You are here:

MonitorTools.com > Technical documentation > SNMP > MIB > Stratacom > CISCO-MGX82XX-RPM-CONN-MIB
ActiveXperts Network Monitor 2019##AdminFavorites

CISCO-MGX82XX-RPM-CONN-MIB by vendor Stratacom

CISCO-MGX82XX-RPM-CONN-MIB file content

The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing CISCO-MGX82XX-RPM-CONN-MIB.


Vendor: Stratacom
Mib: CISCO-MGX82XX-RPM-CONN-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
-- *****************************************************************
-- CISCO-MGX82XX-RPM-CONN-MIB.my
--  RPM Connection MIB in MGX8250 products.
--
-- September 2002, Subra Hegde
--
-- Copyright (c) 2002 by cisco Systems, Inc.
-- All rights reserved.
-- 
-- *****************************************************************

CISCO-MGX82XX-RPM-CONN-MIB DEFINITIONS ::= BEGIN
IMPORTS
	MODULE-IDENTITY,
	OBJECT-TYPE,
        Integer32
                                 FROM SNMPv2-SMI
	MODULE-COMPLIANCE,
        OBJECT-GROUP             FROM SNMPv2-CONF
        TEXTUAL-CONVENTION       FROM SNMPv2-TC
	rpmChanGrp		 FROM BASIS-MIB
	ciscoWan                 FROM CISCOWAN-SMI;

ciscoMgx82xxRpmConnMIB	MODULE-IDENTITY
	LAST-UPDATED	"200209080000Z"
	ORGANIZATION	"Cisco Systems, Inc."
	CONTACT-INFO
		"	Cisco Systems
			Customer Service

		Postal: 170 W Tasman Drive
			San Jose, CA 95134
			USA

			Tel: +1 800 553-NETS

		E-mail: cs-wanatm@cisco.com"

    DESCRIPTION
	"The connection MIB module for RPM(Router Blade)
        service module in MGX8250/MGX8230 products.

        The 'channel' and 'connection' and 'connection endpoint'
        mean same in this MIB."

    REVISION    "200209080000Z"
    DESCRIPTION
        "Initial version of the MIB.

        The content of this MIB was originally available
        in CISCO-WAN-AXIPOP-MIB defined using SMIv1.
        The applicable objects from CISCO-WAN-AXIPOP-MIB
        are defined using SMIv2 in this MIB. Also the
        descriptions of some of the objects have been 
        modified."
	::= { ciscoWan 62 }

RpmNsapAddress ::= TEXTUAL-CONVENTION
	STATUS	current
	DESCRIPTION
	    "ATM address used by the networking entity. The only 
	    address type presently supported is NSAP (20 octets)"
	SYNTAX	OCTET STRING (SIZE(20))

rpmChanGrpTable OBJECT-TYPE
    SYNTAX     SEQUENCE OF RpmChanGrpEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION
	"This table contains endpoint configuration
        information for connections applicable to
        RPM service module."
	::= { rpmChanGrp 1 }

rpmChanGrpEntry OBJECT-TYPE
    SYNTAX     RpmChanGrpEntry
    MAX-ACCESS not-accessible
    STATUS     current
    DESCRIPTION 
	"An entry for logical channel. Each entry
        corresponds to a connection endpoint identified
        by Slot number and channel number."
    INDEX   { rpmChanSlotNum, rpmChanNum }
    ::= { rpmChanGrpTable 1 }

RpmChanGrpEntry ::=
	SEQUENCE {
	    rpmChanSlotNum           Integer32,
    	    rpmChanInterface	     Integer32,
	    rpmChanNum	             Integer32,
	    rpmChanRowStatus	     INTEGER,
	    rpmChanVcd		     Integer32,
	    rpmChanVpi		     Integer32,
	    rpmChanVci		     Integer32,
	    rpmChanSubInterface	     Integer32,
	    rpmChanLocalVpi	     Integer32,
	    rpmChanLocalVci	     Integer32,
	    rpmChanLocalNsap	     RpmNsapAddress,
	
	    rpmChanRemoteVpi	     Integer32,
	    rpmChanRemoteVci	     Integer32,
	    rpmChanRemoteNsap	     RpmNsapAddress,

