-TYPE
    SYNTAX INTEGER (0..65535)
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The number of physical ports of the line type.
         VISM has a port, but is not linked to these physical lines,
         hence value=0 is returned.
        "
    DEFVAL {672}
    ::= { interfaceLineEntry 3 }

interfaceServiceType OBJECT-TYPE
    SYNTAX INTEGER {
        other(1),
        ethernet-3Mbit (26),
        slip (28),
        frameRelay(32),
        atm(37),
        voice(42)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The services available on the interfaceLineType object
        "
    ::= { interfaceLineEntry 4 }

interfaceNumOfPVC OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The Max number of Permanent Virtual Channels available per physical
         line (line as defined in interfaceLineType).
         VISM has a PVC but is not linked to the lines,
         hence value=0 is returned.
        "
    ::= { interfaceLineEntry 5 }

interfaceNumOfEgressQueue OBJECT-TYPE
    SYNTAX INTEGER 
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "The Max number of Queues per port.
         Value=0 is returned for VISM card.
        "
    ::= { interfaceLineEntry 6 }

-- ----------------------------------------------------------------
--
-- Group "cardTest"
-- The cardTest group contains self test results.
-- All cards in BASIS have this group defined.
--
-- ----------------------------------------------------------------

selfTestEnable OBJECT-TYPE
    SYNTAX INTEGER {
        disable  (1),
        enable   (2)
    }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This object indicates the self test state
         1 ==> self test enabled
         2 ==> self test disabled
        "
    DEFVAL { disable }
    ::= { cardSelfTest 1 }

selfTestPeriod OBJECT-TYPE
    SYNTAX INTEGER (1..60)
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "Interval (in minutes) for self test.
        "
    DEFVAL { 1 }
    ::= { cardSelfTest 2 }

selfTestState OBJECT-TYPE
    SYNTAX INTEGER {
        passed (1),
        failed (2)
    }
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Self test results for the module.
        "
    ::= { cardSelfTest 3 }

selfTestResultDescription OBJECT-TYPE
    SYNTAX DisplayString (SIZE(0..40))
    ACCESS read-only
    STATUS mandatory
    DESCRIPTION
        "Self test Result description
        "
    ::= { cardSelfTest 4 }

selfTestClrResultButton OBJECT-TYPE
    SYNTAX INTEGER {
        other (1),
        clear (2)
        }
    ACCESS read-write
    STATUS mandatory
    DESCRIPTION
        "This object is used for clearing the result
        of an online diagnostics(or other self tests)."
    ::= { cardSelfTest 5 }


controlMsgCounter  OBJECT IDENTIFIER ::= { cardGeneric 4 }

riscXmtCtrlMsg OBJECT-TYPE
    SYNTAX  Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "The number of control Frames transmitted to SAR (from RISC)
     maintained by RISC
    "
    ::= { controlMsgCounter 1 }

riscRcvCtrlMsg OBJECT-TYPE
    SYNTAX  Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "The number of control Frames received from SAR (to RISC)
     maintained by RISC
    "
    ::= { controlMsgCounter 2 }

sarXmtCtrlMsg  OBJECT-TYPE
    SYNTAX  Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "The number of control Frames transmitted to RISC from SAR 
     maintained by SAR (should be equal to (riscRcvCtrlMsg)
    "
    ::= { controlMsgCounter 3 }

sarRcvCtrlMsg OBJECT-TYPE
    SYNTAX  Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "The number of control Frames received to SAR from RISC
     maintained by SAR (should be equal to (riscXmtCtrlMsg)
    "
    ::= { controlMsgCounter 4 }

sarCtrlMsgDiscLenErr  OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "Total control (management) frames (for MGX8800) or
    cells(for MGX8220) discarded due to illegal length error
    "
    ::= { controlMsgCounter 5 }
 
sarCtrlMsgDiscCRCErr  OBJECT-TYPE
    SYNTAX Counter
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "Total control (management) frames (MGX8800) or cells(MGX8220) 
     discard due to illegal CRC error.
    "
    ::= { controlMsgCounter 6 }

sarCtrlMsgDiscUnknownChan    OBJECT-TYPE
    SYNTAX  Counter 
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "Count of discarded control message due to unknown channel error."
    ::= { controlMsgCounter 7 }

sarCtrlMsgLastUnkownChan    OBJECT-TYPE
    SYNTAX  INTEGER
    ACCESS read-only
    STATUS  mandatory
    DESCRIPTION
    "The control cell header Rcvd of the last unknown channel."
    ::= { controlMsgCounter 8 }

ctrlMsgClrButton    OBJECT-TYPE
    SYNTAX  INTEGER {
       other (1),
       clear (2)
       }
    ACCESS read-write
    STATUS  mandatory
    DESCRIPTION
    "This object is used for clearing the messages
    in controlMsgCounter group."
    ::= { controlMsgCounter 9 }


sarChannelCounter  OBJECT IDENTIFIER ::= { cardGeneric 5 }

-- ----------------------------------------------------------------
--
-- Group "sarCounters"
-- This group contains list of SAR counters and RISC counters
-- This group is common to all cards. All cards in BASIS have
-- SAR and RISC counters.
--
-- ----------------------------------------------------------------