	    rpmChanType  	     INTEGER,
	    rpmChanConnType	     INTEGER,
	    rpmChanServiceType	     INTEGER,

	    rpmChanMastership	     INTEGER,
	    rpmChanRtePriority       Integer32,
	    rpmChanMaxCost           Integer32,
	    rpmChanRestrictTrkType   INTEGER,

	    rpmChanPCR		     Integer32,
	    rpmChanRemotePCR	     Integer32,
	    rpmChanMCR		     Integer32,
	    rpmChanRemoteMCR	     Integer32,
	    rpmChanPercentUtil	     Integer32,
	    rpmChanRemotePercentUtil Integer32,

	    rpmChanMidLow            Integer32,
	    rpmChanMidHigh           Integer32,
	    rpmChanBurstSize	     Integer32,
	    rpmChanEncapType	     INTEGER,
	    rpmChanInArpFreq	     Integer32,
	    rpmChanOAMloopback	     Integer32,
	    rpmChanState	     INTEGER,
	    rpmChanVirtualTemplate   Integer32,
	    rpmChanAbrRDF	     Integer32,
	    rpmChanAbrRIF	     Integer32
	}

rpmChanSlotNum	OBJECT-TYPE
	SYNTAX     Integer32  (1..30)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Specifies the slot number of the RPM card."
	::= { rpmChanGrpEntry 1 }

rpmChanInterface OBJECT-TYPE
	SYNTAX 	   Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	"This is the RPM's backplane interface.
        Currently there is only one interface."
	::= { rpmChanGrpEntry 2 }

rpmChanNum OBJECT-TYPE
	SYNTAX 	   Integer32 (16..4095)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object identifies the channel number.
            This is also called Logical Connection Number(LCN).
            This is a unique number which identifies a
	    connection. 
            The LCN maps VPI and VCI.
	    For VCC, VCI range is 1..3825, and LCN range is 16..3840. 
	    LCN = VCI + 16.
	    For VPC, VPI range is 1..255 and LCN range is 3841..4095. 
	    LCN = VPI + 3840."
	::= { rpmChanGrpEntry 3 }

rpmChanRowStatus  OBJECT-TYPE
    SYNTAX  INTEGER {
                add(1),
                del(2),
                mod(3)
            }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
	"This indicates the status of this channel.
         
         add(1) : Channel is added.
         del(2) : channel is deleted.
         mod(3) : Set to this value before modifying objects
                  related to connection endpoints."
	::= { rpmChanGrpEntry 4 }

rpmChanVcd OBJECT-TYPE
	SYNTAX 	   Integer32 (0..4095)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Virtual Circuit Descriptor. A unique number
             which identifies a connection."
	::= { rpmChanGrpEntry 5 }

rpmChanVpi OBJECT-TYPE
	SYNTAX 	   Integer32 (0..255)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "The VPI value for this channel.
	    For VPC, VPI range is 1..255 and 
            LCN range is 3841..4095. 
	    LCN = VPI + 3840"
	::= { rpmChanGrpEntry 6 }

rpmChanVci OBJECT-TYPE
	SYNTAX     Integer32 (0..65535)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "The VCI value for this channel.
	    For VCC, VCI range is 1..3825, and 
            LCN range is 16..3840. 
	    LCN = VCI + 16."
	::= { rpmChanGrpEntry 7 }

rpmChanSubInterface OBJECT-TYPE
	SYNTAX 	   Integer32 (1..2147483647)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is the RPM's backplane sub-interface."
	::= { rpmChanGrpEntry 8 }

rpmChanLocalVpi OBJECT-TYPE
	SYNTAX 	   Integer32 (0..255)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This VPI together with the local VCI 
            and NSAP represents the local end point 
            in this connection. The VPI value is zero for
            rpmChanConnType value of vcc(2)."
	::= { rpmChanGrpEntry 9 }

rpmChanLocalVci OBJECT-TYPE
	SYNTAX 	   Integer32 (0..65535)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This VCI together with the local 
            VPI and NSAP represents the local 
            end point in this connection."
	::= { rpmChanGrpEntry 10 }
	
rpmChanLocalNsap OBJECT-TYPE
	SYNTAX 	   RpmNsapAddress
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object identifies the local NSAP address.

              The bytes are mapped as follows:
                 prefix    : 13 bytes
                 Cisco ID  : 2 bytes
                 Reserved  : 2 bytes
                 Slot/Port : 2 bytes[5 bit slot, 11 bits port]
                 Selector  : 1 byte.

             Of the 13 bytes for the node name, only the first 
             8 bytes are used. If the node name is n 
             (0 < n < 8) bytes long, the node name must be left 
             justified ( Bytes 1 to n contain the node name
             and bytes (n+1) to 8 must be 0 ). 
             Bytes 9-13 must be always 0."
	::= { rpmChanGrpEntry 11 }

rpmChanRemoteVpi OBJECT-TYPE
	SYNTAX 	   Integer32 (0..255)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This VPI together with the remote 
            VCI and NSAP represents the remote 
            end point in this connection."
	::= { rpmChanGrpEntry 12 }

rpmChanRemoteVci OBJECT-TYPE
	SYNTAX     Integer32 (0..65535)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This VCI together with the remote 
            VPI and NSAP represents the remote 
            end point in this connection."
	::= { rpmChanGrpEntry 13 }

rpmChanRemoteNsap OBJECT-TYPE
	SYNTAX 	   RpmNsapAddress
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object identifies the remote NSAP address.

              The bytes are mapped as follows:
                 prefix    : 13 bytes
                 Cisco ID  : 2 bytes
                 Reserved  : 2 bytes
                 Slot/Port : 2 bytes[5 bit slot, 11 bits port]
                 Selector  : 1 byte."
	::= { rpmChanGrpEntry 14 }

rpmChanType OBJECT-TYPE
	SYNTAX 	INTEGER {
                   svc(1),
                   pvc(2),
                   spvc(3)
                }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object identifies the channel type
              
             svc(1)  : Switched Virtual Connection
             pvc(2)  : Permanent Virtual Connection
             spvc(3) : Soft PVC."
	::= { rpmChanGrpEntry 15 }

rpmChanConnType OBJECT-TYPE
	SYNTAX 	INTEGER {
                    vpc(1),
                    vcc(2)
                }         
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This specifies the connection type
             vpc(1) : Virtual Path Connection
             vcc(1) : Virtual Channel Connection"
	::= { rpmChanGrpEntry 16 }

rpmChanServiceType OBJECT-TYPE
	SYNTAX 	INTEGER {
                    cbr    (1),
                    vbr    (2),
                    ubr    (4),
		    atfr   (5),
		    abrstd (6),
		    abrfst (7)
    }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	"This object identifies the connection service type.

           cbr    (1) : Constant Bit Rate
           vbr    (2) : Variable Bit Rate
           ubr    (4) : Unspecified Bit Rate
           atfr   (5) : ATM Frame Relay
	   abrstd (6) : Standard ABR
	   abrfst (7) : foresight ABR."
	::= { rpmChanGrpEntry 17 }

rpmChanMastership OBJECT-TYPE
	SYNTAX 	INTEGER {
                    master  (1),
                    slave   (2),
	            unknown (3)
                }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This specifies which end of the connection 
            is the master. This is used by PXM to determine 
            if this end point is master or slave."
	::= { rpmChanGrpEntry 18 }

rpmChanRtePriority OBJECT-TYPE
	SYNTAX 	   Integer32 (1..15)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is also known as class of service, 
            it is used by PXM to determine how important 
            this connection is when selecting connections 
            to route."
	::= { rpmChanGrpEntry 19 }

rpmChanMaxCost OBJECT-TYPE
	SYNTAX 	   Integer32 (1..65535)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Maximum allowed cost. It is related to 
            Cost Based Routing. This is used by PXM so 
            that it won't choose a path with a cost 
            greater than this configured level."
	::= { rpmChanGrpEntry 20 }

rpmChanRestrictTrkType OBJECT-TYPE
	SYNTAX 	INTEGER {
                    noRestriction    (1),
                    terrestrialTrunk (2),
                    satelliteTrunk   (3)
                }
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Restricted trunk type for routing, used by PXM.
            It specifies that the connection either cannot 
            be routed over satellite trunks or terrestrial
            trunks, or it can be on any type of trunk."
	::= { rpmChanGrpEntry 21 }