-- ---------------------------------------------------------------------
-- 
--         SAR channel counters group
--
--         These are counter maintained by the SAR and supplied to the
--         manager by RISC, the counters are per VC and counters are
--         for ATM cells
--
-- cell counters
-- ---------------------------------------------------------------------

chanNumOfValidEntries OBJECT-TYPE
	SYNTAX INTEGER
	ACCESS read-only
	STATUS mandatory
	DESCRIPTION
		"Number of entries in the sar channel table
		"
	::= { sarChannelCounter	2 }

sarChannelCounterTable	OBJECT-TYPE
	SYNTAX	SEQUENCE OF SarChannelCounterEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
            "The table is for logical channels
            This table contains the counters for cells 
            transmitted on each channel."
	::= { sarChannelCounter 1 }

sarChannelCounterEntry	OBJECT-TYPE
	SYNTAX	SarChannelCounterEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		" An entry for logical channel
		"
	INDEX	{ sarShelfNum, sarSlotNum, sarChanNum }
	::= { sarChannelCounterTable 1 }

SarChannelCounterEntry ::=
	SEQUENCE {
            sarShelfNum 	        INTEGER,
		sarSlotNum 	        INTEGER,
		sarChanNum        	INTEGER,
-- Xmt Cell stats
		xmtCells		Counter,
		xmtCellsCLP		Counter,
		xmtCellsAIS		Counter,
		xmtCellsFERF	        Counter,
		xmtCellsBCM		Counter,
		xmtCellsEnd2EndLpBk     Counter,
		xmtCellsSegmentLpBk	Counter,
		xmtCellsDiscShelfAlarm	Counter,
-- Rcv Cell stats
		rcvCells		Counter,
		rcvCellsCLP		Counter,
		rcvCellsAIS		Counter,
		rcvCellsFERF	        Counter,
		rcvCellsBCM		Counter,
		rcvCellsEnd2EndLpBk	Counter,
		rcvCellsSegmentLpBk	Counter,
		rcvCellsDiscOAM	        Counter,
		sarClrButton            INTEGER 
}

sarShelfNum OBJECT-TYPE
 	SYNTAX	INTEGER (1..4)
 	ACCESS	read-only
 	STATUS	mandatory
 	DESCRIPTION		  
 		"Shelf number
 		"
 	::= { sarChannelCounterEntry	1 }
 
sarSlotNum OBJECT-TYPE
 	SYNTAX	INTEGER (1..16)
 	ACCESS	read-only
 	STATUS	mandatory
 	DESCRIPTION		  
            "Slot number, the slot and shelf info is required here
            because BSC sends the OAM cells for the FRSM cards 
            that have failed BSC could have upto 4000 connections
            in this table."
	::= { sarChannelCounterEntry	2 }

sarChanNum OBJECT-TYPE
	SYNTAX	INTEGER (0..4015)
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		" BSC could have upto 4000 connections in this table
		"
	::= { sarChannelCounterEntry	3 }

xmtCells OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of cells transmitted on this channel.
		"
	::= { sarChannelCounterEntry	4 }


xmtCellsCLP OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
	    "The total number of CLP cells that were 
            transmitted on this channel."
	::= { sarChannelCounterEntry	5 }

xmtCellsAIS OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of AIS cells that were transmitted on this channel.
		"
	::= { sarChannelCounterEntry	6 }

xmtCellsFERF OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of FERF cells that were transmitted on this channel.
		"
	::= { sarChannelCounterEntry	7 }

xmtCellsBCM OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
            "The number of BCM cells that were transmitted on this channel."
	::= { sarChannelCounterEntry	8 }

xmtCellsEnd2EndLpBk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
            "The number of End2End loop cells that were transmitted on 
             this channel."
	::= { sarChannelCounterEntry	9 }

xmtCellsSegmentLpBk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
	    "The number of segment loop cells that were transmitted 
             on this channel."
	::= { sarChannelCounterEntry	10 }

xmtCellsDiscShelfAlarm OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of cells discard due to Shelfalarm on this channel.
		"
	::= { sarChannelCounterEntry	11 }

-- receiver cell counters

rcvCells OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of cells that were received on this channel.
		"
	::= { sarChannelCounterEntry	12 }

rcvCellsCLP OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of CLP cells that were received on this channel.
		"
	::= { sarChannelCounterEntry	13 }

rcvCellsAIS OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of AIS cells that were received on this channel.
		"
	::= { sarChannelCounterEntry	14 }

rcvCellsFERF OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of FERF cells that were received on this channel.
		"
	::= { sarChannelCounterEntry	15 }

rcvCellsBCM OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of BCM cells that were received on this channel.
		"
	::= { sarChannelCounterEntry	16 }

rcvCellsEnd2EndLpBk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
            "The number of End2End loop cells that were received on 
             this channel."
	::= { sarChannelCounterEntry	17 }

rcvCellsSegmentLpBk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
	    "The number of segment loop cells that were received on
             this channel. "
	::= { sarChannelCounterEntry	18 }

rcvCellsDiscOAM OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION		  
		"The number of cells that had CRC error on
		 OAM cells
		"
	::= { sarChannelCounterEntry	19 }

sarClrButton OBJECT-TYPE
    SYNTAX  INTEGER {
       other (1),
       clear (2)
       }
	ACCESS read-write
	STATUS mandatory
	DESCRIPTION
		"clear the counters in the table
		"
	::= { sarChannelCounterEntry	20 }

END