rpmChanPCR OBJECT-TYPE
	SYNTAX 	   Integer32  (0..353208)
        UNITS      "cells-per-second"
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Peak cell rate.(in cells per sec.)"
	::= { rpmChanGrpEntry 22 }

rpmChanRemotePCR OBJECT-TYPE
	SYNTAX 	   Integer32 (0..353208)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Peak cell rate of the remote endpoint of
            the connection. If not set, its value will
            be same as the value of rpmChanPCR."
	::= { rpmChanGrpEntry 23 }

rpmChanMCR OBJECT-TYPE
	SYNTAX 	   Integer32  (0..353208)
        UNITS      "cells-per-second"
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Minimum cell rate.(in cells per sec.)."
	::= { rpmChanGrpEntry 24 }

rpmChanRemoteMCR OBJECT-TYPE
	SYNTAX 	   Integer32 (0..353208)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Minimum cell rate of the remote endpoint. 
            If this is not set, its value will be same
            as value of rpmChanMCR."
	::= { rpmChanGrpEntry 25 }

rpmChanPercentUtil OBJECT-TYPE
	SYNTAX 	   Integer32 ( 0..100 )
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is the expected long-term utilization of the
    	    channel by this end-point."
	::= { rpmChanGrpEntry 26 }

rpmChanRemotePercentUtil OBJECT-TYPE
	SYNTAX 	   Integer32 ( 0..100 )
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is the expected long-term utilization of the
	    channel by the other end-point. If this is not 
            specified in the connection setup request, 
            it'll be set to be the same as the local end."
	::= { rpmChanGrpEntry 27 }

rpmChanEncapType OBJECT-TYPE
	SYNTAX 	INTEGER {
		    aal5snap(1),
		    aal34smds(2),
		    aal5nlpid(3),
		    qsaal(4),
	            ilmi(5),
		    aal5muxXNS(6),
	            aal5muxIP(7),
		    aal5muxVINES(8),
	            aal5muxDECNET(9),
		    aal5muxNOVELL1(10),
		    ppp(11),
		    unknown(12)
	        } 
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object identifies the ATM adaptation 
            layer (AAL) and Encapsulation type.

		aal5snap - LLC/SNAP precedes the protocol datagram.
		aal34smds - Encapsulation for SMDS network.
		aal5nlpid - Encapsulation that allows ATM interfaces  to
		            interoperate with HSSI.
		qsaal - signaling type PVC used  for setting up or 
		        tearing down SVCs.
		ilmi - used to set up communication with ILMI.
		aal5mux[protocol] - a MUX-type Virtual circuit.
		ppp - PPP over ATM.

             The Encapsulation types aal34smds, qsaal and ilmi 
             are not supported."
	::= { rpmChanGrpEntry 28 }

rpmChanMidLow OBJECT-TYPE
	SYNTAX 	   Integer32 (0..1023)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Starting Message Identifier Number for this PVC."
	::= { rpmChanGrpEntry 29 }

rpmChanMidHigh OBJECT-TYPE
	SYNTAX 	   Integer32 (0..1023)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Ending Message Identifier Number for this PVC."
	::= { rpmChanGrpEntry 30 }

rpmChanBurstSize OBJECT-TYPE
	SYNTAX 	   Integer32 (0..65535)
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "The Maximum number of ATM cells the 
            virtual circuit can transmit."
	::= { rpmChanGrpEntry 31 }

rpmChanInArpFreq OBJECT-TYPE
	SYNTAX 	   Integer32 (0..60)
        UNITS      "minutes"
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Specifies how often Inverse ARP datagrams
            will be sent on this virtual circuit. The
            value zero will disable the IN-ARP for this
            channel. This object is supported only
            for the value of rpmChanEncapType = aal5snap."
	::= { rpmChanGrpEntry 32 }

rpmChanOAMloopback OBJECT-TYPE
	SYNTAX 	   Integer32 (0..600) 
        UNITS      "seconds"
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This object specifies how often to generate 
            an OAM F5 loopback cell from this virtual circuit.
            The value zero will disable generation of OAM F5
            loopback cells."
	::= { rpmChanGrpEntry 33 }

rpmChanState  OBJECT-TYPE
    SYNTAX  INTEGER {
                notConfigured (1),
                active        (2),
                failed        (3)
               }
    MAX-ACCESS read-only
    STATUS     current
    DESCRIPTION
	"This indicates the status of this channel.
		1 ==> notConfigured
		2 ==> active
		3 ==> failed.

		Currently 'failed' state is not supported.
		When the channel is not added, the state is 
		notConfigured."
	::= { rpmChanGrpEntry 34 }

rpmChanVirtualTemplate OBJECT-TYPE
	SYNTAX     Integer32
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "Specifies the Virtual Template used for CISCO PPP.
	    If it is not using Virtual Template then this value
	    is zero."
	::= { rpmChanGrpEntry 35 }

rpmChanAbrRDF	OBJECT-TYPE
	SYNTAX     Integer32 
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is valid only for ABR Service Type.
	     Rate Decrease Factor: Controls the rate 
             decrease which occurs when backward RM-cells 
             with CI=1 are received. Larger values lead to 
             faster rate decrease."
         REFERENCE
             "ATM Forum Traffic Management Specification
	     Version 4.0 Section 5.10.2"
	::= { rpmChanGrpEntry 36 }

rpmChanAbrRIF	OBJECT-TYPE
	SYNTAX     Integer32 
	MAX-ACCESS read-only
	STATUS     current
	DESCRIPTION
	    "This is valid only for ABR Service Type.
	     Rate Increase Factor: Controls the rate 
             increase which occurs when a backward RM-cell 
             is received with CI=0 and NI=0. Larger values 
             lead to faster rate increase."
         REFERENCE
             "ATM Forum Traffic Management Specification
	     Version 4.0 Section 5.10.2"
	::= { rpmChanGrpEntry 37 }

-- conformance information

cmrConnMIBConformance
		OBJECT IDENTIFIER ::= { ciscoMgx82xxRpmConnMIB 2 }
cmrConnMIBCompliances
		OBJECT IDENTIFIER ::= { cmrConnMIBConformance 1 }
cmrConnMIBGroups
		OBJECT IDENTIFIER ::= { cmrConnMIBConformance 2 }


-- compliance statements

cmrConnMIBCompliance MODULE-COMPLIANCE
	STATUS	current
	DESCRIPTION
	    "The compliance statement for the 
            Cisco MGX RPM connection management group."
	MODULE  -- this module
	MANDATORY-GROUPS { cmrConnConfGroup }
	::= { cmrConnMIBCompliances 1 }

-- units of conformance

cmrConnConfGroup	OBJECT-GROUP
	OBJECTS { 
	    rpmChanSlotNum,
    	    rpmChanInterface,
	    rpmChanNum,
	    rpmChanRowStatus,
	    rpmChanVcd,
	    rpmChanVpi,
	    rpmChanVci,
	    rpmChanSubInterface,
	    rpmChanLocalVpi,
	    rpmChanLocalVci,
	    rpmChanLocalNsap,
	
	    rpmChanRemoteVpi,
	    rpmChanRemoteVci,
	    rpmChanRemoteNsap,

	    rpmChanType,
	    rpmChanConnType,
	    rpmChanServiceType,

	    rpmChanMastership,
	    rpmChanRtePriority,
	    rpmChanMaxCost,
	    rpmChanRestrictTrkType,

	    rpmChanPCR,
	    rpmChanRemotePCR,
	    rpmChanMCR,
	    rpmChanRemoteMCR,
	    rpmChanPercentUtil,
	    rpmChanRemotePercentUtil,

	    rpmChanMidLow,
	    rpmChanMidHigh,
	    rpmChanBurstSize,
	    rpmChanEncapType,
	    rpmChanInArpFreq,
	    rpmChanOAMloopback,
	    rpmChanState,
	    rpmChanVirtualTemplate,
	    rpmChanAbrRDF,
	    rpmChanAbrRIF
	}
	STATUS	current
	DESCRIPTION
	    "The objects related to Connections on RPM 
            card."
	::= { cmrConnMIBGroups 1 }